Skip to the manual
GeoTerva Start free
User manual · Bearing capacity

Bearing capacity: the user manuals

Five modules give the load a shallow footing can carry before the ground fails under it, by the methods of Terzaghi, Meyerhof, Hansen and Vesic and for an earthquake. This page helps you choose the module that matches your footing and links to the manual of each.

Updated 17 October 2026 · GeoTerva user manual

Which bearing capacity module do I need?

The Bearing Capacity family has five modules. They answer one question: how much load can a shallow footing carry before the ground fails under it? They differ in the method and in the corrections they apply. Pick the one that matches your footing and your load.

Your questionModule
The classical bearing capacity equation, for a strip, square or circular footing, in general or local shearTerzaghi
The general equation for any footing shape and any depth-to-width ratio, with shape, depth and inclination factors printed with their numbersMeyerhof
A footing near a slope, on a tilted base, or under an inclined load, in one equationHansen
The same corrections by Vesic’s factors, with the inclination exponent taken from the footing’s own B/L and the direction of the loadVesic
A strip footing during an earthquake, with the horizontal seismic coefficient acting on the soilSeismic bearing capacity

The five manuals

Each manual follows the same plan: what the module calculates, what you need before you start, a quick start, the screen, every input, the factors and the choices, the results, the report, a worked example you can reproduce, a table of how each input changes the answer, the messages the module gives, and answers to common questions.

What the five modules share

  • The workspace. The drawing, the tabs, Analyze and the input lock, units and the report follow the same layout as the other GeoTerva modules. See the workspace guide.
  • The mechanism to scale. Each module draws the failure mechanism under your footing to scale.
  • The factors. Each module works out the bearing capacity factors and the corrections of its own method and prints them.
  • The result. The ultimate and the allowable bearing capacity, gross and net.
  • The check. You enter the applied pressure and the module checks it against the allowable value, with the verdict PASS or FAIL.
  • Groundwater. The water table can lie at any depth; the unit weights are adjusted for it.

The methods side by side

ModuleFooting and loadMethod
TerzaghiStrip, square or circular; general or local shearTerzaghi (1943), with Nγ after Kumbhojkar (1993)
MeyerhofStrip, square, rectangular or circular; vertical or inclined load; any depthMeyerhof (1963), De Beer shape factors, Hansen depth factors
HansenSloping ground, tilted base, inclined loadHansen (1970)
VesicAs Hansen, with the exponent m from B/LVesic (1973, 1975)
Seismic bearing capacityStrip footing in an earthquakeRichards, Elms and Budhu, by Coulomb wedges

A typical bearing capacity check in order

  1. Choose the method

    Decide whether you need the classical equation, the general equation with its corrections, the slope and tilt corrections, or the seismic case.

  2. Describe the footing and the soil

    Enter the footing shape and size, its depth, the strength and the unit weights of the soil and the water table.

  3. Enter the load and the safety factor

    Give the applied pressure, the load inclination where the module takes one, and the factor of safety.

  4. Analyze and read the verdict

    Press Analyze. Read the ultimate and allowable bearing capacity, the factors and the verdict, then save a report with the cover filled in.

Frequently asked questions

How do I calculate the bearing capacity of a shallow footing with GeoTerva?

Open the module for the method you use, for example Meyerhof. Enter the footing, the soil, the water table and the factor of safety, give the applied pressure, press Analyze, and read the ultimate and the allowable bearing capacity and the PASS or FAIL verdict.

Which method should I use?

Terzaghi gives the classical equation. Meyerhof takes any shape and depth and an inclined load. Hansen and Vesic add the corrections for sloping ground and a tilted base. Run two methods on the same footing and compare the results.

Which module gives the bearing capacity in an earthquake?

Seismic bearing capacity, by Richards, Elms and Budhu, for a strip footing, with the horizontal seismic coefficient acting on the soil.

Does the module show the factors it used?

Yes. Each module prints the bearing capacity factors and the corrections of its method with their numbers.

Can I include the water table?

Yes. The water table can lie at any depth and the unit weights are adjusted for it.

Do the modules give the gross and the net bearing capacity?

Yes. Each module gives the ultimate and the allowable bearing capacity, both gross and net.