Skip to the manual
GeoTerva Start free
User manual · Stresses in a soil mass

Vertical strip load stresses: user manual

Calculate the vertical stress increase at a point below one or several flexible strip loads of finite width and infinite length: the stress at A, the lines of equal stress, colour contours, the profile with depth and a 3D view. This manual walks through the screen, dragging, every input, the results and the report, with a worked example you can reproduce.

Updated 17 October 2026 · GeoTerva user manual

What the module calculates

Vertical strip load gives the increase in vertical stress at a point of the ground below one or several flexible strips of finite width and infinite length, each carrying a uniform pressure q on the ground surface. The ground is taken as a homogeneous, isotropic, elastic half-space, and the problem is plane strain: the stress is the same in every cross section along the strip. You choose the point A by its horizontal position x and its depth z, and the module gives Δσz there, the lines of equal stress, the colour contours, the profile with depth under A and a 3D view.

For one strip of width B the stress at depth z and horizontal distance x from its centre line is found by integrating the line-load solution across the width of the strip:

Δσz = (q/π) {α − Bz[x² − z² − B²/4] / ([x² + z² − B²/4]² + B²z²)}

where α = θ₁ − θ₂ is the angle the strip subtends at A, and θ₁ and θ₂ are the angles the lines from A to the two edges of the strip make with the ground surface. The stress depends on x/B and z/B only, so the result is also given as the influence value Δσz/q. With several strips the stress of each is found with its own distance from A, and the stresses are added.

What you can describe

  • One to eight strip loads, each with its own load per unit area q, width B and position xc of its centre line along the x axis.
  • The point A: its horizontal position x on the same axis and its depth z below the surface.
  • The depth of the profile zmax, down to which the Profile view and the table under A run.

The result is the increase caused by the strips only; the overburden pressure of the soil above A is not included, so add it to the answer where your design needs the total stress. The module draws the section with the lines of equal stress, colour contours, the profile and a 3D view, writes out the working and prepares a PDF or Word report.

Which module for which load

Before you start: what you need

Have these ready from your design:

WhatNotes
The load per unit area q
Your design loading
The pressure the strip puts on the ground, zero or more. It is a pressure, not a force per metre of strip.
The width B
The footing, road or fill
The width of the loaded band, at least 0.001 m. The strip is taken as infinitely long.
The position xc
The layout
The place of the centre line along the x axis. With one strip you can leave it at 0 and measure x from its centre line.
The point A: x and z
Where you want the stress
x on the same axis as the centre lines; z at least 0.001 m below the surface.

Quick start in seven steps

  1. Open the module and choose the units

    Open Vertical strip load from the Stresses in a Soil Mass family. Pick SI · kN, SI · tf or US in the header; you can change it at any time.

  2. Enter the strip

    In Strip loads the first strip is already in the table. Press its row to change q, B and xc; or drag the strip on the Section drawing. To add another strip, fill the New strip load form and press + Add strip load.

  3. Place the point A

    In Point A type x and z, or drag the blue point on the Section drawing.

  4. Set the depth of the profile

    In Depth profile type zmax, or drag the dashed line at the foot of the Section drawing.

  5. Press Analyze

    Press Analyze at the foot of the Model tab. The bar reads Analysed and the strips lock; the point A and the profile depth stay free.

  6. Read the answer

    The Results tab gives Δσz at A, the influence value Δσz/q for one strip, the part from each strip for several, and a table of the stress against depth under A. The lines of equal stress are on the Section drawing, the colour bands in Contours.

  7. Move A and take the report

    Drag A or change x and z: the stress there is calculated at once. The Calculations tab writes out the working; the Report tab saves a PDF or a Word file.

The screen: section, contours, profile and 3D

The layout is the one every GeoTerva module shares, described in the workspace guide. For this module the drawing has four views, chosen with the buttons above it:

  • Section is the cross section of the strip or strips on the ground, with the point A, the dimensions x and z and the dashed line of the profile depth. After Analyze it adds the lines of equal stress and a label with Δσz at A.
  • Contours is the same section filled with colour bands of Δσz on a logarithmic scale, with a legend in kPa and in per cent of q.
  • Profile is the curve of Δσz against depth under A, with a marker at the depth of A.
  • 3D is an oblique view of the strip on the ground, the axes x, y and z, and a small element at A with the stress on it.

Before Analyze the drawings follow the inputs and say “The stress and the lines of equal stress appear after Analyze” (Section), “The colour contours of the stress appear after Analyze” (Contours) or “The profile appears after Analyze”.

The Section view before Analyze: the Show bar with Lines of equal stress unchecked and Dimensions checked, the strip of 100 kPa on the ground, the point A with its distances x = 1.00 m and z = 1.00 m, and the dashed line of the profile depth.
Section before Analyze.
The Section view after Analyze: the strip with the lines of equal stress labelled 90, 70, 50, 30 and 15 kPa, the point A with the label Δσz = 90.22 kPa and the line through A drawn in blue.
Section after Analyze: the lines of equal stress; the blue line is the value at A.
The Contours view after Analyze: colour bands from dark red under the strip to blue at the edges, a legend from 1 to 100 kPa, the point A and the dashed line of the profile depth.
Contours after Analyze.
The Profile view after Analyze: the curve of the stress increase falling from 100 kPa at the surface to about 20 kPa at 12 m, with the point A at 90.22 kPa and a dashed line at z = 1.00 m.
Profile after Analyze.
The 3D view after Analyze: the strip loaded with red arrows on the ground, the axes x, y and z, and an element at A with the stress Δσz = 90.22 on it.
3D after Analyze.

The Show chips

Above the Section and the Contours drawings a bar has two chips: Lines of equal stress and Dimensions. In the Section view the lines chip is off and greyed out until you press Analyze, and then turns on; in Contours it is off by default, so that the lines can be laid over the colours. Dimensions, the second chip, is on by default in both; it shows or hides the dashed axis of the load, the arrow with the distance x and the dashed line with the depth z (A and the profile-depth line stay). The Profile and 3D views have no chips.

Dragging on the drawing

Before Analyze the hint under the Section drawing has two lines: “Drag a load to move it, the rings at its edges to resize it. Drag the dashed line to set the depth of the profile (zmax).” and “Drag the point A to place it. The stress and the lines of equal stress appear after Analyze.” After Analyze only “Drag the dashed line to set the depth of the profile (zmax).” remains. What each pull does, as the module runs it:

  • The strip. Drag its body to move it: xc follows the pointer in steps of 5 cm. Pulling the strip 2 m to the right changes xc from 0 to 2.
  • An edge ring. Drag the ring at an edge to change the width: the edge you pull follows the pointer and the other edge stays where it is, so B and xc change together. Pulling the right ring 1 m to the right gives B = 5 and xc = 0.5; pulling the left ring 1 m to the left gives B = 5 and xc = −0.5. The width stops at 0.1 m.
  • Two strips never overlap. A pull that would put a strip on another stops at the last free place and a message says “That would put strip load 1 and strip load 2 on top of one another — the value is kept as it was.” Edges that meet are allowed.
  • The point A. Drag the blue point: x and z follow in steps of 5 cm. The depth stops at 0.05 m at the top and at the foot of the drawn frame at the bottom, and x at the sides of the frame. With the example, pulling A far to the upper left gives x = −7.2 m and z = 0.05 m, and far to the lower right x = 7.2 m and z = 8 m.
  • The dashed line. Drag it up or down to set zmax; it stops at 0.5 m.
  • After Analyze the strips are locked: pulling them changes nothing. The point A and the dashed line stay free, and so do the boxes x, z and zmax.

The 3D view has its own hint, “Drag a load over the ground to move it, the rings at its edges to resize it.” These pulls, like those of the Section view, work before Analyze only.

Zoom

Each view has −, a percentage and + at the lower right, and a button that fits the whole drawing in the pane. Zoom is a property of the drawing only: it is not saved with the model and does not change the report.

Entering the model, section by section

The Model tab has four sections: Model data, Strip loads, Point A and Depth profile. Each opens when you click its title; Next and Back at the foot walk you through them, and Analyze waits below the last one. Where a unit is shown twice or three times, such as m · ft, the units are those of SI · kN, SI · tf and US in turn, and equal ones are merged. Defaults are shown in SI; in US the boxes show the converted values, for example 13.1234 ft for the 4 m strip.

Model data

The first section holds the model name, Save to file…, Open file…, Quick Save… with its list and Load and Delete, and Reset to defaults. It works as described in the workspace guide.

The Model data section with the model name, Save to file, Open file, Quick Save, Reset to defaults and the quick-save list with Load and Delete.
Model data.

Strip loads

The section is a form over a table. The New strip load form takes q, B and xc; + Add strip load puts the strip into the Strip loads table, and a counter beside the button shows how many of the eight strips there are. The table lists each strip with its load, width and position. Press a row to change that strip in the form (the form then reads Editing · Strip load 1 and offers Done and Delete strip load; the note says that changes apply as they are entered), or press × to take a strip out. The first strip is already in the table when the module opens, and Delete strip load and × are greyed out while it is the only one.

The Strip loads section: the New strip load form with q = 100 kPa, B = 4 m and xc = 6 m, the Add strip load button with the counter 1 of 8, and the table with Strip load 1.
Strip loads: the form over the table.
Strip load fields (the form, and each row of the table)
FieldWhat to enter
Load per unit area q
kPa · t/m² · ksf · default 100
The uniform pressure of the strip on the ground. Zero or more.
Width of the strip B
m · ft · default 4
At least 0.001 m. The strip is infinitely long.
Position of the centre line xc
m · ft · default 0 (strip 1) · 6 (form)
Along the x axis. The New strip load form opens with 6 and keeps the last value after each Add; after deleting strip 1 of 2 the remaining strip is renumbered Strip load 1 and keeps its xc.
The Strip loads section with the row of strip 1 pressed: the form reads Editing, Strip load 1, shows q, B and xc with the Done and Delete strip load buttons.
A row of the table pressed: the strip is edited in the form.

The strips may not lie on top of one another: two strips may meet at an edge but not overlap. Adding or editing a strip that would overlap another is refused (see Messages). The strips are listed in the order you add them, and their numbers name the results “From strip load 1”, “From strip load 2” and so on.

The Strip loads section with two strips in the table: Strip load 1 with q = 100 kPa, B = 4 m and xc = 0 m, and Strip load 2 with q = 50 kPa, B = 4 m and xc = 6 m; the counter reads 2 of 8.
Two strips in the table.

Point A

The two coordinates of the point where you want the stress. A is under the ground surface at the horizontal position x and the depth z; the drawing shows the same distances as dimensions. The note in the section says that the stress of a strip is the same at equal distances either side of its centre line.

The Point A section with the horizontal position x = 1 m and the depth z = 1 m.
Point A.
Point A fields
FieldWhat to enter
Horizontal position of the point A x
m · ft · default 1
On the same axis as the centre lines. For one strip centred at 0 it is the distance from the centre line, and the stress is the same at equal distances either side.
Depth of the point A z
m · ft · default 1
At least 0.001 m below the ground surface.

Depth profile

The depth down to which the Profile view and the table of the stress under A run.

The Depth profile section with the depth of the profile zmax = 12 m.
Depth profile.
Depth profile field
FieldWhat to enter
Depth of the profile zmax
m · ft · default 12
At least 0.1 m. The table under A goes down to this depth, or to the depth of A if that is deeper; the Profile view goes to this depth, or to 1.2 times the depth of A if that is deeper.

Several strips and how they combine

The one choice in the module is how many strips there are, from 1 to 8; you make it by adding or deleting strips. The stress of each strip is found as if it were alone, with the distance x − xc of A from its centre line, and the stresses are added. This works because the ground is elastic, so the stresses of separate loads add.

  • Position is measured along one axis. x and every xc are on the same axis. A strip centred at xc = 3 with A at x = 1 gives the same stress as a strip centred at 0 with A at x = 2 (49.69 kPa in both runs), and a point at x = −1 gives the same as x = 1 (90.22 kPa).
  • Loads can differ. Each strip has its own q, so a road and a wider fill beside it can be put in one model.
  • The cards show the parts. The Results tab shows the total and the part from each strip, and the Calculations tab writes out each strip’s working.

With the example strip (100 kPa, 4 m, at 0) and A at x = 1 m, z = 1 m, a second strip of 100 kPa and 4 m centred at 6 m adds only 0.6320 kPa to the 90.22 kPa of the first: 90.86 kPa in all. If the second strip is 50 kPa, it adds 0.3160 kPa and the total is 90.54 kPa. A third strip of 100 kPa centred at 12 m brings the total to 90.87 kPa.

The Section view of two strips, q1 = 100 kPa and q2 = 50 kPa, with the lines of equal stress of the sum, one labelled 30, and the point A under the first strip with the label Δσz = 90.54 kPa.
Two strips, 100 kPa and 50 kPa: the lines of equal stress of the sum.
The Contours view of the same two strips: the colour bands of the sum, with a lower stress between the strips.
The same two strips in the Contours view.

Strips that meet

Two strips of 100 kPa and 4 m, one centred at 0 and one at 4 m, meet at the edge x = 2 m and together make one strip 8 m wide. With A at x = 2 m, z = 1 m, the edge, each strip gives 49.69 kPa and the total is 99.38 kPa. If the strips are 2 m apart (the second centred at 6 m) and A is at x = 3 m, the gap between them, each gives 8.923 kPa and the total is 17.85 kPa.

Which should I use?

  • One wide strip or several? One strip when the load is uniform across the whole width; several strips when the pressure or the width changes along the x axis, or when there are gaps.
  • A load that grows across its width is not several equal strips: use Triangular strip load.
  • A load of limited length is not a strip: use Rectangle. A strip is the right model when the length is several times the width.

Analyze and read the results

Press Analyze. The bar changes to Analysed — the stress at the point calculated and says “The inputs are locked. Edit inputs clears the results; the unit system can still be changed. The point A stays free: drag it on the drawing or change its coordinates, and the stress there is calculated at once.” A message appears briefly, “Analysed — see the Results tab and the Calculations.” The module stays on the Model tab: open Results for the answer. The Section view now shows the lines of equal stress.

The Analysed bar: Analysed — the stress at the point calculated, the message about the locked inputs and the free point A, the Warnings (0) button and the Edit inputs button.
The bar after Analyze.
The Results tab: the cards Vertical stress increase at A 90.22 kPa and Influence value 0.9022, with the note that the overburden pressure is not included.
The cards of the example.
CardSymbolThe example
Vertical stress increase at AΔσz90.22 kPa
Influence value (one strip)Δσz/q0.9022
From strip load k (two or three strips)Δσz(k)part of the total from strip k

Below the cards the Vertical stress increase under A table gives z, Δσz and, for one strip, Δσz/q at ten equal steps down to zmax (the first row is zmax/10), with the row of A inserted and highlighted. With several strips the ratio column is left out. A Values, step by step table above it lists the steps of the Calculations tab with their values.

The table Vertical stress increase under A with the columns z, Δσz and Δσz/q: 1.000 m 90.22 kPa 0.9022 highlighted, then 1.200, 2.400 and on to 12.00 m with 20.57 kPa and 0.2057.
The depth table of the example.
The Results tab of two strips: the total 90.54 kPa and the parts 90.22 kPa from strip load 1 and 0.3160 kPa from strip load 2.
Two strips: the total and the part from each.

Using the numbers

  • The result is an increase, not the total stress: add the overburden pressure of the soil above A for the total vertical stress.
  • The influence value Δσz/q is the part of the surface pressure that reaches A. It is 1 on the surface under the strip and falls with depth and with distance from the strip.
  • Values are rounded where they are drawn, so the last digit of a figure on the drawing can differ by one from the card.
  • Change x or z after Analyze and everything follows at once; to change a strip, press Edit inputs, which unlocks the strips and clears the results.
  • Changing the unit system after Analyze re-states the cards and the report without a new run. The drawings keep their labels in m and kPa.

Warnings and notes

The bar carries a Warnings (0) button. It opens a window that says “No warnings — the assumptions of the solution hold for these inputs.” The runs of this manual, from the default to eight strips, gave no warning.

The window Warnings (0) with the text No warnings — the assumptions of the solution hold for these inputs, and a Close button.
The Warnings window.

The Calculations tab, the report and the Theory tab

The Calculations tab opens with Given and what is sought and then writes out the working in numbered steps, ending with the answer. For one strip:

  1. The angles the strip subtends at A — B/2, 2x/B and 2z/B, the angles θ₁ and θ₂ with your numbers, and α = θ₁ − θ₂ in radians and degrees.
  2. Stress at A — the equation above, its arctangents and third term with your numbers, then Δσz/q and Δσz = Δσz/q × q.
  3. Stress increase against depth — the same equation down the vertical line through A, as the table of the Results tab, with the row of A marked.

With several strips there is one step for each strip, with its own distance x − xc, then a Superposition step that adds the parts, then the depth table.

The Calculations tab: the Given and what is sought block and step 1, the angles the strip subtends at A, with B/2 = 2.00 m, 2x/B = 0.5000, 2z/B = 0.5000, θ1 = 2.3562 rad, θ2 = 0.3218 rad and α = 2.0344 rad (116.57°).
The Calculations tab: the first steps with the example’s numbers.

The report

In the Report tab fill in the cover (project, location, client, report number, date, prepared by, title or qualification, checked by, and optional notes). The details are kept in this browser and saved with the model file. Save as PDF and Download Word (.docx) produce the summary report; the preview below the buttons is the report itself.

The report has six parts: 1 Introduction and scope, 2 Input data, 3 Calculation, 4 Results, 5 Summary and 6 References. It carries three drawings, the Section with the lines of equal stress, the Profile and the 3D view, and states the units used.

The Report tab: the cover form with project, location, client, report number, date, prepared by, title and checked by, the notes box, the Save as PDF and Download Word buttons, and the cover page of the report with the stress 90.22 kPa and the conclusion sentence.
The Report tab: the cover details, the two buttons and the first page.

The Theory tab

The Theory tab has six sections: Scope and assumptions, Derivation, The angle form, Pressure bulb and table, Worked example and References. Each opens when you click its title (Open all and Close all open or close them together), and the figures in it are computed from the equations.

Worked example: the module’s own example

The module opens on this example, so you can follow the numbers on your own screen.

Inputs of the example
SectionInputValue
Strip loadsStrip load 1q = 100 kPa; B = 4 m; xc = 0
Point APositionx = 1 m; z = 1 m
Depth profileDepthzmax = 12 m

Step 1: the angles

The edges of the strip are at ±2 m. Seen from A, the edge lines make the angles θ₁ = atan2(1, 1 − 2) = atan2(1, −1) = 2.3562 rad and θ₂ = atan2(1, 1 + 2) = 0.3218 rad, so α = θ₁ − θ₂ = 2.0344 rad (116.57°). Also 2x/B = 0.5 and 2z/B = 0.5.

Step 2: the stress

The third term is Bz[x² − z² − B²/4] / ([x² + z² − B²/4]² + B²z²) = 4 × 1 × (1 − 1 − 4) / ((1 + 1 − 4)² + 16) = −16/20 = −0.8000.

Δσz/q = (2.0344 + 0.8000)/π = 0.9022, Δσz = 0.9022 × 100 = 90.22 kPa

These are the two cards of the Results tab and the steps of the Calculations tab. The same equation at the depths of the table gives the profile: the module’s table gives 90.22 kPa at 1 m, 86.63 kPa at 1.2 m and 20.57 kPa at 12 m, and the same equation worked independently gives the same three values.

Other unit systems

The same strip in SI · tf, with q = 10 t/m² (the other values unchanged), gives 9.022 t/m² and the influence value 0.9022. In US the default example, which is 2.089 ksf on a strip 13.12 ft wide, gives 1.884 ksf: 90.22 kPa is 1.884 ksf. A check by hand with round US numbers: q = 2 ksf, B = 10 ft, A at x = 2.5 ft, z = 2.5 ft gives 2x/B = 2z/B = 0.5, the same ratio 0.9022, so Δσz = 0.9022 × 2 = 1.804 ksf; the module gives 1.804 ksf.

How each input changes the answer

Each row changes one thing in the example (one strip of q = 100 kPa, B = 4 m, xc = 0, A at x = 1 m, z = 1 m) and runs the module again, in SI · kN. The numbers are the ones the module gives, so you can reproduce any row; an independent calculation with the same equation agrees with every row.

The example with one change at a time
ChangeΔσz (kPa)Δσz/q
The example90.220.9022
q = 200 kPa
The stress is proportional to the load; the ratio is unchanged
180.40.9022
q = 50 kPa
Half the load, half the stress
45.110.9022
B = 2 m
A narrower strip puts less on the same point
47.970.4797
B = 8 m
A wider strip: A is deeper inside the loaded width and the stress rises
99.150.9915
B = 20 m
Nearly an infinite loaded width: the ratio approaches 1
99.960.9996
x = 0 (under the centre line)
The highest stress of the section at this depth
95.950.9595
x = −1 m
The same as x = +1 m: the stress is symmetric about the centre line
90.220.9022
x = 2 m (under the edge)
About half of q (0.497 q) at 1 m depth
49.690.4969
x = 4 m (2 m beside the edge)
The stress falls to about 2 per cent of the load
1.9310.01931
x = 10 m
Far from the strip the stress is a tiny part of the load
0.028500.0002850
z = 0.5 m
Near the surface the stress approaches q
97.880.9788
z = 0.01 m
At the surface under the strip the stress equals q
100.01.000
z = 2 m
The stress falls with depth
73.470.7347
z = 4 m
About half of q at one strip width of depth
51.050.5105
z = 8 m
At twice the strip width, under 30 per cent of q
29.760.2976
xc = 3 m (A at x = 1 m)
A is 2 m from the centre line: the same as x = 2 with the strip at 0
49.690.4969
x = 2 m and z = 2 m
The same 2x/B and 2z/B as B = 2 m with A at (1 m, 1 m): the same stress
47.970.4797

Several strips, SI · kN, one change at a time from the example (second strip added with the values shown):

Adding strips
AddedTotal (kPa)Parts (kPa)
Strip 2: 100 kPa, 4 m, centre at 6 m
A at (1 m, 1 m); the gap between the strips is 2 m (edges at x = 2 m and x = 4 m)
90.8690.22 + 0.6320
Strip 2: 50 kPa, 4 m, centre at 6 m
A at (1 m, 1 m)
90.5490.22 + 0.3160
Strip 2: 100 kPa, 4 m, centre at 4 m
The strips meet at x = 2 m; A at (2 m, 1 m)
99.3849.69 + 49.69
Strip 2: 100 kPa, 4 m, centre at 6 m
A at (3 m, 1 m), in the gap
17.858.923 + 8.923

The pattern follows the equation. The stress is proportional to q; it depends on x/B and z/B only, so doubling every length leaves the ratio unchanged; it is highest under the centre line and falls with depth and with distance from the strip; and with z near zero it equals q under the strip and zero beside it. The depth of the profile zmax changes the table and the Profile view but not the stress at A: 90.22 kPa with zmax = 6 m and 90.22 kPa with zmax = 0.5 m, a depth to which the table is extended, down to the depth of A.

Messages: when the module stops, and what it notes

The module checks the numbers it needs before it calculates. When an input cannot be used, press Analyze and a window titled Cannot analyse — 1 input error (or 2 input errors …) lists each message and the box of the value is marked in red; nothing is calculated.

The window Cannot analyse, 1 input error: Width of strip 1 (B1) must be at least 0.001 m.
The window Analyze opens when the width is zero.
WhenMessage and what to do
B is 0“Width of strip 1 (B1) must be at least 0.001 m.” Enter a width of at least 0.001 m.
q is negative“Load per unit area of strip 1 (q1) must be at least 0 kPa.” Enter zero or a positive load.
z is 0“Depth of the point A (z) must be at least 0.001 m.” Enter a depth of at least 0.001 m.
zmax is 0“Depth of the profile (zmax) must be at least 0.1 m.” Enter a depth of at least 0.1 m.
A box is empty“Width of strip 1 (B1) is missing.” Fill the box or take the strip out.
A new strip would overlap anotherA message appears briefly: “The new strip load would lie on strip load 1 — they cannot overlap. Give it another position or width.” The strip is not added.

The messages use the numbered names of the strips, such as “strip 1” and “B1”, even when there is only one strip, and the limits in the units of the unit system chosen. When you type a position or width into a strip already in the table and it would put two strips on one another, a message appears briefly: “That would put strip load 1 and strip load 2 on top of one another — the value is kept as it was.” and the value stays as it was. At eight strips + Add strip load is greyed out and the counter reads 8 of 8.

Notes and warnings

With every input inside its limits the module calculates, and the Warnings window reads “No warnings — the assumptions of the solution hold for these inputs.” A load of zero is accepted and gives 0 kPa, with a dash for the influence value. Large values are accepted too: a very wide strip such as B = 1000 m is a load that is nearly infinite in width, and with q = 1,000,000 kPa the module gives 1,000,000 kPa at A, an influence value of 1.000.

Good practice and common mistakes

  • Use the module for a long, uniformly loaded band. The strip is infinitely long and flexible, so the pressure stays q across the width. A footing that is stiff will distribute its pressure differently; the module gives the stress for the pressure you enter.
  • Enter a pressure, not a force. q is a load per unit area. A line load per metre of strip is q × B; if the width is small compared with the depth, Vertical line load is the closer model.
  • Mind the axis. x and every xc are on the same axis; the stress of a strip depends on the distance x − xc, so a point left of a strip gives the same as one the same distance right of it.
  • Do not overlap strips. Strips may meet at an edge but not lie on one another; to describe a stepped load, split it into strips that meet.
  • Add the overburden. The result is the stress increase; for the total vertical stress add the soil weight above A.
  • Read the profile with the depth of the strip’s width in mind. Under the centre line of a 4 m strip the stress is 55 per cent of q at 4 m depth, one strip width, and 31 per cent at 8 m, twice the width.
  • Place A with the drawing, then type exact values. Dragging snaps to 5 cm; type the coordinates when you need a given place.
  • Check the units after switching the system: type values in the units shown beside the boxes.
  • Keep a record. The report is the record of an analysis; use Quick Save… or Save to file… to keep the model.

Frequently asked questions

How is the stress below a strip load calculated?

The module integrates the line-load solution of the theory of elasticity across the width of the strip. For a strip of width B and pressure q, the vertical stress increase at the horizontal distance x from its centre line and the depth z is Δσz = (q/π){α − Bz[x² − z² − B²/4]/([x² + z² − B²/4]² + B²z²)}, with α the angle the strip subtends at A. For the module’s example it gives 90.22 kPa.

What is the influence value Δσz/q?

It is the stress increase divided by the strip pressure. It depends only on x/B and z/B, is 1 at the surface under the strip, and is the number to use if you have a table of influence values. The module gives it for one strip; with several strips it gives the stress of each.

Does the result include the weight of the soil?

No. It is the increase caused by the strips only. Add the overburden pressure of the soil above A for the total vertical stress.

How many strips can I add, and can they overlap?

Up to eight, each with its own q, B and xc. They may meet at an edge but not overlap; the module refuses a strip that would lie on another. The stresses of the strips add.

Can I drag the strip and the point on the drawing?

Yes. Drag the strip body to move it, the rings at its edges to change its width, the blue point to place A and the dashed line to set the depth of the profile; they move in 5 cm steps. After Analyze the strips are locked, but A and the dashed line stay free.

What does the point A depend on?

On x, along the same axis as the centre lines, and on z, its depth. The stress of a strip is the same at equal distances either side of its centre line.

What do the lines of equal stress show?

Each line joins the points of the section with the same Δσz, labelled in kPa; the blue line is the value at A. Switch them on and off with the Lines of equal stress chip. The Contours view shows the same stress as colour bands on a logarithmic scale.

What values does the module accept?

q zero or more, B at least 0.001 m, z at least 0.001 m, zmax at least 0.1 m, and x and xc any value. Anything else stops the analysis with a message that names the value.

Which units does it use, and what are the units of the answer?

SI · kN, SI · tf or US, switchable in the header at any time, even after Analyze. Stresses are in kPa, t/m² or ksf and lengths in m or ft. The default example gives 90.22 kPa, 9.022 t/m² with q = 10 t/m², or 1.884 ksf.

What does the report contain?

A cover with your project details and the answer, then six parts: introduction and scope, input data, the calculation step by step, results, summary and references, with the section, profile and 3D drawings. It is saved as a PDF or a Word file once the model is analysed.

Does the module remember my inputs?

Yes. Every change is kept in the browser, and the page opens again on the model you last worked on, including its analysed state. Reset to defaults brings back the example; Save to file and Quick Save keep copies.

When is a strip the wrong model?

When the load is short compared with the depth you ask about, so that its ends matter: use Rectangle. When the pressure is not uniform across the width: use Triangular strip load, or split the load into strips of different q. When the load is horizontal: use Horizontal strip load.