Skip to the manual
GeoTerva Free for 7 days

Passive earth pressure in an earthquake: user manual

Find the passive force that soil in front of a vertical wall can give while the ground shakes, with the horizontal and vertical seismic coefficients you choose: its size, its direction and the height at which it acts, for one soil or several layers, with a water table and a surcharge. This manual walks through the screen, every input, the results and the report, with worked examples you can reproduce.

Updated 20 October 2026 · GeoTerva user manual

What the module calculates

Passive, earthquake gives the passive force that the soil in front of a vertical wall can put up when the wall is pushed into it and the ground is shaking: the force per metre of wall, its direction and the height at which it acts. The shaking is taken as a pseudo-static load: a horizontal coefficient kh and a vertical coefficient kv, both entered by you, act on the soil wedge in front of the wall. In an earthquake the inertia of the wedge helps to push it out, so the passive resistance is lower than the static value.

The module follows Subba Rao and Choudhury (2005). For one soil without water the passive force is

Ppe = [ ½ γ H² Kpγ(e) + q H Kpq(e) + 2 c′ H Kpc′(e) ] / cos δ′

Kpγ(e) , Kpq(e) and Kpc′(e) are the passive coefficients for the weight of the soil, the surcharge and the cohesion, taken normal to the wall; the division by cos δ′ turns the normal force into the force inclined at the wall friction δ′. The module reads the coefficients for your φ′, δ′, kh and kv from the published curves and tables of the method; you do not look anything up. For several layers or a water table it builds the pressure along the wall layer by layer instead and adds the parts, as described under How the passive force is found.

What you can describe

  • A vertical wall of height H, with its back vertical and the ground surface in front of it level.
  • One to six layers of soil, each with its unit weights, friction angle φ′ (10° to 40°), wall friction δ′ (from φ′/2 to φ′) and cohesion c′.
  • The wall adhesion: none, or equal to the cohesion times tan δ′/tan φ′.
  • The earthquake: kh from 0 to 0.5, kv from 0 to kh (upward).
  • A level water table with restrained or free pore water, and a uniform surcharge on the surface.

The module gives the passive force, its inclination, its components and the height of its line of action, draws the pressure on the wall, plots the coefficient Kpγ(e) against kh, writes out the working and prepares a PDF or Word report.

Which module for which job

  • This module: passive resistance of a vertical wall in an earthquake, with kh and kv given.
  • Passive, log spiral gives the static passive force, with an inclined back and a sloping surface.
  • Mononobe–Okabe gives the active pressure in an earthquake.
  • Rankine, Rankine, sloping backfill and Coulomb give active and passive pressure without an earthquake; At rest gives the pressure behind a wall that does not move.
  • A load on the ground behind a wall is the subject of the Surcharge loads modules.

Before you start: what you need

Have these ready from your design:

WhatSourceNotes
The wall height HYour designThe height of the vertical back over which the passive pressure acts. At least 0.1 m.
The soil layersTests or correlationsFor each layer: the unit weight γ, with water also γsat (and γd for free pore water), φ′ from 10° to 40°, δ′ and c′, and the thickness, measured from the top of the wall.
The wall friction δ′Judgement or testsFrom φ′/2 to φ′ of each layer. A value outside that range stops the analysis.
The seismic coefficientsYour designkh from 0 to 0.5 and kv from 0 to kh. You enter them; the module has no map or code table.
The water tableGround investigationIf there is one: its depth below the top of the wall, and whether the pore water moves with the soil or not.
The surcharge qYour design loadingA uniform load on the surface in front of the wall. Zero for none.

Quick start in eight steps

  1. Open the module and choose the units

    Open Passive, earthquake from the Lateral Earth Pressure family. Pick SI · kN, SI · tf or US in the header; you can change it at any time.

  2. Describe the wall

    In Wall, choose the wall adhesion and enter the height H.

  3. Enter the soil

    In Soil layers, check the first layer in the table and change it, or fill the New layer form and press + Add layer for each further layer.

  4. Enter the earthquake

    In Earthquake, enter kh and kv.

  5. Add water and a surcharge if you have them

    In Groundwater choose Present, enter the depth zw and the pore water. In Surcharge enter q.

  6. Press Analyze

    Press Analyze at the foot of the Model tab. The bar reads Analysed — the earth pressure calculated and the inputs lock. The module stays on the Model tab and the Section view: open Results to read the answer and press Pressure to see the pressure on the wall.

  7. Read the answer

    Open the Results tab for the passive force, its line of action and its components; press Pressure above the drawing for the pressure on the wall and the force.

  8. Take the working and the report

    The Calculations tab shows every step with your numbers. The Report tab saves a PDF or a Word file.

The screen: four views of the wall

The layout is the one every GeoTerva module shares, described in the workspace guide. The drawing on the left has four views, chosen with the buttons above it; the tabs on the right hold the model and the answers.

The whole window after Analyze: the Section view with the wall and the soil on the left, the Results tab with the cards on the right.
The whole window after Analyze, with the Results tab open.
  • Section is a section through the wall and the soil: the wall, the level surface, the layers, the water table and the surcharge, and the height H. It shows the geometry only and follows the inputs as you type. Before Analyze it says “Not analysed yet: the drawing follows the inputs.”
  • Pressure shows, after Analyze, the passive pressure along the wall, the water pressure on it, the resultant Ppe with its inclination, its horizontal and vertical components and the height of its line of action.
  • Kpγ(e) against kh plots the coefficient Kpγ(e) for the φ′, δ′/φ′ and kv of the first layer against kh, with your kh marked. It appears after Analyze (“The chart appears after Analyze”).
  • 3D shows a length of the wall with the soil and, after Analyze, the force as an arrow.
Section view before Analyze: the wall 4.00 m high with its vertical back, the surcharge arrows, the level surface and the soil with its unit weight and angles written on it.
Section before Analyze: the geometry of the default example.
Pressure view after Analyze: the pressure on the wall, 299.0 at the top, the resultant 3608 kN/m at 40 degrees with its horizontal component 2764 and vertical component 2319, at 1.554 m above the base.
Pressure after Analyze.
The coefficient K p gamma (e) against k h: a falling line from 14.5 at k h = 0, with the point 13.20 at k h = 0.3 marked by a dashed line.
The coefficient against kh, drawn for the φ′, δ′/φ′ and kv of the first layer.
3D view after Analyze: a length of the wall, the soil in front of it and the force arrow labelled 3608 kN/m.
3D after Analyze.

The Show chips

Above the drawing a Show bar switches parts of the picture on and off. The Section view has Dimensions. The Pressure view has five: Pressure p, Resultant Ppe, Ph, Pv components, Water u and Dimensions. The other two views have no chips.

The Show bar of the Pressure view with its five chips, all switched on.
The Show bar of the Pressure view.

Zoom

At the lower right of the drawing, + enlarges it (100 %, 135 %, 182 %, … up to 800 %), − reduces it and the third button fits the whole drawing again. The mouse wheel over the drawing zooms in and out; once zoomed, drag the drawing with the mouse to move it. − and the fit button are greyed at 100 %.

Entering the model, section by section

The Model tab has a Model data section and five input sections: Wall, Soil layers, Earthquake, Groundwater and Surcharge. Click a title to open or close a section; Next and Back at the foot of a section walk you through them, and Analyze waits at the foot of the tab. Where a unit is shown twice or three times, such as m · ft, the units are those of SI · kN, SI · tf and US in turn, and equal ones are merged.

Model data

At the top of the tab you can name the model and keep it. Save to file… and Open file… keep the model in a file with the project. Quick Save… asks “Quick Save — a name for this version:”; the version is listed in the box below with its date. Choose it there and press Load to come back to it, or Delete to remove it (the module asks you to confirm). Reset to defaults puts the example back at once. Every change is also kept in this browser. If you reload after Analyze the results come back and the inputs are still locked; press Edit inputs to change them. Quick saves and model files also keep the analysed state. The model section says “Every change is kept in this browser, so the page opens again with the model you last worked on.”

The Model data section: the explanation, the model name box, the buttons Save to file, Open file, Quick Save and Reset to defaults, the list of quick saves with Load and Delete.
Model data: names, files and quick saves.

Wall

A choice and one number: the wall adhesion and the height of the wall. The back is vertical; the module does not take an inclined back. The ? beside each adhesion button opens a window that explains it and shows what it does to your force: with the example, Ppe = 3608.1 kN/m without adhesion and 3610.2 kN/m with adhesion equal to the cohesion times tan δ′/tan φ′.

The Wall section: the two adhesion buttons with their question marks, the height of the wall 4 m and the Next button.
Wall: the adhesion and the height.
Wall fields
FieldDefaultWhat to enter
Wall adhesionc′ₐ = 0Two buttons: no adhesion between the wall and a cohesive soil, or adhesion equal to the cohesion times tan δ′/tan φ′. Only the cohesion part of the force depends on this choice.
Height of the wall (vertical back) H
m · ft
4At least 0.1 m; a blank or smaller box stops the analysis.

Soil layers

A New layer form on top, a table of the layers below it. The first layer is already in the table. To add a layer, fill the form and press + Add layer: it goes to the bottom of the table. To change a layer, press its row: the form turns to the layer and Done closes it; the × at the end of a row removes a layer (a single layer cannot be removed). Up to six layers are allowed; the counter in the form reads “2 of 6” with two layers. The layers run from the top of the wall down, and the table lists the unit weights, φ′, δ′ and c′ of each (the saturated and dry unit weights show — until water is present). Layer 1 opens with γ 17.5, γsat 19.5, γd 16, φ′ 40°, δ′ 40° and c′ 10; the New layer form opens with H 2 m, γ 18, γsat 20, γd 16, φ′ 30°, δ′ 20° and c′ 0.

Fields of a layer
FieldDefaultWhat to enter
Name (optional)automaticShown on the drawing and in the tables; leave it blank for “Layer 1”, “Layer 2” and so on.
Thickness (vertical) H
m · ft
2Measured from the top of the wall; the layer boundaries are taken level. At least 0.01 m. The last layer has no thickness: it runs on below the heel.
Unit weight above the water table γ
kN/m³ · t/m³ · pcf
17.5At least 1.
Saturated unit weight γsat
kN/m³ · t/m³ · pcf
19.5At least 1, and above that of water (9.81 kN/m³) in a layer that is below the water table. Shown when the water table is present.
Dry unit weight γd
kN/m³ · t/m³ · pcf
16Above zero and not above γsat. Only the dry mass carries inertia below the water table when the pore water is free. Shown when the water table is present and the pore water is free.
Friction angle (10–40°, the range of the charts) φ′
°
40From 10° to 40°; outside it the analysis stops.
Angle of wall friction (φ′/2 ≤ δ′ ≤ φ′, the range of the charts) δ′
°
40From φ′/2 to φ′ of the same layer. The force of the layer is inclined at δ′ to the normal of the wall.
Cohesion c′
kPa · kg/cm² · psf
10Zero or more.
The Soil layers section with the New layer form and the table showing Layer 1 with 17.5, 40, 40 and 10.
Soil layers before any layer is added: the form and Layer 1.
The Soil layers section after a second layer was added: the table lists Layer 1 with a thickness of 2 and Layer 2 with a dash for the thickness.
Two layers: the last one has no thickness.
The Soil layers section with Layer 1 opened for editing in the form, with Done and Delete layer buttons.
Editing a layer: press its row in the table.

Earthquake

Two numbers, the horizontal and the vertical seismic coefficient. The section says that each chart curve ends where its passive resistance runs out, and that a kv between 0 and kh is interpolated linearly. The module takes kv as upward, the sense that reduces the weight of the soil and so the passive force.

The Earthquake section with kh 0.3, kv 0 and the Back and Next buttons.
Earthquake: two numbers.
Earthquake fields
FieldDefaultWhat to enter
Horizontal seismic coefficient kh
—
0.3From 0 to 0.5. Each curve of the method ends where its passive resistance runs out, so the usable kh is smaller for a smaller φ′: see Messages.
Vertical seismic coefficient (+ upward, reduces the weight; 0 ≤ kᵥ ≤ kₕ) kv
—
0From 0 to 0.5, and not above kh. Upward, the sense unfavourable to a passive force.

Groundwater

Two buttons choose Present or None. With water present, a second choice describes the pore water in the earthquake and the depth zw appears; each layer then asks for its saturated unit weight, and for its dry unit weight when the pore water is free. Below the table the layers weigh γsat − γw in the effective vertical stress, and the water pressure u = γw (z − zw) acts normal to the wall; γw is 9.81 kN/m³.

Groundwater fields
FieldDefaultWhat to enter
Water tableNoneChoose Present or None. It is on the side of the soil.
Pore water in the earthquakeRestrainedChoose Restrained (moves with the soil) or Free (highly permeable soil). The permeability limit between the two is 5×10⁻⁴ m/s. Shown when the water table is present.
Depth of the water table below the top of the wall zw
m · ft
2At least 0. A table at or below the base of the wall has no effect on the result. Shown when the water table is present.
The Groundwater section with the Present and None buttons, None chosen.
Groundwater with no water table.
The pore water choice, Restrained or Free, and the depth of the water table with 2 m.
With water present: the pore water and the depth.
The Soil layers section with water present: the table now shows the saturated unit weight of both layers and a dash for the dry unit weight.
Soil layers with water present: the saturated unit weights are filled in; the dry one is asked for with free pore water only.

Surcharge

One number: a uniform load on the level surface. It enters the force through its own coefficient Kpq(e) .

The Surcharge section with the uniform surcharge at 10 kPa.
Surcharge: one number.
Surcharge field
FieldDefaultWhat to enter
Uniform surcharge on the surface q
kPa · t/m² · ksf
10Zero or more; zero for none.

How the passive force is found

There is no method to choose: the module always uses the coefficients of Subba Rao and Choudhury (2005), which come from a curved failure surface analysed with the pseudo-static forces khW and kvW on the wedge. What your inputs decide is which coefficients are read and how they are combined.

The coefficients

For a layer the module reads Kpγ(e) and Kpq(e) from the curves of the method, which are drawn for φ′ = 10°, 20°, 30° and 40°, δ′/φ′ = 0.5 and 1, and kv = 0 and kv = kh. Between them the Calculations tab says the module interpolates linearly in kh and in δ′/φ′ and log-linearly in φ′, and linearly in kv between the curves of kv = 0 and kv = kh. Kpc′(e) comes from a table for the same four angles, in two columns: no adhesion, or adhesion equal to the cohesion times tan δ′/tan φ′.

For the example (φ′ = δ′ = 40°, kh = 0.3, kv = 0) the module gives Kpγ(e) = 13.20, Kpq(e) = 11.00 and Kpc′(e) = 5.950. All three are components normal to the wall.

One soil, no water

The formula of the first section applies. The weight part acts at H/3 above the base, the surcharge and cohesion parts at H/2, so the line of action is

z̄ = [ Pγ (H/3) + (Pq + Pc′ ) (H/2) ] / Ppe

The force is inclined at δ′ to the normal of the wall, turned upward: the wall pushes the soil up and the friction of the wall holds it down. Its components are Ppe,h = Ppe cos δ′, horizontal, into the wall, and Ppe,v = Ppe sin δ′, upward on the wall.

Layers or water: the pressure along the wall

With more than one layer, or with a water table above the base, the module works on the pressure instead. Each layer takes its own coefficients; the weight of the layers above it and the surcharge act on it as a surcharge, through Kpq(e) ; its own weight acts through Kpγ(e) ; its cohesion through Kpc′(e) . The pressure normal to the wall, per unit depth, is

σn = Kpq(e) σ′v,top + Kpγ(e) (σ′v − σ′v,top ) + 2 c′ Kpc′(e) , along the wall σn tan δ′ (upward)

The module sums the normal part N and the part along the wall T over the height of the wall. Then Ppe = √(N² + T²), the inclination is β = tan⁻¹(T/N) to the normal, Ppe,h = N and Ppe,v = |T|, and the line of action comes from the moment of N about the base. The Calculations tab writes out each step. For one soil without water this reduces to the formula above.

Water in the earthquake

  • Effective stress. Below the level water table the layers weigh γ′ = γsat − γw in σ′v, and the water pressure u acts normal to the wall and is added to the force as Pw.
  • Restrained pore water (soil of low permeability: the water moves with the soil). Below the water table the curves are read at a larger coefficient, kh,w = kh γsat / (γsat − γw). With the layered example below, kh = 0.1 is read at 0.196 in the layer under water.
  • Free pore water (highly permeable soil: the water does not move with the soil). Only the dry mass carries inertia, so kh,w = kh γd / (γsat − γw), and the hydrodynamic pressure of the water, ⅞ kh γw √(dw (z − zw)), is taken off the resistance. The module shows it as Hydrodynamic, taken off the resistance.
  • The reading is limited. The curves end at a largest kh; below the water table the larger kh,w must still be inside them (see Messages).

The Theory tab calls the layered form with a water table the module’s own extension of the single-soil solution. For one soil without water it gives the same force as the formula.

Analyze and read the results

Press Analyze. The bar changes to Analysed — the earth pressure calculated and says “The inputs are locked. Edit inputs clears the results; the unit system can still be changed.” It also carries Warnings (0) and Edit inputs. After Analyze the screen stays on the Model tab and the Section view. Open Results for the cards; press Pressure above the drawing to see the pressure and the force.

The green bar at the foot of the Model tab: Analysed, the earth pressure calculated, with the Warnings (0) and Edit inputs buttons.
The bar after Analyze.

One soil, no water

The Results tab of the example: Passive force 3,608 kN/m, line of action 1.554 m, horizontal component 2,764, vertical component 2,319, the three coefficients, and the table of values step by step.
The Results tab of the example.
CardSymbolThe example
Passive force with earthquakePpe 3,608 kN/m
Line of action above the basez̄1.554 m
Horizontal componentPpe,h 2,764 kN/m
Vertical component, upward on the wallPpe,v 2,319 kN/m
Coefficient, unit weight (normal)Kpγ(e) 13.20
Coefficient, surcharge (normal)Kpq(e) 11.00
Coefficient, cohesion (normal)Kpc′(e) 5.950

Under the cards a table of Values, step by step repeats the coefficients, the force, the line of action and the components. The force is per metre of wall, in kN/m, tf/m or kip/ft.

Layers or water

When there is more than one layer or water above the base, the cards are Passive force with earthquake, Line of action above the base, Inclination to the normal of the wall (β), Horizontal component and Vertical component, upward on the wall. With water a card From the water (normal to the wall) (Pw) is added, and with free pore water Hydrodynamic, taken off the resistance (Pwd ). Under the cards the tab lists Values, step by step, The chart coefficients of the layers, Pressure on the wall and Force of each layer, instead of the three coefficient cards.

The Results tab of the layered example with water: passive force 1,859 kN/m, line of action 2.099 m, inclination 33.71 degrees, horizontal component 1,547, vertical component 1,032 and the water 19.62 kN/m.
The Results tab of the layered example in the worked example below.

Using the numbers

  • Ppe is the force of the soil on the wall per unit length of wall, inclined at δ′ (or β) to the normal of the wall, turned upward.
  • The module gives the passive force during the earthquake; combine it with the other forces on the wall in your wall calculation.
  • Changing the unit system after Analyze re-states the cards, the drawing and the report without a new run. Edit inputs unlocks the model and clears the results.

The Calculations tab, the report and the Theory tab

The Calculations tab opens with Given and what is sought, then numbers the steps. For one soil without water they are Coefficients, Passive force, Line of action and Components of the force, then the Answer. For layers or water they are Coefficients of each layer (with a table of the φ′, δ′, kh read and the three coefficients of each layer and zone), Pressure on the wall (the σ′v, σn and u at each level, with the worked arithmetic) and Force, its direction and line of action (the N and T of each layer), then the Answer.

The Calculations tab, Step 2, Passive force: the formula, then 1,847.86 plus 440.12 plus 476.00 divided by cos 40 degrees equals 3,608.12 kN/m, and the answer 3,608 kN/m.
Step 2 for the example: the three parts and their sum.
The Calculations tab, Step 2, Pressure on the wall, for the layered example: the pressure at the base of each layer written out, and the table of the vertical stress, the normal pressure and the water pressure at each level.
Step 2 for the layered example with water.
The Calculations tab, Step 3, Force, its direction and line of action, for the layered example: the sums N and T, the resultant, the angle and the components.
Step 3 for the layered example.

The report

In the Report tab fill in the cover: project, location, client, report number, date, prepared by, title or qualification, checked by, and optional notes. The details are kept in this browser and saved with the model file. Save as PDF and Download Word (.docx) make the report; the preview below the buttons is the report itself.

The report has a summary cover and six parts: 1 Introduction and scope, 2 Input data, 3 Calculation (the steps of the Calculations tab), 4 Results, 5 Summary and 6 References. It carries the Section, Pressure, coefficient and 3D drawings, states the units with their conversion constants, and gives the warnings and notes when there are any.

The Report tab: the cover form with project, location, client, report number, date, prepared by, title, checked by and notes, and the buttons Save as PDF and Download Word.
The Report tab: the cover details and the two download buttons.

The Theory tab

The Theory tab has five sections, with Open all and Close all above them: The pseudo-static passive force; The coefficients; Layers, water and surcharge; Worked example; and References. It writes the formula, the line of action and the layered pressure, and the reading of the coefficients below the water table, as used in the Calculations.

Worked examples

The module’s own example

The module opens on this example, so you can follow the numbers on your own screen.

Inputs of the example
SectionInputValue
WallAdhesion, heightc′a = 0, H = 4 m
Soil layersOne layerγ = 17.5 kN/m³, φ′ = 40°, δ′ = 40°, c′ = 10 kPa
Earthquakekh, kv0.3, 0
Groundwater, Surcharge—None, q = 10 kPa

The Calculations tab gives the coefficients Kpγ(e) = 13.20, Kpq(e) = 11.00, Kpc′(e) = 5.950, and then

½ γ H² Kpγ(e) = 1847.86, q H Kpq(e) = 440.12, 2 c′ H Kpc′(e) = 476.00 (kN/m)
Ppe = (1847.86 + 440.12 + 476.00) / cos 40° = 3,608 kN/m

A hand check: ½ × 17.5 × 16 = 140 and 140 × 13.199 = 1847.9; 10 × 4 × 11.003 = 440.1; 2 × 10 × 4 × 5.950 = 476; the sum 2764.0 divided by cos 40° = 0.7660 gives 3608.1. The weight part acts at H/3 and the other two at H/2, so

z̄ = (2412.21 × 1.3333 + 1195.91 × 2) / 3608.12 = 1.554 m above the base

The force is inclined at δ′ = 40° to the normal, so Ppe,h = Ppe cos 40° = 2,764 kN/m, which is the sum 2764.0 of the three parts, and Ppe,v = Ppe sin 40° = 2,319 kN/m, upward.

The same example in other units

Switch to SI · tf: the module gives Ppe = 367.9 tf/m at z̄ = 1.554 m (3608.1 kN/m ÷ 9.80665 = 367.9 tf/m). Switch to US: Ppe = 247.2 kip/ft at z̄ = 5.099 ft, with Ppe,h = 189.4 and Ppe,v = 158.9 kip/ft. The coefficients stay 13.20, 11.00 and 5.950: they have no units.

A check in US units, typed in

Switch to US and enter H = 13 ft, one layer with γ = 110 pcf, φ′ = δ′ = 35° and c′ = 200 psf, kh = 0.2 and q = 0.2 ksf. The module gives Kpγ(e) = 8.533, Kpq(e) = 7.435 and Kpc′(e) = 4.511. By hand: ½ × 110 × 13² × 8.533 = 79 312 lb/ft = 79.31 kip/ft; 0.2 × 13 × 7.435 = 19.33; 2 × 0.2 × 13 × 4.511 = 23.46 (cohesion 200 psf = 0.2 ksf). Their sum 122.10 kip/ft divided by cos 35° = 0.8192 gives Ppe = 149.1 kip/ft, and the line of action is 5.093 ft.

Two layers with water, restrained pore water

Keep the example, set kh = 0.1 (the water table needs it: see Messages), choose Present with zw = 2 m and Restrained, and add a second layer with γ = 18 kN/m³, γsat = 20, φ′ = 32°, δ′ = 22° and c′ = 0. Layer 1 (0 to 2 m) is the example’s soil; its γsat of 19.5 kN/m³ is the default.

Inputs of the layered example
Layerγ, γsat (kN/m³)φ′, δ′, c′
Layer 1 (H = 2 m)17.5, 19.540°, 40°, 10 kPa
Layer 2 (to the heel)18, 2032°, 22°, 0

Press Analyze. Below the water table the curves are read at kh,w = 0.1 × 20 / (20 − 9.81) = 0.196 in Layer 2, and the module gives Kpγ(e) = 14.110 and Kpq(e) = 11.075 for Layer 1 (read at 0.1), and 5.352 and 5.163 for Layer 2. The pressure on the wall is built from them. At the base of Layer 1, σ′v = 10 + 17.5 × 2 = 45 kPa and

σn = 11.075 × 10 + 14.110 × (45 − 10) + 2 × 10 × 5.950 = 723.6 kPa

At the top of Layer 2 the surcharge of everything above acts through Kpq(e) : σn = 5.163 × 45 = 232.3 kPa. At the base, σ′v = 45 + (20 − 9.81) × 2 = 65.38 kPa and σn = 5.163 × 45 + 5.352 × 20.38 = 341.4 kPa, with the water pressure u = 9.81 × 2 = 19.62 kPa. The normal forces of the layers are the areas of the pressure: (229.8 + 723.6)/2 × 2 = 953.4 kN/m and (232.3 + 341.4)/2 × 2 = 573.7 kN/m, and the water Pw = ½ × 19.62 × 2 = 19.62 kN/m, so N = 1546.7 kN/m. Along the wall T = 953.35 tan 40° + 573.71 tan 22° = 800.0 + 231.8 = 1031.8 kN/m, upward. Then

Ppe = √(1546.7² + 1031.8²) = 1,859 kN/m, β = tan⁻¹(1031.8 / 1546.7) = 33.71°, z̄ = 2.099 m

The module gives Ppe,h = 1,547 kN/m, Ppe,v = 1,032 kN/m and Pw = 19.62 kN/m. The same soil with Free pore water (the dry unit weight of Layer 1 is the default 16 kN/m³, that of Layer 2 is 16 kN/m³) gives Ppe = 1,864 kN/m, with the hydrodynamic pressure of 2.289 kN/m taken off (7/12 × 0.1 × 9.81 × 2² = 2.289 by hand). Without water the layers give 1,954 kN/m, and restrained water with kv = 0.05 gives 1,770 kN/m.

Pressure view of the layered example: the stepped pressure on the wall with 299.9 at the top and 368.2 at the base, the water table, the water pressure 19.62, the resultant 1859 kN/m inclined 33.7 degrees at 2.099 m above the base and its components 1547 and 1032.
The Pressure view of the layered example: the pressure steps at the layer boundary and the water adds to the force.

How each input changes the answer

Each row changes one thing in the example (H = 4 m, γ = 17.5 kN/m³, φ′ = δ′ = 40°, c′ = 10 kPa, q = 10 kPa, kh = 0.3, kv = 0, no water) and runs the module again. The numbers are the ones the module gives, so you can reproduce any row.

One soil without water: one change at a time
ChangeKpγ(e) Ppe Ppe,h / Ppe,v
The example13.203,6082,764 / 2,319
kh = 0 (no earthquake)14.493,8502,949 / 2,475
kh = 0.114.113,7782,894 / 2,429
kh = 0.213.663,6932,829 / 2,374
kh = 0.412.743,5232,699 / 2,265
kh = 0.4612.473,4722,660 / 2,232
kv = 0.0512.283,4102,613 / 2,192
kv = 0.1510.443,0152,310 / 1,938
kv = kh = 0.37.6872,4221,855 / 1,557
φ′ = δ′ = 30°4.9451,3451,165 / 672.5
φ′ = 35°, δ′ = 25°6.6071,6461,492 / 695.7
δ′ = 30° (φ′ = 40°)10.852,6732,315 / 1,336
δ′ = 20° (φ′/2)8.4951,9851,865 / 678.9
c′ = 013.202,9872,288 / 1,920
c′ = 20 kPa13.204,2293,240 / 2,719
Adhesion equal to the cohesion times tan δ′/tan φ′13.203,6102,766 / 2,321
H = 6 m13.207,2215,532 / 4,642
H = 2 m13.201,201920.0 / 772.0
q = 013.203,0342,324 / 1,950
q = 20 kPa13.204,1833,204 / 2,689
γ = 20 kN/m³13.203,9533,028 / 2,541

Forces in kN/m.

What the rows show:

  • kh lowers the force slowly, kv lowers it fast. From kh = 0 to 0.4 the force falls from 3,850 to 3,523 kN/m, less than 9 %; kv = 0.05 alone takes 3,410 kN/m, and kv = kh = 0.3 takes 2,422 kN/m.
  • φ′ and δ′ are the strongest inputs. At φ′ = δ′ = 30° the force is 1,345 kN/m, less than half of the 40° value; at φ′ = 40° halving δ′ from 40° to 20° takes it from 3,608 to 1,985 kN/m.
  • Cohesion and surcharge add to the force and lift its line of action. c′ = 0 gives z̄ = 1.462 m against 1.554 m; the weight part acts at H/3, the others at H/2.
  • The adhesion choice changes little here: 3,610 against 3,608 kN/m; with c′ = 0 it changes nothing.
  • The height works through H². H = 6 m gives 7,221 kN/m against 3,608 kN/m at 4 m; the surcharge and cohesion parts grow with H, the weight part with H².

In the second table the layered cases use the two layers of the worked example (restrained pore water unless stated); the single-soil cases use the example with the water table as named, restrained unless stated.

Layers and water
CasePpe β, z̄Pw
Two layers, dry, kh = 0.3 (second: 30°, 20°)1,74333.63°, 2.129 m—
Two layers, dry, kh = 0.11,95433.35°, 2.026 m—
The same with the water table at 2 m, restrained1,85933.71°, 2.099 m19.62
The same, free pore water1,86433.70°, 2.095 m19.62
The same, restrained, kv = 0.051,77033.73°, 2.105 m19.62
One soil, dry, kh = 0.13,77840°, 1.545 m—
One soil, water 2 m, kh = 0.13,45139.79°, 1.621 m19.62
One soil, water 1 m, kh = 0.13,10639.48°, 1.653 m44.15
One soil, water 2 m, kh = 0.23,32039.78°, 1.637 m19.62
One soil, water 2 m, kh = 0.2, free3,35639.83°, 1.630 m19.62

Ppe and Pw in kN/m.

A water table lowers the force (about 9 % here: 3,778 to 3,451 kN/m for the single soil at kh = 0.1) and adds Pw; the higher the table, the larger Pw and the lower the force. Restrained and free pore water differ by about 1 % in these runs. For the single soil without water the inclination is δ′ (40° here).

Messages: when the module stops

The module checks the numbers it needs. When one of them cannot be used it stops and nothing is calculated.

For a condition of the solution the bar at the foot of the Model tab turns brown and reads Cannot be analysed followed by the message. For a value outside its range the box is marked in red and the bar stays Not analysed; press Analyze and a window opens: “Cannot analyse — 1 input error” (or “2 input errors”) with the boxes named, or “Cannot analyse — a condition of the solution is not met”. Both add: “Nothing was calculated. Change the inputs marked in red, then press Analyze again.”

The window Cannot analyse, a condition of the solution is not met, with the message Layer 1: kh beyond the charts, the curves for phi 40, delta/phi 1.00 and kv 0 end at kh 0.463, and the explanation.
The window that Analyze opens for kh = 0.5.
The bar at the foot of the Model tab in brown, reading Cannot be analysed and the Analyze button.
The bar after a stop.

Conditions of the solution

WhenMessage and what to do
kh is beyond the end of the curves of the layer“Layer 1: kₕ beyond the charts.” The message gives where the curves end: for φ′ = 40°, δ′/φ′ = 1 and kv = 0 they end at kh = 0.463, so kh = 0.46 runs and 0.47 stops. With φ′ = δ′ = 20° they end at 0.279. Use a smaller kh or a larger φ′.
kh read below the water table is beyond the curves“Layer 1 (below the water table): kₕ beyond the charts.” With the example and water at 2 m, restrained, the curves are read at kh,w = 0.604 and the module stops; free pore water is read at 0.495 and stops too. Use a smaller kh (the layered example uses 0.1).
kv is above kh“kᵥ above kₕ.” The curves are for kv = 0 and kv = kh and are not extended beyond. Use 0 ≤ kv ≤ kh.
δ′/φ′ is outside 0.5 to 1“Layer 1: δ′/φ′ outside 0.5–1.” For φ′ = 40°, δ′ = 20° runs and 19° stops. The message gives the range: here 20.0° to 40°.
The layers above the last reach the base“The layers above the last one already reach the base.” The last layer would not meet the wall. Reduce the thicknesses or the number of layers.
Water present and γsat not above 9.81 kN/m³“Layer 1: the saturated unit weight is not above that of water.” Enter the saturated unit weight of the soil.
Free pore water and γd not above zero, or above γsat“Layer 1: the dry unit weight γd must be above zero and not above γsat.” Enter γd of the layer.

Values outside their range

A box outside its limits stops the analysis with a message that names it, for example “Height of the wall (vertical back) (H) must be at least 0.1 m.”, “Friction angle (10–40°, the range of the charts) (φ′1) must be at most 40°.”, “Horizontal seismic coefficient (kh) must be at most 0.5.”, “Uniform surcharge on the surface (q) must be at least 0 kPa.” An empty box reads “… is missing.” Two errors at once are counted: φ′ = δ′ = 41° gives “2 input errors”. The limits are in the field tables above.

Warnings

The bar carries Warnings (0); pressing it opens a window that says “No warnings — the assumptions of the solution hold for these inputs.” In the examples in this manual the window reads this.

The Warnings (0) window: No warnings, the assumptions of the solution hold for these inputs, with a Close button.
The Warnings window.

Good practice and common mistakes

  • Choose kh and kv from your design basis. They are inputs; the module does not derive them. The force depends on them (3,850 kN/m at kh = 0, 3,608 at 0.3, 2,422 with kv = 0.3).
  • Pick δ′ deliberately. It is limited to φ′/2 to φ′ and changes the force a great deal: 1,985 kN/m at φ′/2 against 3,608 kN/m at φ′ for the example.
  • Use the lower force if you are unsure. Run the analysis at both ends of the range of δ′ and of kv and use the case that governs your design.
  • Keep c′ in view. Cohesion is a large part of the force in the example (476 of 2764 kN/m before the division by cos δ′); the adhesion choice and a smaller c′ show how much your result relies on it.
  • Match the force to the movement your wall allows. The passive force is the resistance at failure; the movement needed to mobilise it, and the factors your design method requires, are yours to apply.
  • Take the vertical component with care. Ppe,v acts upward on the wall; whether you may count on it is a design decision.
  • Check the soil in front of the wall. It is often disturbed, softened or removed later; the first layers carry little of the force but they are the first to go.
  • Use layers for real changes. Add a layer when the soil changes; the thicknesses add up from the top of the wall, and the last layer takes the rest.
  • Keep the angles inside the range. φ′ from 10° to 40°, δ′ from φ′/2 to φ′, and kh inside the end of the curves; with water, check kh,w too.
  • Save your model. The module keeps the last model in the browser, but the file from Save to file… is the record that goes with the project.

Frequently asked questions

How is the passive force in an earthquake calculated?

For one soil without water, Ppe = [½ γ H² Kpγ(e) + q H Kpq(e) + 2 c′ H Kpc′(e) ] / cos δ′, with the coefficients of Subba Rao and Choudhury (2005) read for your φ′, δ′, kh and kv. For the module’s example (H = 4 m, φ′ = δ′ = 40°, c′ = 10 kPa, q = 10 kPa, kh = 0.3) it is 3,608 kN/m.

Where do I get kh and kv?

From your design basis. The module takes them as inputs: kh from 0 to 0.5 and kv from 0 to kh, upward. It does not look them up from a map or a code table.

Why does the module stop with “kₕ beyond the charts”?

The curves of the method end at a largest kh where the passive resistance runs out, and the module does not extend them. For φ′ = δ′ = 40° and kv = 0 they end at 0.463; for 20° at 0.279. The message gives the value. Use a smaller kh or a larger φ′. With a water table the curves are read at a larger kh,w below it, so the limit on kh is usually lower.

Why must δ′ be between φ′/2 and φ′?

The coefficients are given for δ′/φ′ = 0.5 and 1 and the module interpolates between them; it does not extend beyond. δ′ below φ′/2 (19° for φ′ = 40°) or above φ′ stops the analysis.

What do restrained and free pore water mean?

Restrained pore water moves with the soil (low permeability, below 5×10⁻⁴ m/s): the curves are read at kh,w = kh γsat / (γsat − γw). Free pore water does not (highly permeable soil): they are read at kh γd / (γsat − γw) and the hydrodynamic pressure of the water is taken off the resistance. In the layered example the two give 1,859 and 1,864 kN/m.

Can I use several layers?

Yes, up to six, each with its own γ, φ′, δ′ and c′. Each takes its own coefficients, and the weight above it acts on it as a surcharge. The last layer runs to the heel; the layers above it must be shorter than the wall.

Is the force horizontal?

No. It is inclined at δ′ to the normal of the wall (at β for layers or water), turned upward. The module gives the horizontal component Ppe,h (2,764 kN/m for the example) and the vertical one Ppe,v (2,319 kN/m).

Where does the force act?

For one soil without water the weight part acts at H/3 above the base and the surcharge and cohesion parts at H/2, so the line of action is between: 1.554 m for the example. With layers or water the module finds it from the moment of the normal pressure about the base: 2.099 m in the layered example.

Can the wall be inclined or the ground sloping?

No. The module is for a vertical back and a level surface. The Section view says so (“vertical back”, “level backfill”). For an inclined back or a sloping surface without an earthquake use Passive, log spiral (granular soil).

Which units does it use?

SI · kN, SI · tf or US, switchable in the header at any time, even after Analyze. The force is in kN/m, tf/m or kip/ft. The example gives 3,608 kN/m, 367.9 tf/m or 247.2 kip/ft.

Does the module remember my inputs?

Yes. Every change is kept in this browser, so the page opens again with the model you last worked on. Reset to defaults brings back the example; Save to file… and Quick Save… keep versions you name.

Can I drag the wall or the water table on the drawing?

No. The drawing follows the Model tab and has no handles. You can zoom with the + and − buttons or the mouse wheel, pan a zoomed drawing by dragging it, and fit it with the third button.

What does the report contain?

A cover with your project details and a summary, then six parts: introduction and scope, input data, the calculation step by step, results, summary and references, with the Section, Pressure, coefficient and 3D drawings. It is saved as a PDF or a Word file.