What the module calculates
Triangular load gives the extra horizontal pressure that a long surface load of triangular shape puts on a vertical wall, with the resultant force PH of that pressure and the depth zR at which the resultant acts. The load lies on the ground behind the wall and runs parallel to it: its intensity is zero at the distance x from the wall, rises in a straight line to the peak q over a width c, and falls in a straight line back to zero over a width b.
The pressure at a depth z below the ground is the sum of the elastic line-load stresses (Flamant) of all the slices of the load, integrated exactly. The module then integrates the pressure over the height of the wall:
w(s) is the intensity of the load at the distance s from the wall. ψ is 2 for a rigid wall that does not yield and 1 for the half-space, as if the wall were absent: you choose between them in the Method section. All results are per unit length of wall.
What you can describe
- A wall height H and one triangular load by three distances, x, c and b, and its peak q.
- Two methods: Elastic · rigid wall (the default) and Elastic · half-space.
- Any of the three unit systems, SI · kN, SI · tf and US.
The elastic solution contains no soil property, so the module asks for none: no unit weight, no friction angle, no stiffness.
What belongs to other modules
- This module treats one triangular load. For other shapes of load behind a wall use the other modules of the family: the Point load, the Line load, the Strip load (a uniform load on a strip), the Ramp load, the Uniform load and the Area loads.
- The result is the pressure of the surcharge alone. It is one component to be combined with the other lateral actions of your retaining-system analysis, which this module does not calculate.
- The load is long and parallel to the wall, so the pressure is the same along the whole wall and the answer is a force per metre of wall, kN/m in the default unit system.
Before you start: what you need
Have these ready from your site plan and your design:
| What | Where it comes from | Notes |
|---|---|---|
| The wall height H | Your design | The height of the wall over which the pressure is added up. PH counts the pressure from the ground surface down to H and no deeper. |
| The position of the load: x, c, b | Site plan, loading drawing | x is the distance from the wall to the foot of the rising branch, c the width of the rising branch up to the peak, b the width of the falling branch. The drawings measure x from the face of the wall that the soil bears on. |
| The peak intensity q | Loading data | The intensity at the peak of the triangle, in kPa (t/m² or ksf in the other unit systems). The intensity is zero at the two feet of the triangle. |
| How the wall behaves | Your design | A wall that does not yield takes the rigid-wall method; a wall that deflects enough for the soil at its face to move takes the half-space method. |
Quick start in eight steps
- Open the module and choose the units
Open Triangular load from the Surcharge Loads family. Pick SI · kN, SI · tf or US in the header; you can change it at any time, even after Analyze.
- Enter the wall and the position of the load
In Geometry, enter the wall height H, the distance x to the load start, the rising width c and the falling width b. The drawing follows every value as you type.
- Enter the peak intensity
In Triangular load, enter the peak surcharge intensity q.
- Choose the method
In Method, pick Elastic · rigid wall (twice the elastic stress, the default) or Elastic · half-space (the elastic stress as it is).
- Adjust the load on the drawing if you like
Before you analyse, drag the load to move it, its peak to change c or its far end to change b. The boxes in the Model tab follow.
- Press Analyze
Press Analyze. The inputs lock, the pressure diagram and the resultant appear on the drawings, and the Results, Calculations and Report tabs fill in.
- Read the results
The Results tab gives the resultant force PH, its depth zR, the peak wall pressure and its depth. The Show chips above the drawing switch the pressure diagram, the resultant and the dimensions on and off.
- Check the working and make the report
The Calculations tab writes out every step with its numbers. The Report tab turns them into a summary report you can save as a PDF or a Word file.
The screen: three views and the drag handles
The layout is the one every GeoTerva module shares, described in the workspace guide. The drawing on the left has three views, chosen with the buttons above it:
- Elevation is a section through the wall and the ground: the wall, the triangle of the load with its peak value q, the dimensions x, c, b, x + c and x + c + b, and the wall height H.
- Plan looks down on the ground: the wall on the left and the load as a band parallel to it, shaded by the intensity from 0 to q and back to 0.
- 3D View shows the wall, the load and the pressure in three dimensions.




Show chips
Three chips above the drawing choose what it shows. Pressure distribution draws the pressure diagram on the wall, with the radii and angles of the Elevation view. Resultant draws the resultant force and its depth in the Elevation and 3D views. Dimensions draws the distances, widths and heights. Until you analyse, the first two are not available: the note beside the chips says “The pressure and the resultant appear after Analyze”. Dimensions works at any time.
Dragging the load
Before you analyse, the load can be moved on the drawing in any of the three views. The line under the drawing says: “Drag the load to move it, its peak to change c, or its far end to change b”.
| Handle | What it changes |
|---|---|
| The body of the load, or the marker at its start (the one nearest the wall) | x, the distance to the load start. The whole load moves; c and b stay. x cannot go below zero. |
| The peak (Elevation: the round marker at the top of the triangle; Plan: the solid line; 3D: the round marker on the peak line of the strip) | c, the rising width. x and b stay. The width keeps a minimum of 0.05. |
| The far end (Elevation: the round marker at the right foot; Plan: the dashed line; 3D: the round marker on the far edge of the strip, the one farthest from the wall) | b, the falling width. x and c stay. |
The values snap in steps of 0.05 in the unit shown, the widths keep a minimum of 0.05, and the load stops at the right edge of the drawing. The boxes of the Model tab show the new values as you drag. After Analyze the handles are plain dots and the inputs are locked; Edit inputs unlocks them again and clears the results.
Entering the model, section by section
The Model tab has three sections: Geometry, Triangular load and Method. Each opens when you click its title; Next and Back at the foot walk you through them. The tables list every field with its symbol, the unit and its default. Where a unit is shown twice or three times, such as m · ft, the units are those of SI · kN, SI · tf and US in turn, and equal ones are merged. Defaults are shown in SI; in another unit system the boxes show the converted values.
Geometry
The wall and the position of the load along the ground behind it. The four distances are also what the drag handles change.

| Field, unit and default | What to enter |
|---|---|
| Wall height Hm · ft · default 25.00 | The height of the wall; the pressure is added up from the ground surface to this depth. It must be greater than zero. |
| Distance to load start xm · ft · default 3.00 | The distance from the wall to the foot of the rising branch. Zero is allowed: the load then starts at the wall. |
| Rising branch width cm · ft · default 4.00 | The width over which the intensity rises from 0 to q. It must be greater than zero. The peak lies at x + c from the wall. |
| Falling branch width bm · ft · default 10.00 | The width over which the intensity falls from q back to 0. It must be greater than zero. The load ends at x + c + b. |
Triangular load
One number: the intensity at the peak of the triangle. It may be zero or more; with zero the pressure is zero.

| Field, unit and default | What to enter |
|---|---|
| Peak surcharge intensity qkPa · t/m² · ksf · default 20.00 | The intensity at the peak, at the distance x + c from the wall. The intensity is zero at the start and at the far end of the load. The pressure on the wall is in direct proportion to q. |
Method
Two buttons choose how the wall is treated. A (?) beside each one opens a window with a drawing, the formula and, for your current inputs, the resultant of both methods.
Under the buttons the module says what the selected method does: “Twice the elastic stress (ψ = 2), for a wall that does not yield.” for the rigid wall, and “The elastic stress in a half-space (ψ = 1), as if the wall were absent — for a wall that deflects.” for the half-space.

| Choice | Options | Default |
|---|---|---|
| Calculation method | Elastic · rigid wall Elastic · half-space | Elastic · rigid wall |

The Analyze bar
Under the three sections a bar shows the state of the model. It reads Not analysed with the line “Enter the wall, the triangular load and the method, then press Analyze. The drawings follow the inputs.” until you press Analyze. After a run it reads “Analysed — the lateral pressure calculated” and says that the inputs are locked, that Edit inputs clears the results and that the unit system can still be changed.

Choosing the method
Both methods use the same elastic stress of the triangular load. They differ in one factor, ψ, that says how the wall treats it:
| Method | ψ | What it assumes | Result |
|---|---|---|---|
| Elastic · rigid wall (default) | 2 | A wall that does not yield. It keeps the soil at its face from moving horizontally, which a mirror-image load on the other side of the face reproduces, so the elastic stress is doubled. | The larger pressure and force. |
| Elastic · half-space | 1 | A wall that deflects enough for the soil at its face to move, so that nothing holds it back: the stress is taken as it is in the half-space, as if the wall were absent. | Half the rigid-wall pressure at every depth. The resultant acts at the same depth. |
Which should I pick?
- Match the method to the wall. A wall that is held and does not yield takes the rigid-wall method. A wall that deflects enough for the soil at its face to move takes the half-space method.
- If you are not sure, run both. The (?) windows show both resultants for your inputs, and one run each gives the full results. On the example the rigid wall gives 78.41 kN/m and the half-space 39.21 kN/m, both at 8.82 m below the ground.
- Nothing else changes. The depth zR, the depth of the peak and the shape of the diagram are the same for both; only the size of the pressure differs.
Analyze and read the results
Press Analyze. The inputs lock, the pressure and the resultant appear on the drawings, and the Results tab shows seven cards. Before you analyse, the tab says “Press Analyze on the Model tab to calculate the lateral pressure.”

| Card | What it is | Example |
|---|---|---|
| Peak location | The distance from the wall to the peak of the load, x + c | 7.00 m |
| Total load width | The width of the whole triangle, c + b | 14.00 m |
| Resultant force | The resultant PH of the pressure over the wall height, per metre of wall | 78.41 kN/m |
| Resultant depth | The depth zR of the resultant below the ground | 8.82 m |
| Peak wall pressure | The largest horizontal pressure on the wall, σH,max | 6.63 kPa |
| Depth of peak pressure | The depth below the ground at which that peak acts | 4.14 m |
| Calculation method | The method used, with the wall type | Elastic (rigid wall) |
On the Elevation view the pressure diagram shows the pressure on the wall at every depth, with the rays R1, R2, R3 and the angles α, β drawn at the depth of the peak pressure, and a note with that depth and the two angles. The resultant is an arrow at its depth, with its value and a dimension zR from the ground. In the 3D view the same pressure stands on the wall as a curtain of curves.


Units after Analyze
The unit system can be changed after a run: the inputs and the results follow. On the example the US system gives the resultant as 5.37 kip/ft at 28.92 ft below the ground, with a peak pressure of 0.1386 ksf at 13.59 ft. In SI · tf the resultant is 8.00 tf/m and the peak pressure 0.6765 t/m².
The Calculations tab and the report
The Calculations tab writes out the working in four numbered steps:
- Load geometry — the three positions x, x + c and x + c + b, with the peak at 7.00 m and the end at 17.00 m on the example, and the method with its factor ψ.
- Radii and angles at a depth — R1, R2, R3, α and β at the depth of the peak pressure.
- Horizontal pressure — the equation with the functions A(s) and B(s), the pressure at the depth of the peak, and a table of the pressure profile at every H/30 of the wall height, with R1, R2, R3, α, β and σH in each row.
- Resultant and its depth — PH and zR, both below the ground and above the base of the wall.

The Report tab turns the same working into a summary report. Fill in the cover (project, location, client, report number, date, prepared by, title or qualification, checked by, and optional notes) and press Save as PDF or Download Word (.docx). The cover details are kept in your browser. The report has six parts: 1 Introduction and scope, 2 Input data (with the three drawings), 3 Calculation (one part for each step above), 4 Results, 5 Summary and 6 References. It is written in the unit system shown, and its units line gives the conversion constants.

The report gives the results with a little more precision than the cards: on the example PH = 78.41 kN/m, zR = 8.816 m and σH,max = 6.635 kPa.
The Theory tab explains the method in six numbered sections: Triangular load on a wall, Radii and angles, Horizontal pressure, Resultant and line of action, Worked example and References. The worked example there is fixed: it does not follow your inputs.
Worked example: the module’s own example
The module opens on this example, so you can follow the numbers on your own screen.
| Section | Input | Value |
|---|---|---|
| Geometry | Wall height, distance to load start | H = 25 m, x = 3 m |
| Geometry | Rising and falling widths | c = 4 m, b = 10 m |
| Triangular load | Peak surcharge intensity | q = 20 kPa |
| Method | Calculation method | Elastic · rigid wall, ψ = 2 |
Step 1: the load
The peak lies at x + c = 3 + 4 = 7.00 m from the wall and the load ends at 7 + 10 = 17.00 m, so its total width is c + b = 14.00 m. The load on the ground is the area of the triangle, ½ × 20 × 14 = 140 kN per metre of wall.
Step 2: the pressure at the depth of the peak
The peak pressure acts at z = 4.14 m. There the three rays have the lengths R1 = √(3² + 4.14²) = 5.11 m, R2 = √(7² + 4.14²) = 8.13 m and R3 = √(17² + 4.14²) = 17.50 m, and the angles are α = 23.471° and β = 16.917°. The module’s equation gives σH = 6.63 kPa for the rigid wall; the half-space gives half of it, 3.32 kPa.
| z (m) | α (°) | β (°) | σH (kPa) |
|---|---|---|---|
| 0.00 | 0.000 | 0.000 | 0.00 |
| 2.50 | 20.152 | 11.288 | 5.81 |
| 5.00 | 23.499 | 19.148 | 6.49 |
| 10.00 | 18.293 | 24.542 | 3.95 |
| 15.00 | 13.707 | 23.559 | 2.14 |
| 25.00 | 8.799 | 18.573 | 0.72 |
The pressure is zero at the ground surface, reaches its peak of 6.63 kPa at 4.14 m and falls to 0.72 kPa at the foot of the 25 m wall.
Step 3: the resultant
Integrating the pressure over the wall height gives the resultant PH = 78.41 kN/m. The depth where its moment balances is zR = 8.82 m below the ground, which is 16.18 m above the base of the wall.
A check by hand
A wall that went down without limit would take, from a load of 140 kN/m, the force ψ × 140 / π = 2 × 140 / π = 89.13 kN/m, whatever the distance x. A 25 m wall takes 78.41 kN/m of it, about 88 %, which is what you expect when most of the pressure acts within the upper part of the wall. Running the module with a wall height of 1000 m gives 89.12 kN/m, and with the half-space method 44.56 kN/m, which is half of it. An independent numerical integration of the line-load stresses of the triangle also reproduces 6.635 kPa at 4.14 m, 78.41 kN/m and 8.816 m.
How each input changes the answer
Each row below changes one thing in the example (two for the rows that set both widths) and runs the module again. The numbers are the results the module gives, in the units of SI · kN, so you can reproduce any row. The four columns are the resultant PH in kN/m, its depth zR in m, the peak pressure σH,max in kPa and its depth in m.
| Change | PH (kN/m) | zR (m) | σH,max (kPa) | Peak depth (m) |
|---|---|---|---|---|
| The default exampleThe reference | 78.41 | 8.82 | 6.63 | 4.14 |
| Half-space methodHalf the pressure at every depth; the same depths | 39.21 | 8.82 | 3.32 | 4.14 |
| Peak 40 kPaEverything is in proportion to q: double the pressure and force, the same depths | 156.83 | 8.82 | 13.27 | 4.14 |
| Peak 10 kPaHalf the pressure and force | 39.21 | 8.82 | 3.32 | 4.14 |
| Load starts at the wall (x = 0)The load is as close as it can be: more force, nearer the surface | 83.46 | 6.53 | 10.12 | 1.93 |
| Load starts 6 m from the wallFurther away: less force, deeper | 72.25 | 10.51 | 4.91 | 6.14 |
| Load starts 10 m from the wallFurther still | 63.33 | 12.13 | 3.65 | 8.64 |
| Rising branch 8 mA wider load, so more load: more force, deeper | 93.61 | 10.15 | 6.50 | 5.35 |
| Rising branch 2 mA narrower load: less force | 69.40 | 7.98 | 6.74 | 3.49 |
| Falling branch 5 mA shorter tail: less load and less force | 52.58 | 7.91 | 5.15 | 3.69 |
| Falling branch 20 mA longer tail: more load and more force, deeper | 122.12 | 10.04 | 8.59 | 4.80 |
| Symmetric 7 and 7The same load (140 kN/m) with its centre moved from 9 m to 10 m from the wall: a little less force, deeper | 76.44 | 9.45 | 5.87 | 4.78 |
| Narrow load 1 and 1 at 3 mA load of 20 kN/m only: a small force | 12.41 | 5.14 | 2.07 | 2.26 |
| Wall 3 m highThe depth of the peak (4.14 m) is below the base, so the largest pressure is the one at the base | 11.43 | 1.92 | 6.27 | 3.00 |
| Wall 5 m highOnly the pressure down to 5 m is added up | 24.53 | 3.03 | 6.63 | 4.14 |
| Wall 10 m highA shorter wall: less force, shallower resultant | 50.89 | 5.24 | 6.63 | 4.14 |
| Wall 15 m highLess force than the 25 m wall | 65.64 | 6.81 | 6.63 | 4.14 |
| Wall 40 m highMore force: the lower part adds a little | 84.49 | 10.41 | 6.63 | 4.14 |
| Wall 1000 m highThe limit of a very tall wall, 2 × 140 / π = 89.13 kN/m | 89.12 | 13.96 | 6.63 | 4.14 |
Three things stand out. The pressure is in direct proportion to q, and the method only scales it. Distance matters: moving the load from the wall to 10 m away takes the force from 83.46 to 63.33 kN/m and pushes its depth from 6.53 m to 12.13 m. And the wall height sets how much of the diagram is counted: the peak pressure of 6.63 kPa stays the same as long as the wall reaches the depth of the peak, 4.14 m.
Messages: when the module will not calculate
The module checks the five inputs. When a value is not usable it does not guess: it stops and tells you which one. A box left empty counts as a value that cannot be used.

| When | Message |
|---|---|
| The wall height H is zero, negative or empty | “The wall height H must be greater than zero” |
| The distance x is negative or empty | “The distance x must be zero or more” |
| The rising width c is zero, negative or empty | “The rising width c must be greater than zero” |
| The falling width b is zero, negative or empty | “The falling width b must be greater than zero” |
| The peak intensity q is negative or empty | “The peak surcharge q must be zero or more” |
Each message continues: “The triangle needs positive widths on a wall of positive height, and a load of zero or more. Correct the highlighted value in the Model tab.” When several inputs are wrong the messages are listed together in one line, separated by semicolons. The message appears in four places:
- above the Analyze bar in the Model tab;
- in the bar itself, which reads “Cannot be analysed — ” followed by the message;
- in a window titled Cannot be analysed, opened by pressing Analyze, which ends “Nothing was calculated. Change the inputs marked in red, then press Analyze again.”;
- on the drawings, which read “Not calculated”, and in the Results tab, which reads “Not calculated — see the Model tab.”
Correct the value and press Analyze again. A zero peak intensity q is accepted: the module runs and gives a force of 0.00 kN/m. A load that starts at the wall (x = 0) is accepted too.
Good practice and common mistakes
- Choose the method for the wall, not for the answer. The rigid-wall and half-space results differ by exactly a factor of 2; decide which describes your wall before you read either.
- Measure x from the wall. It is the distance to the foot of the rising branch, not to the peak. The peak is at x + c, and the Results tab shows it as the peak location.
- Remember the shape. The load rises over c, the side nearer the wall, and falls over b, the side further away. Check the drawing against your plan before you analyse.
- Give the full wall height. PH is the pressure added up down to H. A wall height that stops short of the depth of the peak cuts the diagram, as the 3 m and 5 m rows of the table show.
- Take the result per metre. The load is long and parallel to the wall, so PH is in kN/m. It does not include the ends of a load of finite length.
- Combine it with the other actions. This is the pressure of the surcharge alone; add it to the earth and water pressures and the other loads of your analysis as your standard requires.
- Check the units after you switch the system: type values in the units shown beside the boxes. The module converts the boxes for you when you switch.
Frequently asked questions
How do I calculate the lateral pressure on a wall from a triangular surcharge?
Describe the wall height H, the distance x from the wall to the start of the load, the rising width c, the falling width b and the peak intensity q, choose the rigid-wall or half-space method and press Analyze. GeoTerva’s Triangular load module adds up the elastic line-load stresses of the load exactly and gives the pressure on the wall, the resultant force PH per metre of wall and its depth zR, with every step of the working.
What is the difference between the rigid-wall and the half-space method?
They use the same elastic stress. The rigid-wall method doubles it (ψ = 2) for a wall that does not yield; the half-space method takes it as it is (ψ = 1), as if the wall were absent, for a wall that deflects. The half-space pressure is half the rigid-wall pressure at every depth, and the resultant acts at the same depth. On the module’s example the resultants are 78.41 kN/m and 39.21 kN/m.
Does the module need soil properties?
No. The elastic solution it uses contains no unit weight, friction angle or stiffness, so the only inputs are the wall height, the three distances of the load, the peak intensity and the method.
What do “Peak location” and “Total load width” mean?
The peak location is the distance from the wall to the peak of the triangle, x + c, 7.00 m on the example. The total load width is c + b, the width of the whole triangle, 14.00 m on the example.
Where is the pressure largest?
At a depth that depends on the geometry. On the example the peak is 6.63 kPa at 4.14 m below the ground; with the load starting at the wall it is 10.12 kPa at 1.93 m, and with the load starting 10 m away it is 3.65 kPa at 8.64 m. The pressure at the ground surface is zero.
Does the wall height change the pressure?
Not the pressure at a given depth, but how much of it is added up. PH is the area of the diagram from the ground surface down to H: on the example it is 50.89 kN/m for a 10 m wall, 78.41 kN/m for 25 m and 84.49 kN/m for 40 m. For a very tall wall the force approaches ψ times the load on the ground divided by π: 89.13 kN/m here, the value the 1000 m row of the table nearly reaches.
Can the load start at the wall?
Yes: x may be zero. The example with x = 0 gives PH = 83.46 kN/m at zR = 6.53 m. A negative distance is refused.
Can I move the load with the mouse?
Yes, before you analyse. Drag the load to move it, its peak to change the rising width or its far end to change the falling width, in the Elevation, Plan or 3D view; the boxes follow. After Analyze the inputs and the handles are locked until you press Edit inputs.
Are the results per metre of wall?
Yes. The load is long and parallel to the wall, so the pressure is the same along the whole wall and PH is a force per unit length: kN/m, tf/m or kip/ft.
What does the report contain?
A cover with your project details, an introduction and scope, the input data with the three drawings, the calculation step by step with the pressure profile, the results table with PH, zR and σH,max, a summary and the references. Save it as a PDF or download it as a Word file.
What does the message “Cannot be analysed” mean?
One of the five inputs cannot be used: the wall height or a width is zero or negative, the distance or the peak intensity is negative, or a box is empty. The message names the input; correct it and press Analyze again.
Can I put several loads on the same wall?
This module takes one triangular load. For a point, line, strip, ramp, uniform or rectangular loads use the other manuals of the Surcharge loads family.