Which surcharge module do I need?
The Surcharge Loads family has seven modules. All of them answer the same question: how much extra lateral pressure does a wall take from a load on the ground behind it? Pick the one whose load looks like yours.
| The load behind your wall | Module |
|---|---|
| One to three concentrated loads, such as a wheel, a column or a crane outrigger | Point load |
| A uniform load on a strip parallel to the wall, such as a footing, a rail line or a road lane | Strip load |
| A line load parallel to the wall, such as a wall footing or a kerb | Line load |
| A load that rises to a peak and falls again across a strip, as under a stockpile | Triangular load |
| A uniform surcharge over the whole surface behind the wall | Uniform load |
| Several rectangular loaded areas anywhere in plan, with the pressure, shear and moment on the wall at a chosen section | Area loads |
| A load that rises from zero to a plateau that runs on, as behind a ramp or an embankment slope | Ramp load |
The seven manuals
Each manual follows the same plan: what the module calculates, what you need before you start, a quick start, the screen and its views, every input, the results, the report, a worked example you can reproduce, a table of how each input changes the answer, the messages the module gives, and answers to common questions.
The solutions side by side
| Module | Load | Solution |
|---|---|---|
| Point load | One to three point loads on one line | Boussinesq, for a rigid wall |
| Strip load | Strip parallel to the wall | Elastic strip solution |
| Line load | Line parallel to the wall | Boussinesq, NAVFAC form |
| Triangular load | Load rising linearly across a strip | Elastic solution |
| Uniform load | Uniform over the whole surface | K·q, constant with depth |
| Area loads | Rectangles in plan | Boussinesq integration |
| Ramp load | Rise to a plateau | Elastic solution |
A typical surcharge check in order
- Describe the wall and the ground
Open the module that matches the load and enter the wall height and the load, with the distances measured as the module asks.
- Analyze and read the diagram
Press Analyze. Read the pressure with depth, the resultant and its height, and look at the plan and 3D views to see that the load sits where you meant it.
- Move the load
Where the load has a position, drag it on the drawing to see how the position changes the pressure and the resultant, then type the values you settle on.
- Combine and report
Add the resultant of each load to the earth pressure on the wall, save a report from each run, and fill in the cover so that the project and the checker are named on it.
Frequently asked questions
How do I calculate the lateral pressure on a wall from a surcharge with GeoTerva?
Open the module that matches the load, enter the wall height and the load, press Analyze, and read the pressure with depth, the resultant and the height at which it acts.
Which module do I use for a uniform surcharge over the whole surface?
Use Uniform load. It gives a constant pressure K·q with its resultant at mid-height.
Which module do I use for a strip footing or a road lane beside the wall?
Use Strip load: a uniform load on a strip between two distances from the wall.
Can I analyse several loads of different kinds together?
Each module takes one kind of load. Run the modules one after the other and add the resultants.
Can I move a load on the drawing?
Yes, for the loads that have a position. Drag the load on the drawing; the diagram and the numbers follow. The Uniform load covers the whole surface, so it has nothing to drag.
Which views does a surcharge module draw?
Elevation, plan and 3D, with the load and the pressure diagram in each.