1Surcharges and the rigid wallThe elastic stress, doubled.
A load on the ground behind a wall raises the horizontal stress in the soil, and with it the pressure on the wall. A load of limited extent — a column footing, a line of wheels, a strip footing or a stockpile — is handled with the elastic solutions for a load on a half-space: Boussinesq’s for a point load (see Boussinesq point load), Flamant’s (1892) for a line load, and its integral for a strip. Their horizontal stress σx on the vertical plane of the wall is the pressure on a wall so flexible that it does not disturb the soil.
A wall that does not yield is a plane across which the soil cannot move. Mindlin (1936) pointed out that it can be represented by an equal image load placed symmetrically on the other side of the wall, which doubles the half-space stress. Spangler (1938) measured the pressures that concentrated loads put on a retaining wall, and Terzaghi (1954) fitted to such measurements the chart given below. The elastic pressures are already lateral pressures: they are not multiplied by Ka. A uniform surcharge q over the whole retained surface is the exception: it adds Kq at every depth, K0q for a wall that does not yield or Kaq for one that does (see earth pressure coefficients).
With H the height of the wall, x the distance of the load from the back of the wall and z the depth, the solutions are written in m = x/H and n = z/H.
2A point loadThe rigid-wall solution and Terzaghi’s chart.
For a point load Q at the distance x, on the section of the wall through the load (y = 0), the doubled Boussinesq stress with Poisson’s ratio 0.5 is
It peaks at z = x/2, and its resultant over the height of the wall, per metre at the section of the load, is
The solution is singular at the wall, so the GeoTerva module calculates a load nearer than 0.30 m at 0.30 m. Terzaghi’s (1954) chart, as carried by the NAVFAC DM-7.02 design manual, gives instead
and spreads the pressure along the wall by σ′h = σhcos²(1.1θ), θ being the angle in plan from the section of the load. A load nearer than 0.4H is treated as if it stood at 0.4H.
3A line loadParallel to the wall.
For a long line load P (force per metre) parallel to the wall at the distance x, the rigid-wall solution is twice Flamant’s horizontal stress:
It peaks at z = x/√3. Terzaghi’s chart keeps this expression for m > 0.4 and, for a line load nearer the wall, freezes it at m = 0.4:
4A strip loadA uniform pressure on a strip parallel to the wall.
For a uniform pressure q on a strip from x1 to x2 behind the wall, the two edges of the strip subtend at depth z the angle β, whose bisector makes the angle α with the vertical:
and the pressure on a rigid wall, twice the elastic stress of the strip load, is
For a strip that starts at the wall, σh = q at the surface. A wall that can yield is often given half these values, the undoubled elastic stress; the GeoTerva strip load module offers both.
5Tables of the pressure and the resultantDimensionless, for any wall.
| n | Elastic, m = 0.2 | Elastic, m = 0.4 | Elastic, m = 0.6 | Elastic, m = 1.0 | Chart, m ≤ 0.4 | Chart, m = 0.6 |
|---|---|---|---|---|---|---|
| 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
| 0.1 | 6.833 | 1.282 | 0.413 | 0.093 | 0.570 | 0.126 |
| 0.2 | 4.220 | 1.708 | 0.679 | 0.173 | 1.400 | 0.398 |
| 0.3 | 1.881 | 1.467 | 0.759 | 0.231 | 1.613 | 0.629 |
| 0.4 | 0.854 | 1.055 | 0.705 | 0.264 | 1.367 | 0.725 |
| 0.5 | 0.422 | 0.710 | 0.591 | 0.273 | 1.016 | 0.702 |
| 0.6 | 0.226 | 0.470 | 0.469 | 0.266 | 0.717 | 0.615 |
| 0.7 | 0.131 | 0.314 | 0.361 | 0.247 | 0.500 | 0.508 |
| 0.8 | 0.080 | 0.214 | 0.275 | 0.222 | 0.350 | 0.408 |
| 0.9 | 0.052 | 0.148 | 0.209 | 0.195 | 0.249 | 0.322 |
| 1.0 | 0.035 | 0.105 | 0.159 | 0.169 | 0.179 | 0.253 |
Elastic: the rigid-wall (doubled) Boussinesq solution. Chart: Terzaghi (1954). Multiply by Q/H² for the pressure. Values computed by GeoTerva with the functions of its point load module.
| n | Elastic, m = 0.2 | Elastic, m = 0.4 | Elastic, m = 0.6 | Elastic, m = 1.0 | Chart, m ≤ 0.4 |
|---|---|---|---|---|---|
| 0.0 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
| 0.1 | 2.037 | 0.705 | 0.335 | 0.125 | 0.702 |
| 0.2 | 1.592 | 1.019 | 0.573 | 0.235 | 1.015 |
| 0.3 | 0.904 | 0.978 | 0.679 | 0.321 | 0.974 |
| 0.4 | 0.509 | 0.796 | 0.678 | 0.378 | 0.793 |
| 0.5 | 0.303 | 0.606 | 0.616 | 0.407 | 0.604 |
| 0.6 | 0.191 | 0.452 | 0.531 | 0.413 | 0.450 |
| 0.7 | 0.127 | 0.338 | 0.444 | 0.401 | 0.336 |
| 0.8 | 0.088 | 0.255 | 0.367 | 0.379 | 0.254 |
| 0.9 | 0.063 | 0.195 | 0.301 | 0.350 | 0.194 |
| 1.0 | 0.047 | 0.151 | 0.248 | 0.318 | 0.151 |
For m > 0.4 the chart is the elastic solution. Multiply by P/H for the pressure. Values computed by GeoTerva with the functions of its line load module.
| m = x/H | Point, elastic: PHH/Q | height/H | Point, chart: PHH/Q | height/H | Line, elastic: PH/P | height/H | Line, chart: PH/P | height/H |
|---|---|---|---|---|---|---|---|---|
| 0.1 | 3.180 | 0.901 | 0.787 | 0.587 | 0.630 | 0.861 | 0.547 | 0.608 |
| 0.2 | 1.580 | 0.810 | 0.787 | 0.587 | 0.612 | 0.754 | 0.547 | 0.608 |
| 0.3 | 1.036 | 0.730 | 0.787 | 0.587 | 0.584 | 0.672 | 0.547 | 0.608 |
| 0.4 | 0.755 | 0.663 | 0.787 | 0.587 | 0.549 | 0.608 | 0.547 | 0.608 |
| 0.5 | 0.580 | 0.607 | 0.596 | 0.525 | 0.509 | 0.558 | 0.509 | 0.558 |
| 0.6 | 0.458 | 0.562 | 0.457 | 0.476 | 0.468 | 0.519 | 0.468 | 0.519 |
| 0.8 | 0.301 | 0.496 | 0.277 | 0.407 | 0.388 | 0.464 | 0.388 | 0.464 |
| 1.0 | 0.206 | 0.453 | 0.174 | 0.363 | 0.318 | 0.429 | 0.318 | 0.429 |
| 1.5 | 0.090 | 0.396 | 0.061 | 0.308 | 0.196 | 0.383 | 0.196 | 0.383 |
| 2.0 | 0.045 | 0.371 | 0.025 | 0.285 | 0.127 | 0.364 | 0.127 | 0.364 |
Point load: PH per metre of wall at the section of the load. Values computed by GeoTerva.
| n | x1 = 0, x2 = 0.5H | x1 = 0.25H, x2 = 0.75H | x1 = 0.5H, x2 = H |
|---|---|---|---|
| 0.0 | 1.000 | 0.000 | 0.000 |
| 0.1 | 0.752 | 0.294 | 0.122 |
| 0.2 | 0.538 | 0.416 | 0.214 |
| 0.3 | 0.375 | 0.409 | 0.264 |
| 0.4 | 0.260 | 0.354 | 0.278 |
| 0.5 | 0.182 | 0.291 | 0.268 |
| 0.6 | 0.129 | 0.235 | 0.246 |
| 0.7 | 0.094 | 0.188 | 0.218 |
| 0.8 | 0.069 | 0.150 | 0.190 |
| 0.9 | 0.053 | 0.121 | 0.164 |
| 1.0 | 0.041 | 0.098 | 0.141 |
| PH/(qH) | 0.295 | 0.254 | 0.205 |
| height/H | 0.741 | 0.577 | 0.487 |
Rigid wall (doubled elastic stress). Values computed by GeoTerva with the functions of its strip load module.
The tables show what the elastic solutions mean in practice: a load close to the wall gives a sharp peak just below the surface and a resultant high on the wall, while the same load farther back spreads its pressure deeper and loads the wall less. Near the wall the elastic point-load solution gives a far higher peak than the chart, which caps the distance at 0.4H.
6Worked exampleThree loads behind a 6 m wall.
A wall retains H = 6 m of soil. Behind it stand a column footing taken as a point load Q = 150 kN at x = 2.0 m (m = 0.333), a line load P = 40 kN/m parallel to the wall at x = 1.5 m (m = 0.250) and a stockpile q = 25 kPa on a strip from 3.0 to 6.0 m. The wall does not yield, so the rigid-wall solutions apply; the pressures are added on the section through the point load.
| z (m) | Point load | Line load | Strip | Total |
|---|---|---|---|---|
| 0.0 | 0.00 | 0.00 | 0.00 | 0.00 |
| 0.5 | 7.69 | 9.17 | 2.57 | 19.43 |
| 1.0 | 10.25 | 10.85 | 4.69 | 25.78 |
| 1.5 | 8.80 | 8.49 | 6.10 | 23.39 |
| 2.0 | 6.33 | 5.87 | 6.81 | 19.01 |
| 2.5 | 4.26 | 3.97 | 6.95 | 15.17 |
| 3.0 | 2.82 | 2.72 | 6.71 | 12.25 |
| 3.5 | 1.88 | 1.91 | 6.25 | 10.05 |
| 4.0 | 1.28 | 1.38 | 5.69 | 8.35 |
| 4.5 | 0.89 | 1.02 | 5.11 | 7.02 |
| 5.0 | 0.63 | 0.77 | 4.54 | 5.94 |
| 5.5 | 0.46 | 0.60 | 4.01 | 5.06 |
| 6.0 | 0.34 | 0.47 | 3.53 | 4.34 |
| PH (kN/m) | 23.12 | 23.97 | 30.72 | 77.81 |
| Height above the base (m) | 4.24 | 4.26 | 2.92 | 3.72 |
The point load’s resultant is per metre of wall at its own section. Values computed by GeoTerva with the functions of its surcharge modules.
- Point load: the peak, 10.25 kPa, is at z = x/2 = 1.00 m; PH = [150 / (π × 6)] × [1/0.333 − 0.333²/(1 + 0.333²)3/2] = 23.12 kN/m, 4.24 m above the base. Terzaghi’s chart (m ≤ 0.4) would give 19.69 kN/m, 3.52 m above the base.
- Line load: the peak, 11.03 kPa, is at z = x/√3 = 0.87 m; PH = (2 × 40/π) / (1 + 0.250²) = 23.97 kN/m (21.88 kN/m by the chart).
- Strip: PH = (2 × 25 × 6/π) × [tan−1(6.0/6) − tan−1(3.0/6)] = 30.72 kN/m, 2.92 m above the base; the pressure peaks at 6.96 kPa at z = 2.40 m.
Together the three loads add 77.8 kN/m acting 3.72 m above the base, on top of the earth pressure of the retained soil. In a sheet-pile design the same pressures enter the net pressure diagram (see cantilever sheet pile in sand and anchored sheet pile, free earth support); the GeoTerva surcharge modules draw each diagram in elevation, plan and 3D.
7QuestionsShort answers.
Why is the elastic surcharge pressure doubled for a rigid wall?
A wall that cannot move stops the soil from moving across its plane. Mindlin (1936) showed that this is equivalent to an equal image load on the other side of the wall, which doubles the horizontal stress of the half-space. A wall that yields sees less, often taken as the undoubled stress.
Is a surcharge pressure multiplied by Ka?
Not the elastic pressures of point, line and strip loads: they are lateral pressures already. Only a uniform surcharge q over the whole retained surface is turned into a lateral pressure by a coefficient, K0q for a wall that does not yield or Kaq for one that does.
When should Terzaghi’s chart be used instead of the elastic solution?
The chart was drawn from measured pressures and avoids the very high peaks the elastic point-load solution gives for a load close to the wall, by treating every load nearer than 0.4H as if it stood at 0.4H. Beyond 0.4H the chart and the elastic solution coincide for a line load; for a point load the chart gives about the same resultant at m = 0.5–0.6 and a smaller one farther back.