Which bearing capacity module do I need?
The Bearing Capacity family has five modules. They answer one question: how much load can a shallow footing carry before the ground fails under it? They differ in the method and in the corrections they apply. Pick the one that matches your footing and your load.
| Your question | Module |
|---|---|
| The classical bearing capacity equation, for a strip, square or circular footing, in general or local shear | Terzaghi |
| The general equation for any footing shape and any depth-to-width ratio, with shape, depth and inclination factors printed with their numbers | Meyerhof |
| A footing near a slope, on a tilted base, or under an inclined load, in one equation | Hansen |
| The same corrections by Vesic’s factors, with the inclination exponent taken from the footing’s own B/L and the direction of the load | Vesic |
| A strip footing during an earthquake, with the horizontal seismic coefficient acting on the soil | Seismic bearing capacity |
The five manuals
Each manual follows the same plan: what the module calculates, what you need before you start, a quick start, the screen, every input, the factors and the choices, the results, the report, a worked example you can reproduce, a table of how each input changes the answer, the messages the module gives, and answers to common questions.
The methods side by side
| Module | Footing and load | Method |
|---|---|---|
| Terzaghi | Strip, square or circular; general or local shear | Terzaghi (1943), with Nγ after Kumbhojkar (1993) |
| Meyerhof | Strip, square, rectangular or circular; vertical or inclined load; any depth | Meyerhof (1963), De Beer shape factors, Hansen depth factors |
| Hansen | Sloping ground, tilted base, inclined load | Hansen (1970) |
| Vesic | As Hansen, with the exponent m from B/L | Vesic (1973, 1975) |
| Seismic bearing capacity | Strip footing in an earthquake | Richards, Elms and Budhu, by Coulomb wedges |
A typical bearing capacity check in order
- Choose the method
Decide whether you need the classical equation, the general equation with its corrections, the slope and tilt corrections, or the seismic case.
- Describe the footing and the soil
Enter the footing shape and size, its depth, the strength and the unit weights of the soil and the water table.
- Enter the load and the safety factor
Give the applied pressure, the load inclination where the module takes one, and the factor of safety.
- Analyze and read the verdict
Press Analyze. Read the ultimate and allowable bearing capacity, the factors and the verdict, then save a report with the cover filled in.
Frequently asked questions
How do I calculate the bearing capacity of a shallow footing with GeoTerva?
Open the module for the method you use, for example Meyerhof. Enter the footing, the soil, the water table and the factor of safety, give the applied pressure, press Analyze, and read the ultimate and the allowable bearing capacity and the PASS or FAIL verdict.
Which method should I use?
Terzaghi gives the classical equation. Meyerhof takes any shape and depth and an inclined load. Hansen and Vesic add the corrections for sloping ground and a tilted base. Run two methods on the same footing and compare the results.
Which module gives the bearing capacity in an earthquake?
Seismic bearing capacity, by Richards, Elms and Budhu, for a strip footing, with the horizontal seismic coefficient acting on the soil.
Does the module show the factors it used?
Yes. Each module prints the bearing capacity factors and the corrections of its method with their numbers.
Can I include the water table?
Yes. The water table can lie at any depth and the unit weights are adjusted for it.
Do the modules give the gross and the net bearing capacity?
Yes. Each module gives the ultimate and the allowable bearing capacity, both gross and net.