Skip to the manual
GeoTerva Start free
User manual · Bearing capacity

Terzaghi bearing capacity: user manual

Calculate the bearing capacity of a shallow footing by Terzaghi’s equation: the ultimate and the allowable pressure, gross and net, with the failure mechanism drawn to scale and a PASS or FAIL check against your applied pressure. This manual walks through the screen, every input, the failure mode and the water table, the results and the report, with a worked example you can reproduce.

Updated 17 October 2026 · GeoTerva user manual

What the module calculates

Terzaghi gives the bearing capacity of a shallow footing by Terzaghi’s equation (1943): the pressure the ground can take at the base of the footing before it fails in shear, as an ultimate value and as an allowable value at the factor of safety you choose, each gross and net. It draws the failure mechanism to scale under the footing and writes out the working. The soil is one layer below the footing, with its cohesion, friction angle and unit weight; you choose the footing shape, general or local shear, and the water table.

The ultimate bearing capacity is the sum of three terms, for the cohesion, the surcharge of the soil above the base and the self-weight of the soil in the failure zone:

qu = sc c Nc + q Nq + sγ · ½ γ B Nγ

Nc, Nq and Nγ are the bearing capacity factors, which depend on the friction angle φ alone. q is the overburden at the base level, γ the unit weight in the failure zone (reduced below the water table) and B the width of the footing. The shape factors are sc = 1 and sγ = 1 for a strip, sc = 1.3 and sγ = 0.8 for a square and sc = 1.3 and sγ = 0.6 for a circular footing. The allowable pressures are:

qall,g = qu / FS, qu,net = qu − q, qall,n = (qu − q) / FS

What you can describe

  • A strip, square or circular footing: the width B (the diameter of a circle) and the founding depth Df, which must not exceed B.
  • General shear or local shear failure of the soil; local shear takes c′ = ⅔ c and φ′ = arctan(⅔ tan φ), as described below.
  • One soil below the footing: c, φ and the unit weight γ.
  • A water table at any depth, with the saturated unit weight; or none.
  • An optional applied vertical pressure qapplied at the base, which the module checks against the allowable pressures: PASS or FAIL.
  • The factor of safety FS.

The module takes a vertical load. It gives the pressure at the base; the settlement of the footing is a separate question that the stress and settlement modules answer.

Which module for which footing

Before you start: what you need

Have these ready from your design and your ground investigation:

WhatNotes
The footing: shape, B, Df
From: Your design
Width (the shorter side; the diameter of a circle) and the depth of the base below the ground surface. Df must not exceed B.
c, φ and γ of the soil
From: Boring logs and tests
One set of values for the soil below the footing, to a depth of about one width under the base. φ from 0° to 50°.
The water table
From: Groundwater readings
Its depth Dw from the ground surface and the saturated unit weight γsat; or none.
The factor of safety
From: Your design basis
At least 1. The example uses 3.
The applied pressure (optional)
From: Your structural analysis
The vertical gross pressure at the base, V/A, with service (unfactored) loads: the column load plus the weight of the footing and of the soil above it, over the base area.

Quick start in seven steps

  1. Open the module and choose the units

    Open Terzaghi from the Bearing Capacity family. Pick SI · kN, SI · tf or US in the header; you can change it at any time.

  2. Describe the footing

    In Footing choose Strip, Square or Circular and type the width B and the founding depth Df.

  3. Enter the soil

    In Soil type c, φ and γ and choose General shear or Local shear.

  4. Enter the groundwater

    In Groundwater choose Present and type γsat and the depth Dw, or choose None.

  5. Enter the load and the factor of safety

    In Loads type the applied vertical gross pressure qapplied if you want the footing checked; in Analysis Settings set FS.

  6. Press Analyze

    Press Analyze at the foot of the Model tab. The bar reads Analysed, the inputs lock and the drawing shows the Capacity view.

  7. Read the answer

    The Results tab gives the four pressures, the load the footing can carry, the check and the contribution of each term. The Calculations tab writes out the steps; the Report tab saves a PDF or a Word file.

The screen: section, capacity and factors

The layout is the one every GeoTerva module shares, described in the workspace guide. For this module the drawing has three views, chosen with the buttons above it:

  • Section is the footing in the ground, drawn to scale: the column, the base, the founding depth, the water table and the failure mechanism of the method for your friction angle, with the zones labelled. Zone I is the elastic wedge under the base, zone II the radial shear zone bounded by a log spiral and zone III the passive wedge. The Section view carries the load Q, the labels B and Df, the water table and a legend naming the zones (the base angle of the elastic wedge equals φ); after Analyze the surcharge q and the ultimate bearing capacity qu are added at the base level.
  • Capacity shows the three terms of qu as one stacked bar with their shares, then the gross pressures (qu and qall,g ) and the net pressures (qu,net and qall,n ) as bars, and the three factors. It reads “Press Analyze” until the model is analysed. When you entered an applied pressure it adds a bar for it with FSactual and PASS or FAIL.
  • Factors plots Nc, Nq and Nγ against the friction angle on a logarithmic scale from 0° to 50°, with a dashed line at your φ and the values read off. For local shear it marks the reduced angle φ′.
The Section view before Analyze: a square footing 1.50 m wide at 1.00 m depth, the water table at 2.00 m and the three zones of the failure mechanism drawn to scale, with the Show bar above.
Section before Analyze: the footing, the water table and the mechanism, to scale.
The Section view after Analyze: the same drawing with the ultimate bearing capacity 514.6 kPa at the base and arrows under the footing.
Section after Analyze: qu is added at the base.
The Capacity view after Analyze: the stacked bar of the three terms of 514.6 kPa, the gross pressures 514.6 and 171.5 kPa, the net pressures 496.8 and 165.6 kPa, and the factors Nc 17.690, Nq 7.440 and Nγ 3.640.
Capacity after Analyze.
The Factors view: Nc, Nq and Nγ against the friction angle from 0 to 50 degrees on a logarithmic scale, with a dashed line at 20 degrees and the values 17.69, 7.44 and 3.64 marked.
Factors: the three curves and your design values.

The Show chips

Above the Section view a Show bar has two chips, Failure mechanism and Dimensions, both on by default. The (?) beside Show says that the drawing is display only. With Failure mechanism off the zone labels, the wedge and spiral lines and the legend line disappear and a note says that the mechanism is hidden; with Dimensions off the labels and lines of B and Df disappear. Both chips are on again after a reload. The Capacity and Factors views have no chips.

The Show bar with the question mark and the two checked chips Failure mechanism and Dimensions.
The Show bar of the Section view.

Entering the model, section by section

The Model tab has six sections: Model data, Footing, Soil, Groundwater, Loads and Analysis Settings. Click a title to open a section: of the five after Model data only one is open at a time, so opening one closes the previous one (Model data opens and closes on its own); Next and Back at the foot walk you through them, and Analyze waits below the last one. Where a unit is shown twice or three times, such as m · ft, the units are those of SI · kN, SI · tf and US in turn, and equal ones are merged. Defaults are shown in SI; after a unit switch the boxes show the converted values, unrounded (the 1.5 m footing reads 4.92126 ft).

Model data

The first section holds the model name, Save to file…, Open file…, Quick Save… with its list, Load, Delete and Reset to defaults. It works as described in the workspace guide.

The Model data section with the model name, Save to file, Open file, Quick Save, Reset to defaults and the quick-save list with Load and Delete.
Model data.

Footing

The Footing shape buttons are Strip, Square and Circular; the example is square. A strip is a footing long compared with its width, so the module works per metre of length; the square and circular footings are sized by B. The note under the fields reminds you that B is the shorter side and Df the depth of the base below the ground surface.

The Footing section with the shape buttons Strip, Square and Circular, the width 1.5 m and the founding depth 1 m.
Footing: shape, width and depth.
Footing fields
FieldDefaultWhat to enter
Footing width / diameter B
m · ft
1.5The shorter side of the footing, or the diameter of a circle. At least 0.05 m.
Founding depth Df
m · ft
1The depth of the base below the ground surface. Zero or more, and not more than B.

Soil

One soil below the footing. Failure mode has General shear, the default, and Local shear, which the label describes as reducing c and φ. The note says that the soil is one layer below the footing, characterised by c, φ and γ.

The Soil section with cohesion 15.2 kPa, friction angle 20 degrees, unit weight 17.8 kN/m3 and the Failure mode buttons General shear and Local shear.
Soil: strength, unit weight and failure mode.
Soil fields
FieldDefaultWhat to enter
Cohesion c
kPa · kg/cm² · psf
15.2Zero or more.
Friction angle φ
°
20From 0° to 50°.
Unit weight (above GWT) γ
kN/m³ · t/m³ · pcf
17.8At least 0.1. Used for the surcharge q and, with no water table, for the self-weight term.

Groundwater

Water table has Present and None. With None the two boxes disappear and the unit weight γ is used everywhere. Three read-only cards under the boxes follow your inputs: the surcharge q at the base, the water case and the ratio Df / B.

The water case card reads above the base when Dw < Df, within B below the base when the water table lies between the base and one width below it, deeper than B below that, and none without a water table.

The Groundwater section with the Present and None buttons, the saturated unit weight 19, the water table depth 2 m, and the cards: surcharge 17.80 kPa, water case within B below the base, Df/B 0.67.
Groundwater, with the three cards.
Groundwater fields (shown with the water table present)
FieldDefaultWhat to enter
Saturated unit weight γsat
kN/m³ · t/m³ · pcf
19At least 0.1, and above the unit weight of water (9.81 kN/m³).
Water table depth Dw
m · ft
2Measured from the ground surface. Zero or more.

Loads

One optional box, Applied vertical gross pressure at the base qapplied, empty by default. Enter V/A from your structural analysis with service loads: the vertical load of the column together with the weight of the footing and of the soil above it, over the base area. A (?) beside the heading opens a window with a drawing of what the pressure contains and of the gross and the net check. Leave the box empty to get the bearing capacity without a check.

The Loads section with the empty box for the applied vertical gross pressure and its note.
Loads.
The help window of Loads: a footing with the column load V, the weight of the footing Wf and of the soil Ws, the pressure under the base, and the gross and net checks.
The (?) window of Loads.

Analysis Settings

The Factor of safety FS divides the ultimate pressures to give the allowable ones. Default 3; at least 1.

The Analysis Settings section with the factor of safety 3.
Analysis Settings.

Choosing the footing, the failure mode and the water

Four decisions shape the answer. The first three are choices on the screen; the fourth, the water table, comes from your inputs.

ChoiceWhat it does
Footing shape
Strip, Square, Circular
Sets the shape factors sc and sγ and the plan area for the load Qall. For the example: 442.1 kPa strip, 514.6 kPa square, 506.4 kPa circular.
Failure mode
General shear, Local shear
General shear uses c and φ as entered. Local shear replaces them by c′ = ⅔ c and φ′ = arctan(⅔ tan φ) and uses the same equation. The example falls to 235.8 kPa.
Water table
Present, None
Changes q and the unit weight in the self-weight term, by the case below.

General or local shear

General shear is the failure with a clear surface from the footing to the ground surface, in dense sand and stiff clay. Local shear stands for the failure of loose sand and soft clay, where the strength is not fully mobilised; the module then works with the reduced values and the Calculations tab states them. For the example φ′ = 13.64° and c′ = 10.13 kPa.

The water table

The module reads the depth Dw from the ground surface and uses one of three cases:

  • Above the base (Dw < Df): the surcharge is q = γ Dw + γ′ (Df − Dw) and the self-weight term uses the submerged unit weight γ′ = γsat − 9.81.
  • Within one width below the base (Dw ≥ Df and D = Dw − Df ≤ B): q = γ Df, and the self-weight term uses γav = [D γ + γ′ (B − D)] / B.
  • Deeper than B below the base: the water table lies below the failure zone and has no effect; q = γ Df and the term uses γ.

Without a water table the last case applies. With the example, a water table at 2 m is 1 m below the base: γav = 14.93 kN/m³ and q = 17.80 kPa.

Analyze and read the results

Press Analyze. The bar counts through four steps (bearing-capacity factors, corrections, groundwater, ultimate and allowable pressure), the inputs lock, and the bar and a message tell you the outcome: Analysed — bearing capacity calculated; applied pressure not provided, or with qapplied, Analysed — PASS: qapplied ≤ qall,g, FSactual = 3.43 or Analysed — FAIL: qapplied > qall,g, FSactual = 2.06. The answer is on the Results tab; the drawing changes to the Capacity view. The module stays on the Model tab, so press Results to see it.

The bar after Analyze reading Analysed, bearing capacity calculated, applied pressure not provided, and that the inputs are locked, with the buttons Warnings 0 and Edit inputs.
The bar after Analyze.

The Results tab has these blocks:

  • Bearing capacity: four cards, the gross ultimate bearing capacity qu, the net ultimate qu,net = qu − q, the gross allowable qall,g = qu / FS and the net allowable qall,n = (qu − q) / FS; under them the gross allowable vertical load Qall (kN, or per metre for a strip), the overburden q and FS.
  • Design check: NOT CHECKED without qapplied; with it, PASS or FAIL for the gross and for the net check.
  • Factors and values, step by step: the main number of each step of the working.
  • Contribution of each term: the three terms with their values and their share of qu.
The Results tab: the four pressure cards 514.6, 496.8, 171.5 and 165.6 kPa, the load 385.9 kN, the Design check NOT CHECKED, the step table and the contribution of each term.
The Results tab of the example, without an applied pressure.

The check against the applied pressure

Enter qapplied in Loads and the module compares it with the allowable pressures. Gross is compared with gross and net with net, never one with the other: the gross check is qapplied ≤ qall,g ; the net check is qapplied − q ≤ qall,n . Each comes with its actual factor of safety: gross FSactual = qu / qapplied, net FSactual,net} = qu,net / qapplied,net . The results say that the gross check governs: when it passes, the net check passes too. With the example, an applied pressure of 150 kPa gives PASS (gross 3.43, net 3.76) and 250 kPa gives FAIL (gross 2.06, net 2.14).

The Design check block for an applied pressure of 150 kPa: Gross PASS with 150.00 kPa not above 171.53 kPa, factor of safety 3.43, Net PASS with 132.20 kPa not above 165.60 kPa, net factor of safety 3.76.
Design check, 150 kPa: PASS.
The Design check block for an applied pressure of 250 kPa: Gross FAIL, factor of safety 2.06, Net FAIL, net factor of safety 2.14.
Design check, 250 kPa: FAIL.

The Warnings button of the bar opens the list of warnings and notes. For the inputs of this module the list reads “No warnings — the method's assumptions hold for these inputs.”

The Calculations tab, the Report and the Theory tab

The Calculations tab writes the analysis as an answer sheet, one card per step; each card opens and closes. It starts with Given and what is sought, then:

  1. Check the shallow-footing assumption: Df / B, and that Df ≤ B.
  2. Read the bearing-capacity factors: Nc, Nq and Nγ for φ, with the rows of the table around it. Local shear adds a step, Reduce the strength for local shear, before the factors.
  3. Locate the groundwater table: the case, q and the unit weight of the self-weight term.
  4. Write the bearing-capacity equation for the shape: the equation, your numbers substituted, qu and the contribution of each term.
  5. Apply the factor of safety: the net ultimate and the gross and net allowable pressures.
  6. Compute the gross allowable load Qall.
  7. Check the applied foundation pressure: the check, or a note that no pressure was entered.

It ends with a boxed Answer. All numbers follow the unit system of the header.

Part of the Calculations tab: the steps Locate the groundwater table and Write the bearing-capacity equation for a square footing, with the case, q = 17.80 kPa, gamma 14.93 kN/m3, the substituted equation and qu = 514.59 kPa.
Calculations: groundwater and the equation, with your numbers.

The Report

The Report tab has a cover form (project, location, client, report number, date, prepared by, title or qualification, checked by and optional notes), kept in the browser and printed on the cover. Save as PDF and Download Word (.docx) produce the report. It has six parts (a seventh, Warnings and notes, is added if an analysis carries a caution; this single-soil module raises none): 1. Introduction and scope, 2. Input data, 3. Calculation (a numbered step for each step above), 4. Results, 5. Summary and 6. References, with the drawings.

The Report tab: the cover form and, below it, the first page of the report with the summary table of the example.
The Report tab: cover form and the first page.

The Theory tab

The Theory tab explains the method in 14 sections: Scope and assumptions; General and local shear failure; The failure mechanism; The passive force on the wedge; The surcharge term — Nq; The cohesion term — Nc; The self-weight term — Nγ; The bearing-capacity equation; Square and circular footings; Local shear failure; The water table; Allowable pressure and the check; Worked examples; References.

Worked example

The module’s own example, which you can reproduce with Reset to defaults and Analyze: a square footing B = 1.5 m at Df = 1 m, c = 15.2 kPa, φ = 20°, γ = 17.8 kN/m³, γsat = 19 kN/m³, water table Dw = 2 m, FS = 3, general shear.

  1. Shallow footing: Df / B = 0.667 ≤ 1.
  2. Factors for 20°: Nc = 17.69, Nq = 7.440, Nγ = 3.640.
  3. Water: Dw − Df = 1 m ≤ B, so γav = (1 × 17.8 + 9.19 × 0.5) / 1.5 = 14.93 kN/m³; q = 17.8 × 1 = 17.80 kPa.
  4. Terms for a square footing: 1.3 × 15.2 × 17.69 = 349.55; 17.80 × 7.44 = 132.43; 0.4 × 14.93 × 1.5 × 3.64 = 32.61 kPa. Their sum is qu = 514.59 kPa.
  5. Safety: qu,net = 514.59 − 17.80 = 496.79 kPa; qall,g = 514.59 / 3 = 171.53 kPa; qall,n = 496.79 / 3 = 165.60 kPa.
  6. Load: Qall = 171.53 × 1.5 × 1.5 = 385.95 kN.

An independent calculation of these numbers agrees with the module. In US the same footing gives qu = 10.75 ksf, qall,g = 3.583 ksf and qall,n = 3.459 ksf; in SI · tf, 52.47 t/m², 17.49 t/m² and 16.89 t/m². The same answer in three unit systems.

How each input changes the answer

Each row changes one thing in the example (all other inputs as in the example: B = 1.5 m, Df = 1 m, square, c = 15.2 kPa, φ = 20°, γ = 17.8 kN/m³, γsat = 19 kN/m³, Dw = 2 m, FS = 3). Pressures in kPa.

Changequqall,g qall,n
The example514.6171.5165.6
Strip footing
no shape factors
442.1147.4141.4
Circular footing506.4168.8162.9
Local shear
c′ and φ′ at two thirds
235.878.6172.68
B = 2.5 m
the water table is 1 m below the base, within B: γav = 12.63 kN/m³
528.0176.0170.1
B = 1 m
the water table is one width below the base, so the term uses γ
507.9169.3163.4
Df = 0.5 m
q = 8.9 kPa
454.6151.5148.6
Df = 1.5 m
q = 26.7 kPa; Df = B
574.5191.5182.6
Df = 0
q = 0, so net equals gross
388.4129.5129.5
c = 0165.055.0149.08
c = 30 kPa854.9285.0279.0
φ = 0°
Nc = 5.70, Nq = 1, Nγ = 0
130.443.4837.54
φ = 25°797.7265.9260.0
φ = 30°1,305435.1429.2
γ = 20 kN/m³
γsat stays 19
534.2178.1171.4
Dw = 0.5 m
water above the base
470.0156.7152.2
Dw = 1 m
water at the base
502.1167.4161.4
Dw = 4 m, or no water table
the same answer for both
520.9173.6167.7
FS = 2
qu does not depend on FS
514.6257.3248.4
FS = 4514.6128.6124.2
  • Friction angle moves the answer steeply: qu rises from 514.6 kPa at 20° to 1,305 kPa at 30°, about 2.5 times, because all three factors grow with φ.
  • Cohesion matters most at small φ: with c = 0 the example still carries 165.0 kPa, from the surcharge and self-weight terms.
  • Water lowers the capacity: a water table at the surface (Dw = 0) gives 438.0 kPa against 520.9 kPa with none.
  • Width has a modest effect here: only the self-weight term depends on B.

Messages and what they mean

A condition of the method is not met. The bar turns amber, names the problem and disables Analyze; hovering over it shows a shorter version. Change the inputs marked in red and the bar returns to normal.

The bar reading Cannot be analysed, Df = 2.00 m exceeds B = 1.50 m, with the explanation and a dimmed Analyze button.
The bar when the founding depth exceeds the width.
MessageWhat to do
Cannot be analysed — Df = 2.00 m exceeds B = 1.50 m
Terzaghi’s equation assumes a shallow footing, Df ≤ B.
Reduce Df, widen the footing, or use Meyerhof or Hansen. The module gives no result for a footing deeper than its width.
Cannot be analysed — γsat ≤ γw — the submerged unit weight would not be positive
A negative effective weight is not physical.
Check γsat; it must exceed 9.81 kN/m³. A value of 9.5 or of 9.81 gives this message.
Cannot be analysed — qu = … does not exceed the overburden q = … at the base level
The soil would fail under less than the pressure that already acts at the base, so there is no bearing capacity to report.
Give the soil some cohesion or friction, for example when c and φ are both zero.
Cannot analyse — 1 input error
for example: Friction angle (φ) must be at most 50°.
A dialog lists every value that is missing or out of range, such as Cohesion (c) is missing, Factor of safety (FS) must be at least 1, or Footing width / diameter (B) must be at least 0.05 m. Nothing is calculated until you correct them.
The dialog Cannot analyse, 1 input error, listing that the cohesion is missing.
The dialog for a missing value.

No bearing capacity. If qu does not exceed the overburden q (for example c = 0 and φ = 0), the bar turns amber with “Cannot be analysed — qu = … does not exceed the overburden q = … at the base level” and Analyze stays disabled; give the soil some cohesion or friction. No warnings. For this module’s single soil the Warnings list of a valid run reads “No warnings”.

Good practice

  • Check the footing is shallow. The equation applies when Df ≤ B; for a deeper footing use a method with depth factors.
  • Use service loads for qapplied and include the weight of the footing and of the soil above it; the module compares the pressure with the allowable value at the factor of safety you set.
  • Choose the failure mode on the soil. General shear for dense sand and stiff clay, local shear for loose sand and soft clay; the example drops from 514.6 to 235.8 kPa between the two.
  • Give the water table its real depth. It reduces qu when it reaches the failure zone.
  • One soil below the footing. The values you enter are taken for the whole failure zone; choose the values of the weaker soil within about one width under the base.
  • Vary one input at a time from the example to see its effect, as in the table above.
  • Gross with gross, net with net. Compare qapplied with the gross values and qapplied − q with the net ones.

Frequently asked questions

What does the Terzaghi module give?

The ultimate bearing capacity of a strip, square or circular footing, gross and net, the allowable pressures at your factor of safety, the load the footing can carry, the contribution of each term, the failure mechanism drawn to scale and, when you enter an applied pressure, PASS or FAIL. The example gives 514.6 kPa ultimate and 171.5 kPa gross allowable.

What is the difference between gross and net?

The gross pressures are the total pressure at the base. The net pressures are what the footing adds to the overburden q already acting at the base level: qu,net = qu − q. The gross allowable is qu / FS; the net allowable is (qu − q) / FS.

Do I have to enter the applied pressure?

No. Leave it empty and the module calculates the bearing capacity; the Design check then reads NOT CHECKED. Enter qapplied (V/A with service loads) to get PASS or FAIL for the gross and the net check.

Why does the module stop when Df is larger than B?

Terzaghi’s equation is for a shallow footing, Df ≤ B, so that the soil above the base acts as a surcharge. The bar says so and Analyze stays disabled. Reduce Df, widen the footing or use Meyerhof or Hansen.

What does Local shear do?

It replaces c by ⅔ c and φ by arctan(⅔ tan φ) and runs the same equation, for loose sand and soft clay. The example falls from 514.6 to 235.8 kPa.

How is the water table treated?

By its depth from the ground surface. Above the base it reduces the surcharge and uses the submerged unit weight in the self-weight term; within one width below the base the term uses a weighted average; deeper than that it has no effect. The Groundwater section shows the case.

Can I enter several soil layers?

No. The module takes one soil below the footing, with c, φ and γ. For a layered profile, enter the values of the weaker layer within about one width under the base.

What values does the module accept?

The width at least 0.05 m, the founding depth zero or more and not above the width, the cohesion zero or more, the friction angle from 0° to 50°, the unit weights at least 0.1 (the saturated one above 9.81 kN/m³), the water depth zero or more and the factor of safety at least 1. A missing or out-of-range value stops the analysis with a message that names it.

Can I drag or zoom the drawing?

No. The drawings have no drag handles and no zoom; change the values in the Model tab and the drawing follows. After Analyze the inputs are locked until you press Edit inputs.

Which units does it use?

SI · kN, SI · tf or US, switchable in the header at any time, even after Analyze. Pressures are in kPa, t/m² or ksf. The example gives 514.6 kPa, 52.47 t/m² or 10.75 ksf.

What does the report contain?

A cover with your project details and the answer, then six parts: introduction and scope, input data, the calculation step by step, results, summary and references, with the drawings. A seventh part, Warnings and notes, is added when an analysis carries a caution; this single-soil module raises none for its inputs. It is saved as a PDF or a Word file.

Does the module remember my inputs?

Yes. Every change is kept in the browser, and the page opens again on the model you last worked on, analysed if it was. Reset to defaults brings back the example; Save to file and Quick Save keep copies.