Surcharge loads: the user manuals

Seven modules give the extra lateral pressure a wall takes from loads on the ground behind it. This page helps you choose the module that matches your load and links to the manual of each.

Updated 17 October 2026 · GeoTerva user manual

Which surcharge module do I need?

The Surcharge Loads family has seven modules. All of them answer the same question: how much extra lateral pressure does a wall take from a load on the ground behind it? Pick the one whose load looks like yours.

The load behind your wallModule
One to three concentrated loads, such as a wheel, a column or a crane outriggerPoint load
A uniform load on a strip parallel to the wall, such as a footing, a rail line or a road laneStrip load
A line load parallel to the wall, such as a wall footing or a kerbLine load
A load that rises to a peak and falls again across a strip, as under a stockpileTriangular load
A uniform surcharge over the whole surface behind the wallUniform load
Several rectangular loaded areas anywhere in plan, with the pressure, shear and moment on the wall at a chosen sectionArea loads
A load that rises from zero to a plateau that runs on, as behind a ramp or an embankment slopeRamp load

The seven manuals

Each manual follows the same plan: what the module calculates, what you need before you start, a quick start, the screen and its views, every input, the results, the report, a worked example you can reproduce, a table of how each input changes the answer, the messages the module gives, and answers to common questions.

What the seven modules share

  • The workspace. The drawing, the tabs, Analyze and the input lock, units and the report follow the same layout as the other GeoTerva modules. See the workspace guide.
  • Three views. Every module draws the load and the pressure diagram in elevation, in plan and in 3D.
  • Loads moved on the drawing. In the modules that place a load at a distance from the wall, you can drag the load on the drawing to move it; the diagram and the numbers follow. The Uniform load covers the whole surface, so there is nothing to drag.
  • The answer. The lateral pressure with depth, the resultant and the height at which it acts, for design of the wall.

The solutions side by side

ModuleLoadSolution
Point loadOne to three point loads on one lineBoussinesq, for a rigid wall
Strip loadStrip parallel to the wallElastic strip solution
Line loadLine parallel to the wallBoussinesq, NAVFAC form
Triangular loadLoad rising linearly across a stripElastic solution
Uniform loadUniform over the whole surfaceK·q, constant with depth
Area loadsRectangles in planBoussinesq integration
Ramp loadRise to a plateauElastic solution

A typical surcharge check in order

  1. Describe the wall and the ground

    Open the module that matches the load and enter the wall height and the load, with the distances measured as the module asks.

  2. Analyze and read the diagram

    Press Analyze. Read the pressure with depth, the resultant and its height, and look at the plan and 3D views to see that the load sits where you meant it.

  3. Move the load

    Where the load has a position, drag it on the drawing to see how the position changes the pressure and the resultant, then type the values you settle on.

  4. Combine and report

    Add the resultant of each load to the earth pressure on the wall, save a report from each run, and fill in the cover so that the project and the checker are named on it.

Frequently asked questions

How do I calculate the lateral pressure on a wall from a surcharge with GeoTerva?

Open the module that matches the load, enter the wall height and the load, press Analyze, and read the pressure with depth, the resultant and the height at which it acts.

Which module do I use for a uniform surcharge over the whole surface?

Use Uniform load. It gives a constant pressure K·q with its resultant at mid-height.

Which module do I use for a strip footing or a road lane beside the wall?

Use Strip load: a uniform load on a strip between two distances from the wall.

Can I analyse several loads of different kinds together?

Each module takes one kind of load. Run the modules one after the other and add the resultants.

Can I move a load on the drawing?

Yes, for the loads that have a position. Drag the load on the drawing; the diagram and the numbers follow. The Uniform load covers the whole surface, so it has nothing to drag.

Which views does a surcharge module draw?

Elevation, plan and 3D, with the load and the pressure diagram in each.