Skip to the manual
GeoTerva Start free
User manual · Bearing capacity

Meyerhof bearing capacity: user manual

Calculate the ultimate and the allowable bearing capacity of a shallow footing by Meyerhof’s general equation, with De Beer shape factors, Hansen depth factors and Meyerhof inclination factors, for a vertical or an inclined load and any water table. This manual walks through the screen, every input, the results and the report, with a worked example you can reproduce.

Updated 17 October 2026 · GeoTerva user manual

What the module calculates

Meyerhof gives the ultimate and the allowable bearing capacity of a shallow footing by Meyerhof’s general equation, for a strip, square, rectangular or circular footing at any depth, under a vertical or an inclined load. The module draws the failure mechanism to scale under the footing, works out the bearing capacity factors and the three corrections of the method, and gives the gross and the net ultimate capacity and the gross and the net allowable pressure. If you enter the applied pressure at the base, it checks it and answers PASS or FAIL.

qu = c Fcs Fcd Fci Nc + q Fqs Fqd Fqi Nq + ½ γ B Fγs Fγd Fγi Nγ

The factors come from closed forms, none from a table:

  • Nq = exp(π tan φ) tan²(45° + φ/2) and Nc = (Nq − 1) cot φ (Reissner, Prandtl; Meyerhof 1963), and Nγ = 2(Nq + 1) tan φ (Vesic 1973).
  • Shape factors of De Beer (1970), from the ratio B/L: Fcs = 1 + (B/L)(Nq/Nc), Fqs = 1 + (B/L) tan φ, Fγs = 1 − 0.4 B/L.
  • Depth factors of Hansen (1970): Fqd = 1 + 2 tan φ (1 − sin φ)² k and Fcd = Fqd − (1 − Fqd)/(Nc tan φ), with k = Df/B (or arctan(Df/B) in radians when Df/B is above 1); Fγd = 1. At φ = 0 the cohesion factor is 1 + 0.4 k.
  • Inclination factors of Meyerhof (1963): Fci = Fqi = (1 − β/90°)² and Fγi = (1 − β/φ)², which is 0 once β reaches φ.

Here q is the overburden at the base level and γ the unit weight in the self-weight term; both follow the groundwater you describe. The equation returns the vertical component of the ultimate load; the module also gives the allowable resultant load at the angle β.

Which module for which job

  • The same family has Terzaghi (general and local shear, vertical load), Hansen and Vesic (also a tilted base and sloping ground) and the seismic strip footing of Richards, Elms and Budhu. The family page compares them.
  • Use Meyerhof when the footing has any shape and depth and the load is vertical or inclined on level ground, and you want every factor printed with its numbers.
  • The stress the footing adds to the ground below, for settlement, is the job of Stresses in a soil mass.

Before you start: what you need

Have these ready from your design and your ground investigation:

WhatNotes
The footing
From: your design
The shape, the width B (the shorter side; the diameter of a circle), for a rectangle the length L, and the founding depth Df.
The soil under the footing
From: your ground investigation
The effective cohesion c, the friction angle φ and the unit weight γ above the water table. The module takes one soil for the whole footing.
The groundwater
From: the borings
Whether a water table is present, its depth Dw from the ground surface and the saturated unit weight γsat.
The load
From: your structural analysis
The inclination β of the load from the vertical. Optional: the vertical gross pressure at the base qapplied, which is V/A with service loads, including the weight of the footing and of the soil above it.
The factor of safety
From: your design basis
The module opens with 3.

Quick start in seven steps

  1. Open the module and choose the units

    Open Meyerhof from the Bearing Capacity family. Pick SI · kN, SI · tf or US in the header; you can change it at any time, also after Analyze.

  2. Describe the footing

    In Footing pick Strip, Square, Rectangular or Circular and type B (and L for a rectangle) and the depth Df.

  3. Enter the soil and the water

    In Soil type c, φ and γ. In Groundwater choose Present or None; if present, type γsat and the depth Dw.

  4. Enter the load

    In Loads type the inclination β (0 for a vertical load) and, if you have it, the applied pressure qapplied.

  5. Set the factor of safety

    In Analysis Settings type FS (at least 1).

  6. Press Analyze

    Press Analyze at the foot of the Model tab. The bar reads Analysed, the inputs lock, and the drawing switches to the Capacity view.

  7. Read the answer

    The Results tab gives qu, qu,net, qall,g and qall,n, the allowable load, and PASS or FAIL when you entered qapplied. The Calculations tab writes out every factor and the Report tab saves a PDF or a Word file.

The screen: section, capacity and factors

The layout is the one every GeoTerva module shares, described in the workspace guide. The drawing on the left has three views, chosen with the buttons above it, and the panel on the right has the tabs Model, Results, Calculations, Report and Theory.

  • Section is a cross section through the footing, drawn to scale: the footing with the load arrow at the angle β, the ground surface, the base level, the water table, the overburden q at the base, and Meyerhof’s failure mechanism for the φ you entered: I the elastic wedge under the footing at the base angle 45° + φ/2, II the radial shear zone bounded by a log spiral, and III the passive wedge at 45° − φ/2. Under the footing it shows qu once analysed. The drawing follows your inputs as you type.
  • Capacity is the view the module switches to when you press Analyze. It shows the three terms of qu (cohesion, surcharge, self-weight) as one bar, the gross pressures qu and qall,g, the net pressures qu,net and qall,n above the overburden, and all twelve factors with their values.
  • Factors plots Nc, Nq and Nγ against φ from 0° to 50° on a logarithmic scale, with a dashed line at your φ and the three values on it.
The Section view before Analyze: the footing, the water table, the load arrow inclined 10 degrees, the dimensions B and Df and the three zones of the failure mechanism drawn to scale for 32 degrees.
Section before Analyze: the geometry and the mechanism for the inputs.
The Section view after Analyze: the same drawing with qu = 520.0 kPa in a box under the footing.
Section after Analyze: the box under the footing gives qu.
The Capacity view: the bar of the three terms, the gross and net pressures and the twelve factors.
Capacity: the terms, the pressures and the factors.
The Factors view: the curves of Nc, Nq and Nγ against the friction angle on a logarithmic scale, with the dashed line at 32 degrees and the values Nc 35.49, Nγ 30.21 and Nq 23.18.
Factors: the three curves and your φ.

The Show chips

Above the Section a bar holds two chips, Failure mechanism and Dimensions, both on by default. The first draws the three zones and the second the dimension lines of B and Df; the water table, the load arrow and the labels stay when they are off. The small ? beside Show says that the drawing is display only. The Capacity and Factors views have no chips.

The Show bar with the two chips Failure mechanism and Dimensions switched on.
The Show bar.
The Section view with the chip Failure mechanism switched off: the mechanism is hidden; footing, water table, load, dimensions and qu stay.
Section with Failure mechanism off.
The Section view with the chip Dimensions switched off: no dimension lines of B and Df.
Section with Dimensions off.

Dragging and zoom

Nothing in the drawings can be dragged and the views have no zoom: the drawings follow the numbers you type. After Analyze the inputs are locked until you press Edit inputs, which also clears the results. The unit system can still be changed.

Entering the model, section by section

The Model tab has six sections: Model data, Footing, Soil, Groundwater, Loads and Analysis Settings. Model data opens and closes on its own; opening any of the other five sections closes the one that was open. On a fresh start Model data and Footing are open. Next and Back at the foot walk you through them, and Analyze waits at the bottom. In the tables, a unit shown more than once, such as kPa · kg/cm² · psf, gives the units of SI · kN, SI · tf and US in turn. Defaults are shown in SI. A value that is outside its range is refused when you press Analyze, see Messages.

Model data

The first section holds the model name, Save to file…, Open file…, Quick Save… with its list and Load and Delete, and Reset to defaults. It works as described in the workspace guide. Reset returns the example at once and the page keeps it as the model of the browser.

The Model data section with the model name box, Save to file, Open file, Quick Save, Reset to defaults and the quick-save list with Load and Delete.
Model data.

Footing

Choose the footing shape with the four buttons. B is the width, the shorter side (the diameter of a circle), and Df the depth of the base below the ground surface. Rectangular adds the length L, which must not be shorter than B. A strip is treated as plane strain (B/L = 0, every shape factor 1) and its loads are per metre of length; a square and a circle both use B/L = 1, so a circle of diameter B gives the same pressures as a square of side B (520.0 kPa in the example).

The Footing section with the shape Square chosen, the width 1.2 and the founding depth 1.
Footing: a square footing.
Footing fields
FieldUnitDefault
Footing shape
Strip, Square, Rectangular or Circular.
choiceSquare
Footing width (short side) B
At least 0.05 m.
m · m · ft1.2
Footing length (long side) L
Only for a rectangle; at least 0.05 m and not shorter than B.
m · m · ft1.2
Founding depth Df
At least 0 (a footing on the surface).
m · m · ft1
The Footing section with Rectangular chosen: the box Footing length (long side) appears under the width.
Footing with Rectangular: the length box appears.

Soil

One soil under the footing, described by three numbers. The note says that the soil below the footing is characterised by c, φ and γ. Use effective-stress parameters for a drained analysis.

The Soil section with cohesion 0, friction angle 32 and unit weight 16.
Soil.
Soil fields
FieldUnitDefault
Cohesion c
At least 0.
kPa · kg/cm² · psf0
Friction angle φ
From 0 to 50°. At 0 the module uses Nc = 5.14, Nq = 1 and Nγ = 0 (a clay under undrained loading).
°32
Unit weight (above GWT) γ
At least 0.1. Used for the soil above the water table, or everywhere when there is no water table.
kN/m³ · t/m³ · pcf16

Groundwater

Choose Present or None. With None the two water boxes are hidden and the unit weight γ is used everywhere. With Present enter the saturated unit weight and the depth of the water table from the ground surface. Three read-outs under the boxes follow your inputs: the surcharge q at the base, the water case (above the base, within B below the base, or deeper than B) and the ratio Df/B.

The Groundwater section: Present chosen, saturated unit weight 19.5, water table depth 0.5, and the read-outs surcharge 12.85 kPa, water case above the base and Df/B 0.83.
Groundwater with its three read-outs.
Groundwater fields
FieldUnitDefault
Water table
Present or None.
choicePresent
Saturated unit weight γsat
At least 0.1 and above the unit weight of water (9.81 kN/m³). Shown when the water table is present.
kN/m³ · t/m³ · pcf19.5
Water table depth Dw
At least 0, from the ground surface. Shown when the water table is present.
m · m · ft0.5

Loads

The inclination β of the load from the vertical, and the optional applied pressure. qapplied is the vertical gross pressure at the base: the vertical load of the column plus the weight of the footing and of the soil above it, divided by the base area (V/A, with service loads). With an inclined load enter the pressure of the vertical component, V/A, not the resultant Q/A. Leave it empty and the module gives the capacity; the Design check reads NOT CHECKED until you enter the pressure. The ? beside Applied load opens an explanation with a drawing.

The Loads section with the load inclination 10 and the empty optional box for the applied pressure, and the note on what the applied pressure is.
Loads.
Load fields
FieldUnitDefault
Load inclination from vertical β
From 0 to 89°. 0 is a vertical load.
°10
Applied vertical gross pressure at the base (optional) qapplied
At least 0 when given.
kPa · t/m² · ksfempty
The help window of the Loads section: the footing with the column load Q at the angle beta, the weights of the footing and of the soil on it, and the formulas of the gross and net checks.
The ? of the Loads section: what the applied pressure is.

Analysis Settings

One number, the factor of safety applied to the ultimate capacity.

The Analysis Settings section with the factor of safety 3.
Analysis Settings.
Analysis field
FieldUnitDefault
Factor of safety FS
At least 1.
—3

Choosing the shape, the water and the load

There is no method to choose: the equation is Meyerhof’s. What you decide is the footing, the water and the load.

ChoiceWhat it does
StripPlane strain: B/L = 0, so Fcs = Fqs = Fγs = 1. In the example it gives qu = 372.4 kPa against 520.0 kPa for the square. The allowable load is per metre of length.
Square / CircularB/L = 1: Fcs = 1.65, Fqs = 1.62, Fγs = 0.6000 in the example. The area for the allowable load is B² or πB²/4.
RectangularB/L between 0 and 1. With L = 2.4 m the example gives 446.2 kPa, between the strip and the square.
Water table: None or deeper than BNo water effect: q = γ Df and γ in the self-weight term.
Water table: within B below the baseThe self-weight term takes a weighted unit weight between γ and the submerged weight.
Water table above the baseThe overburden is split into a moist and a submerged part and the self-weight term uses the submerged weight γ′ = γsat − 9.81.
Load inclination βReduces every term; the self-weight term is zero once β ≥ φ. The equation gives the vertical component; the resultant is that divided by cos β.

Which should I pick?

  • The shape that matches the plan: a wall footing is a strip; a column footing is square or rectangular; a tank or a silo base is circular. For a rectangle enter the shorter side as B.
  • The water table that governs the design, which may be the highest level during the life of the structure. The module reads the depth from the ground surface.
  • β = 0 for a vertical load. For an inclined load give the angle of the resultant, and enter qapplied as V/A of the vertical component.

Analyze and read the results

Press Analyze. The bar changes to Analysed — bearing capacity calculated; applied pressure not provided (or Analysed — PASS / FAIL when you entered qapplied) and says “The inputs are locked. Edit inputs clears the results; the unit system can still be changed.” The page stays on the Model tab: open the Results tab for the answer. Before you press Analyze the bar reads “Not analysed”; the drawing follows the inputs.

The Results tab of the example: the four cards 520.0, 507.1, 173.3 and 169.0 kPa, the allowable loads, the overburden and FS, the Design check showing NOT CHECKED, and the start of the table Factors and values, step by step.
The Results tab of the example.
CardThe example
Gross ultimate bearing capacity qu520.0 kPa
Net ultimate bearing capacity qu,net = qu − q507.1 kPa
Gross allowable qall,g = qu / FS173.3 kPa
Net allowable qall,n = (qu − q) / FS169.0 kPa
Gross allowable vertical load Qall249.6 kN
Allowable resultant load at β = 10°, Qall(incl)253.4 kN
Overburden at the base q12.85 kPa

Below the cards, the Design check box compares the applied pressure with the allowable one, and Factors and values, step by step lists every factor with its value and the answer of each step. A last table, Contribution of each term, gives the cohesion, surcharge and self-weight terms in kPa and as a share of qu; in the example the surcharge term is 470.17 kPa (90.4 %), the self-weight term 49.82 kPa (9.6 %) and the cohesion term zero. With qapplied entered, the Capacity view adds lines “qapplied … FSactual … — PASS/FAIL” under the gross and the net pressures. Gross and net are never mixed: the gross applied pressure is compared with the gross allowable one and the net applied pressure with the net allowable one.

The design check

The check compares qapplied with qall,g and its net part qapplied − q with qall,n, and gives the actual factor of safety FSactual = qu / qapplied. Without qapplied the box reads NOT CHECKED and the bar says “applied pressure not provided”: the capacity is given and the check waits for the pressure.

With qapplied = 150 kPa the example reads PASS (173.3 kPa allowable, FSactual = 3.47); with 200 kPa it reads FAIL (FSactual = 2.60 against FS = 3.00, both the gross and the net line FAIL).

The Results tab with an applied pressure of 200 kPa: the Design check FAIL with the gross line 200.00 kPa above 173.33 kPa and the net line 187.16 kPa above 169.05 kPa.
The design check with 200 kPa: FAIL.
The bar after Analyze with an applied pressure of 150 kPa: Analysed, PASS.
The bar with PASS.
The bar after Analyze with an applied pressure of 200 kPa: Analysed, FAIL.
The bar with FAIL.

Using the numbers

  • qu is the pressure at which the ground fails. The allowable pressures divide it by FS; which of the two (gross or net) your design follows is for you to state.
  • The allowable vertical load is qall,g times the base area (B × L, πB²/4 for a circle) and, for a strip, per unit length (kN/m, tf/m or kip/ft). With an inclined load the second line is Qall / cos β.
  • The pressures are in kPa, t/m² or ksf by the unit system. The example gives 53.02 t/m² and 10.86 ksf for qu.
  • After you change the unit system the drawings stay in SI (the view says so) and the boxes show the converted values unrounded. Changing it after Analyze re-states the cards without a new run. Edit inputs unlocks the inputs and clears the results.

Warnings and notes

The bar carries a Warnings (0) button after Analyze. It opens a window that reads “No warnings — the method’s assumptions hold for these inputs.” A condition that stops the analysis is shown before the analysis, see Messages. The one caution is a load inclination larger than φ.

The Calculations tab, the report and the Theory tab

The Calculations tab opens with Given and what is sought and then writes out the working in nine numbered steps with your numbers:

  1. Compute the bearing-capacity factors — Nq, Nc and Nγ with their formulas.
  2. Apply shape factors — B/L and Fcs, Fqs, Fγs.
  3. Apply depth factors — Df/B, the form used (linear, or with arctan above 1) and Fcd, Fqd, Fγd. When Df/B lies between 0.6 and 1.6 the step notes that the two forms meet at 1 with a step, so qu changes by a few per cent as Df/B crosses 1.
  4. Apply inclination factors — Fci, Fqi, Fγi.
  5. Locate the groundwater table — the case, q and the unit weight of the self-weight term.
  6. Write the general bearing-capacity equation — the equation with your numbers, the three terms and qu, then the share of each term.
  7. Apply the factor of safety — qu,net, qall,g and qall,n.
  8. Compute the gross allowable load — Qall, and Qall(incl) when β is above 0.
  9. Check the applied foundation pressure — the PASS or FAIL lines, or the note that no pressure was entered.

A last box, Answer, gives the result in a sentence.

The Calculations tab: the three factors Nq 23.18, Nc 35.49 and Ngamma 30.21 of step 1, and the start of step 2 with the shape formulas.
The Calculations tab: step 1 results and the start of step 2.

The report

In the Report tab fill in the cover (project, location, client, report number, date, prepared by, title or qualification, checked by, and optional notes). The details are kept in this browser and saved with the model file. Save as PDF and Download Word (.docx) produce the summary report; the preview below the buttons is the report itself, and it is built after you press Analyze.

The report has six parts: 1 Introduction and scope, 2 Input data (a table and the section drawing), 3 Calculation (the steps above), 4 Results (with the drawing of the terms and the pressures), 5 Summary and 6 References. When the analysis carries a caution, a part Warnings and notes comes before the Summary and the report has seven parts. It states the units used.

The Report tab: the cover form with project, location, client, report number, date, prepared by, title and checked by, the notes box, the buttons Save as PDF and Download Word, and the top of the report.
The Report tab: the cover details, the two buttons and the first page.

The Theory tab

The Theory tab has fifteen sections: The general equation, Meyerhof’s slip-line field, Stresses on the equivalent free surface, The radial zone and the wedge, The angle θ and the surface footing, The self-weight term, The bearing-capacity factors, Shape factors, Depth factors, Inclination factors, The complete equation, The water table, Allowable pressure and the check, Worked example and References. Each opens when you click its title.

Worked example: the module’s own example

The module opens on this example, so you can follow the numbers on your own screen.

Inputs of the example
SectionInputValue
FootingShape, B, DfSquare, B = 1.2 m, Df = 1 m
Soilc, φ, γ0 kPa, 32°, 16 kN/m³
GroundwaterPresent, γsat, Dw19.5 kN/m³, 0.5 m
Loadsβ, qapplied10°, empty
Analysis SettingsFS3

Step 1: the factors

tan 32° = 0.6249. Nq = exp(π × 0.6249) × tan²(61°) = 23.18, Nc = (23.18 − 1) / 0.6249 = 35.49, Nγ = 2 × (23.18 + 1) × 0.6249 = 30.21.

Step 2: shape, depth and inclination

A square: B/L = 1, so Fcs = 1 + 23.18 / 35.49 = 1.65, Fqs = 1 + 0.6249 = 1.62, Fγs = 1 − 0.4 = 0.6000. Df/B = 0.8333, so Fqd = 1 + 2 × 0.6249 × (1 − 0.5299)² × 0.8333 = 1.23, Fcd = 1.2301 − (1 − 1.2301) / (35.49 × 0.6249) = 1.24 and Fγd = 1. For β = 10°: Fci = Fqi = (1 − 10/90)² = 0.7901 and Fγi = (1 − 10/32)² = 0.4727.

Step 3: the water

The water table (0.5 m) is above the base (1 m). γ′ = 19.5 − 9.81 = 9.69 kN/m³, q = 0.5 × 16 + 0.5 × 9.69 = 12.85 kPa, and the self-weight term uses γ′ = 9.69 kN/m³.

Step 4: the capacity

qu = 0 + 12.845 × 1.625 × 1.2301 × 0.7901 × 23.18 + ½ × 9.69 × 1.2 × 0.6 × 1 × 0.4727 × 30.21 = 470.17 + 49.82 = 520.0 kPa

qu,net = 520.0 − 12.85 = 507.1 kPa; qall,g = 520.0 / 3 = 173.3 kPa; qall,n = 507.1 / 3 = 169.0 kPa; Qall = 173.3 × 1.2 × 1.2 = 249.6 kN; and Qall(incl) = 249.6 / cos 10° = 253.4 kN. These are the cards of the Results tab.

Other unit systems

The default example in SI · tf gives qu = 53.02 t/m² and in US 10.86 ksf: the same pressure in other units. Two checks by hand, calculated outside the module:

  • US. A square footing B = 4 ft at Df = 3 ft, c = 0, φ = 30°, γ = 110 pcf, no water table, vertical load. Nq = 18.40, Nc = 30.14, Nγ = 22.40; q = 3 × 110 = 330 psf; Fqs = 1.577, Fγs = 0.6, Fqd = 1.217. qu = 0.330 × 1.577 × 1.217 × 18.40 + ½ × 0.110 × 4 × 0.6 × 22.40 = 11.65 + 2.96 = 14.6 ksf. The module gives 14.61 ksf, qall,g = 4.870 ksf and Qall = 77.92 kip.
  • SI · tf. A strip B = 1.5 m at Df = 1 m, c = 0.1 kg/cm², φ = 28°, γ = 1.8 t/m³, no water table, vertical load: Nq = 14.72, Nc = 25.80, Nγ = 16.72, no shape factors, q = 1.8 t/m². The module gives qu = 85.68 t/m², qall,g = 28.56 t/m² and Qall = 42.84 tf/m; the same case in SI · kN is 840.2 kPa.
  • SI · kN. The default example above, 519.99 kPa, was reproduced independently from the formulas to the second decimal; so were the strip, the rectangle and every row of the table below.

How each input changes the answer

Each row changes one thing in the example (a 1.2 m square footing, Df = 1 m, c = 0, φ = 32°, γ = 16 kN/m³, γsat = 19.5 kN/m³, the water table at 0.5 m, β = 10°, FS = 3) and runs the module again; the clay rows change the soil and the water as stated. The numbers are the ones the module gives, so you can reproduce any row. Pressures are in kPa; qall,g is qu divided by FS.

The example with one change at a time
Changequqall,g
The example: square 1.2 m, Df = 1 m, c = 0, φ = 32°, γ = 16, γsat = 19.5, Dw = 0.5 m, β = 10°, FS = 3
The reference
520.0173.3
Strip
No shape correction: the lowest of the shapes
372.4124.1
Rectangle, L = 1.8 m
Between the strip and the square
470.8156.9
Rectangle, L = 2.4 m
Halfway between the strip and the square (B/L = 0.5)
446.2148.7
Circular, B = 1.2 m
The same as the square
520.0173.3
Df = 0 (on the surface)
No surcharge: q = 0
63.3421.11
Df = 0.5 m
Water table at the base level
315.3105.1
Df = 1.2 m
Df/B = 1
611.2203.7
Df = 2 m
The deep form of the depth factors (Df/B above 1)
911.2303.7
Df = 3 m
Capacity rises strongly with depth
1,324441.3
B = 0.6 m
Within 1 % of the example: the surcharge term falls with B through the depth factors and the self-weight term rises
515.9172.0
B = 2 m
Within 1 % of B = 1.2 m
518.0172.7
φ = 25°
Much lower: qu is very sensitive to φ
213.471.15
φ = 38°
More than doubles qu
1,203400.9
φ = 45°
Very high; check that φ is a design value
3,7031,234
c = 5 kPa
The cohesion term appears
807.5269.2
c = 20 kPa
The cohesion term is large
1,670556.7
γ = 18 kN/m³
Raises the surcharge above the water table
556.6185.5
γsat = 21 kN/m³
Raises the submerged weight
555.2185.1
Water table: None
No submerged weight: higher
667.9222.6
Dw = 0 (at the surface)
Everything submerged: lower
404.5134.8
Dw = 1 m (at the base)
Surcharge dry, self-weight submerged
635.5211.8
Dw = 1.6 m (0.6 m below the base)
Within one width below the base: a weighted unit weight
651.7217.2
Dw = 3 m
Deeper than B below the base: the same as no water
667.9222.6
β = 0 (vertical load)
The highest: no inclination factor
700.5233.5
β = 20°
Strong reduction
374.8124.9
β = 32° (= φ)
Fγi = 0: the self-weight term drops out
247.182.38
β = 40° (above φ)
A caution appears; Fγi is still 0
183.761.22
Clay: φ = 0, c = 50 kPa, no water, β = 10°
Nc = 5.14, Nq = 1, Nγ = 0
336.1112.0
The same clay, vertical load
No inclination
425.3141.8

The pattern follows the equation. The friction angle, the load inclination and the founding depth change qu strongly; depth raises it through q and the depth factors; the shape factors lower it from the square to the strip; and the water table lowers it by cutting the unit weights. For B between 0.6 and 2 m the result changes by under 1 %, because the growing self-weight term is nearly offset by the falling depth factors; wider footings gain again (B = 5 m gives 610.9 kPa). The factor of safety does not change qu; it divides it: FS = 2 gives qall,g = 260.0 kPa and FS = 2.5 gives 208.0 kPa.

Messages: when the module stops, and what it notes

The module checks the inputs as you type and again when you press Analyze. There are three kinds of message.

A condition of the method is not met (before Analyze)

While you type, the bar turns brown and reads Cannot be analysed — with the condition; Analyze is disabled and the boxes keep their colour. Nothing is calculated.

The bar with a rectangular footing whose length is shorter than its width: Cannot be analysed, L = 0.8000 m is shorter than B = 1.20 m, with the explanation and the advice, and the Analyze button disabled.
The bar when L is shorter than B.
WhenMessage and what to do
A rectangle with L shorter than B“L = 0.8000 m is shorter than B = 1.20 m.” De Beer’s shape factors are defined with B as the shorter side and L ≥ B the longer one. Swap the two values, or enter the longer side as L.
γsat is not above the unit weight of water, with the water table present“γsat ≤ γw — the submerged unit weight would not be positive.” A negative effective weight is not physical. Check γsat.
qu does not exceed the overburden qFor example φ = 0 and c = 0 in the example: “qu = 10.15 kPa does not exceed the overburden q = 12.85 kPa at the base level.” The soil would fail under less than the pressure that already acts at the base. Check the loads and the inputs. The same stop appears for β = 89° in the example.

An input is empty or outside its range (when you press Analyze)

A window titled Cannot analyse — 1 input error (or 2 input errors …) lists each message; the limits are shown in the units of the unit system chosen.

The window Cannot analyse, 1 input error: Footing width (short side) (B) is missing.
The window when the width is empty.
WhenMessage
A required box is empty“Footing width (short side) (B) is missing.”
A value is below its limit“Footing width (short side) (B) must be at least 0.05 m.” (in US, “… at least 0.16405 ft.”), “Founding depth (Df) must be at least 0 m.”, “Cohesion (c) must be at least 0 kPa.”, “Factor of safety (FS) must be at least 1.”, “Applied vertical gross pressure at the base (optional) (qapplied) must be at least 0 kPa.”
A value is above its limit“Friction angle (φ) must be at most 50°.”, “Load inclination from vertical (β) must be at most 89°.”
Several are wrongThe window lists them together, for example “3 input errors”.

A caution after Analyze

When β is larger than φ the analysis runs and a Warnings (1) window opens: “β = 40.00° exceeds φ = 32.00°. Fγi assumes β ≤ φ; beyond that it is taken as 0, so the self-weight term drops out. Check the load inclination, or read this as a rough bound.” The Results tab then carries the badge CHECK THE WARNINGS and the bar a warning count. With usual values the Warnings window reads “No warnings — the method’s assumptions hold for these inputs.”

The Warnings window: β = 40.00° exceeds φ = 32.00°, with the explanation and the advice, and the Close button.
The caution for β above φ.

Good practice and common mistakes

  • Enter qapplied as V/A of the vertical component. It includes the weight of the footing and of the soil above it. Entering the resultant Q/A with an inclined load makes the check too severe.
  • Mind gross and net. The module gives both; state which convention your design follows. The gross check is the stricter of the two.
  • Use the water table that governs. The module reads Dw from the ground surface, not from the base.
  • Put the shorter side in B. A rectangle with L shorter than B is refused.
  • Use design values of φ and c. qu rises steeply with φ: 25° gives 213.4 kPa and 38° gives 1,203 kPa in the example.
  • One soil only. The module takes one soil under the footing; if the ground changes within about one width below the base, run it with the weaker soil for a conservative value.
  • Read the unit boxes. After you switch the system, type values in the units shown beside the boxes.
  • Keep a record. The report is the record of an analysis; use Quick Save… or Save to file… to keep the model.

Frequently asked questions

Which equation does the module use?

Meyerhof’s general bearing capacity equation: qu = c Fcs Fcd Fci Nc + q Fqs Fqd Fqi Nq + ½ γ B Fγs Fγd Fγi Nγ, with De Beer’s shape factors, Hansen’s depth factors and Meyerhof’s inclination factors. For the example it gives 520.0 kPa.

Which footing shapes can I analyse?

Strip, square, rectangular and circular, at any ratio Df/B. A circle is treated like a square of side B (the diameter), and a strip has no shape correction.

Does it handle an inclined load?

Yes, through β from 0 to 89° and the inclination factors. The equation returns the vertical component of the ultimate load; the module also gives the allowable resultant load Qall / cos β. When β is larger than φ the self-weight term is taken as zero and a caution is shown.

What is the difference between the gross and the net values?

The gross values are total pressures at the base. The net values take away the overburden q that already acts at the base level. qall,g = qu / FS and qall,n = (qu − q) / FS. A gross applied pressure is compared with the gross value and a net one with the net value.

What do I enter as the applied pressure?

The vertical gross pressure at the base, V/A: the vertical load of the column plus the weight of the footing and of the soil above it, over the base area, with service loads. With an inclined load use the vertical component. It is optional; without it the module gives the capacity and the Design check reads NOT CHECKED.

How is the water table handled?

Choose Present or None. With a water table, give its depth from the ground surface and the saturated unit weight. Above the base it splits the overburden and makes the self-weight term submerged; up to one width below the base it gives the self-weight term a weighted unit weight; deeper than that it has no effect.

Why does the width change the capacity so little?

In this example, for widths up to about 2 m, two effects offset each other: a wider footing has a larger self-weight term, but its ratio Df/B is smaller, so the depth factors and the surcharge term are lower. In the example B = 0.6, 1.2 and 2 m give 515.9, 520.0 and 518.0 kPa.

What values does the module accept?

B and L at least 0.05 m, Df and Dw at least 0, c at least 0, φ from 0 to 50°, β from 0 to 89°, the unit weights at least 0.1, FS at least 1, and every box filled except the applied pressure. Anything else stops the analysis with a message that names the value.

Which units does it use?

SI · kN, SI · tf or US, switchable in the header at any time, even after Analyze. The pressure is in kPa, t/m² or ksf, the load in kN, tf or kip (per metre or per foot for a strip) and lengths in m or ft. The default example gives 520.0 kPa, 53.02 t/m² or 10.86 ksf.

What does the report contain?

A cover with your project details and the answer, then six parts (seven when the analysis carries a caution, with Warnings and notes before the summary): introduction and scope, input data with the section drawing, the calculation step by step, results with the drawing of the terms and pressures, summary and references. It is saved as a PDF or a Word file.

Does the module remember my inputs?

Yes. Every change is kept in the browser, and the page opens again on the model you last worked on, including its analysed state. Reset to defaults brings back the example; Save to file and Quick Save keep copies.

Can I drag things on the drawing?

No. The drawings follow the numbers; the Show chips only switch the mechanism and the dimensions on and off in the Section view.