GeoTerva Open the module

Theory · Retaining Walls

Gravity retaining wall design: pressure, stability and bearing of a masonry or concrete wall

How a gravity wall of stone masonry or plain concrete on a stepped footing is analysed: the free body, the earth pressure by three theories, water, surcharge, the earthquake, the passive resistance in front, and the four stability checks, with a wall worked step by step.

The module runs online, in your browser, on a phone, a tablet or a PC. Nothing to install, no dongle.

Gravity wall · Results
The Gravity wall module after Analyze: the drawing and the results beside it
On this page · 19 chapters
  1. 1The model of the wall
  2. 2Model at a glance
  3. 3Coordinates, free body, force ledger and sign convention
  4. 4Geometry decomposition: parts, centroids and lever arms
  5. 5The soil moving with the wall: the block behind the wall, zones, moist and saturated weight
  6. 6Effective stress and groundwater
  7. 7Rankine active and passive earth pressure
  8. 8Coulomb earth pressure on the vertical plane
  9. 9At-rest pressure and passive resistance in front of the wall
  10. 10Surcharge loads
  11. 11Hydrostatic water on both sides and uplift
  12. 12Mononobe–Okabe seismic earth pressure
  13. 13Hydrodynamic water
  14. 14Inertia of the wall and of the soil moving with it
  15. 15Sliding, overturning and bearing
  16. 16Scope of the checks
  17. 17Worked example: a wall calculated step by step
  18. 18Variables
  19. 19References
By the GeoTerva engineering teamUpdated 2026-10-1852 min readFree, no sign-up

The wall is treated as a rigid gravity block of stone masonry or plain concrete per unit length — a trapezoidal body on a stepped footing. The retained side consists of one soil layer and may include a sloping backfill, uniform surcharge and groundwater; the soil in front of the wall may add a passive resistance to the sliding check.

First slide of the lecture slides: Gravity wallPDF

Lecture slides

Ready-made slides for lectures and self-study

The mechanism, the derivation, the equations and the figures of this page, in teaching order. Every slide links back to its chapter.

38 slides · PDF · 2.2 MB

1The model of the wallWhat is analysed, and how it is drawn.

Analysis concept

Ka·(σ′v + q)Ka·(σ′v + q)δ = βδ = βPAPAββqWmWmWsoilWsoilUUPtoePtoeGWTHHDfDfBBxzOOO — origin ofx and z: the toe,base undersidex = Bx = Bretained backfillretained backfillfront soilfront soilfoundation soilfoundation soil
wall (stone masonry or plain concrete)soil that moves with the wallvirtual back plane x = Bearth + surcharge pressuregroundwater and upliftfront soil resistance
The analysis model, per 1.00 m run of wall. The free body is the wall plus the soil standing on the back footing and against the back batter; it is cut along the base underside and along the vertical virtual back plane through the back edge of the footing (x = B). The backfill pushes on that plane with the thrust PA, parallel to the ground surface (δ = β); the weights Wm and Wsoil, the uplift U under the base and the front soil resistance Ptoe complete the loads. Moments are taken about the origin O at the toe. Sections 1–4 build this figure step by step.

Rankine · static

Suitable for a conventional active/passive earth-pressure idealization. Wall friction is not explicitly used in the classical Rankine coefficient.

Ka=tan2(45°−φ′/2)Kp=tan2(45°+φ′/2)

Coulomb · static

Acts on the vertical plane through the back edge of the footing (soil against soil) with δ = β, so no wall friction is used; for this plane (α = 90°, δ = β) the Coulomb Kₐ equals the Rankine Kₐβ exactly.

Ka=f(φ′,β),α=90°,δ=β

Mononobe–Okabe · seismic

The seismic earth pressure is always the Mononobe–Okabe pseudo-static thrust: the Coulomb wedge with the inertia forces kₕ·W and ±kᵥ·W added, solved on the same pressure plane as the static case (the vertical plane at x = B, δ = β).

θ=tan−1[kh/(1±kv)]PAE=12·γ·h2·(1±kv)·KAE

Uniform surcharge

A uniform surface surcharge produces an additional lateral pressure. It is reported separately from the soil self-weight component; its vertical load over the wall is not counted as stabilising.

σq=K·q
Theory manual · how GeoTerva calculates a gravity wall

Theory manual

The overview above summarises the model. The manual below is written as a self-contained manual: every quantity that appears in the Calculations tab is explained from its physical idea, drawn, derived and then tied to the exact way the solver evaluates it. A complete numerical example (Section 16) is computed by the same engine that runs the tool, so every substitution printed there can be checked by hand.

Three theories, and no other. The tool rests on exactly three earth-pressure theories: Rankine and Coulomb for the static pressure (the user chooses one of the two), and Mononobe–Okabe for the seismic pressure. Everything else in this manual — the shape of the seismic increment, the hydrodynamic water, the inertia of the wall, the partly mobilised front resistance — is an assumption of this module and is written as such where it is used. The backfill is a granular soil: c′ = 0 throughout the tool.
How to read the manual. Every section below opens and closes on its own — click its header, or a line of the contents. Sections 1–5 build the free body (coordinates, weights, water). Sections 6–10 give the static pressures, 11–13 the seismic ones, 14 the stability checks and 15 the scope of those checks. All forces are per 1.00 m run of wall (plane strain).

2Model at a glanceGroundwater, the wall material, the stability checks and the symbols of the overview.

Groundwater & effective stress

Below the groundwater table, effective vertical stress is calculated using the submerged soil unit weight while hydrostatic water pressure is applied independently. If retained-side and front-side water levels differ, the wall experiences a net water-pressure component and the project should also consider the appropriate hydraulic stability/seepage condition.

γ′=γsat−γwu=γw·h

Wall material

Stone masonry (γm = 22 kN/m³ by default) or plain concrete (24 kN/m³); the unit weight can be changed. The wall acts by its weight: the body and the footing, and the soil standing on the back footing, hold the thrust of the backfill.

Stability checks

Sliding

FS = resisting horizontal capacity / driving horizontal force

Resistance is the base friction μb·N plus the front resistance Ptoe; no base adhesion is used.

Overturning

FS=ΣMresΣMdrv

Moments are taken about the toe — the front bottom corner of the footing.

Bearing pressure

e=B/2−xRqmax,min=NB·(1±6e/B)

The result is checked against no-tension/contact criteria and the allowable bearing pressure.

Internal stresses

The checks of this module are those of a rigid block on its foundation. The compression, tension and joint sliding inside the masonry or concrete are verified with the governing masonry or concrete code, using the actions of the Calculations tab (section 15 of the manual).

Variables

Htotal wall height (base underside → top)
Wutop width of the body
βbackfill surface inclination
δthrust inclination on the plane (δ = β)
φ′effective soil friction angle
quniform surcharge
kₕ,kᵥpseudo-static seismic coefficients
zwgroundwater depth below the wall top
wpassive state weight (1/3 default)
ηp,Eseismic passive credit factor (0)
Btotal base width

3Coordinates, free body, force ledger and sign conventionFree body, force ledger, M = x·Fz − z·Fx.

Stability is an equilibrium problem, so the first step is to decide what is in equilibrium and how forces and moments are signed. Mixing conventions (for example taking some moments "clockwise positive" and others "overturning positive") is the most common source of error in hand calculations; GeoTerva therefore uses one Cartesian system for everything.

xzO (toe)O (toe)W (Fz < 0)W (Fz < 0)x (lever arm of Fz)x (lever arm of Fz)P (Fx < 0)zzU (Fz > 0)Pₚ (Fx > 0)Pₚ (Fx > 0)M > 0 : turns the wallM > 0 : turns the wallover the toeover the toex → toward the backfillz ↑ upwardorigin: the toe, base undersideFx < 0 : pushes toward the frontFz < 0 : acts downwardM = x·Fz − z·FxM > 0 : overturningM < 0 : resistingeach part (Fx, Fz) isclassified by its own sign
Figure 2.1 Coordinate system and sign convention. The weight W, the earth thrust P, the uplift U and the front resistance Pp are drawn with their correct signs. The curved arrow shows the positive (overturning) sense of the moment about the toe.

Coordinates

The origin O is at the toe, the front bottom corner of the footing, on the base underside. x points toward the backfill and z upward. The front footing top is at z = Hfl, the back footing top at z = Hfr, the wall top at z = H, and the back edge of the footing at x = B = Wbl + Wdl + Wu + Wdr + Wbr.

Forces and the moment about the toe

A force acting on the free body is written by its components (Fx, Fz) and a point on its line of action (x, z). Its moment about O is the two-dimensional cross product r × F:

M=x·Fz−z·Fx

Why this sign is "overturning positive". A weight W at x > 0 has Fz = −W, so M = −x·W < 0: it holds the wall back. An earth thrust at height z pushing toward the front has Fx < 0, so M = −z·Fx > 0: it turns the wall over the toe. Uplift (Fz > 0) gives M > 0, front resistance (Fx > 0) gives M < 0. No force category is hard-coded as "resisting": each of the two parts x·Fz and −z·Fx is classified by its own sign. The vertical component of an inclined earth thrust, for example, is correctly counted as resisting.

The free body

The free body is the wall plus the soil that moves with it (the block behind the wall of Section 4, and the fill over the front footing). It is cut out along the base underside and along the external pressure plane. Everything that acts across those cuts, and every body force inside them, is one entry of the force ledger. The three checks read the same ledger, so a force can never be forgotten in one check and counted in another.

Ledger idForceSlidingOverturningBearing
W_CONCRETEWall self-weight, all parts (stone masonry or plain concrete; the id is the same for both)yesyesyes
W_SOIL_HEELSoil moving with the wall — over the back footing and against the back batter (γ above, γsat below the GWT)yesyesyes
Q_HEELSurcharge over the soil behind the wall — a favourable load that may be absent, always excludednonono
W_SOIL_TOEFill over the front footing — it moves with the wallyesyesyes
PA_STATIC, PA_QStatic active thrust of the soil and of the surchargeyesyesyes
PA_SPLateral pressure of the strip and point loads (rigid-wall elastic solutions), all cases at full valueyesyesyes
PAE_TOTALTotal seismic active thrust (soil + surcharge)yesyesyes
U_REAR, U_FRONTHydrostatic water on the retained and front sidesyesyesyes
UPLIFTWater pressure on the base undersideyesyesyes
HD_REAR, HD_FRONTHydrodynamic water in the seismic cases (retained and front side)yesyesyes
IH_W_…, IV_W_…Horizontal and vertical inertia of the wall, the soil behind it and the fill over the front footingyesyesyes
PP_FRONTFront soil resistance on the vertical plane at the toeyesnono
The front resistance is used in sliding only: relying on it for overturning or bearing would need the displacement that mobilises it, which those checks do not allow.

How the checks read the ledger

N=Σ(−Fz)sliding: weights − uplift ± vertical inertia + the vertical components of the earth thrust
ΣHdrive=Σ(−Fx)over every entry that is not front resistance
ΣPresist=ΣFxover PP_FRONT only
V=Σ(−Fz),ΣM=ΣMibearing: over the entries used in bearing
ΣMoverturning is the sum of the positive moment parts and ΣMresisting the sum of the absolute values of the negative parts of x·Fz and −z·Fx.

A front-side water force has Fx > 0 and therefore reduces ΣHdrive. Section 14 derives the three factors of safety from these sums.

4Geometry decomposition: parts, centroids and lever armsFront block, batters, core, back block; centroids and lever arms.

The self-weight of the wall and its moment about the toe are the backbone of both stability checks — for a gravity wall they are most of the resistance. A hand calculation splits the section into simple shapes whose area and centroid are known, computes Wi = γm·Ai for each and adds the moments Wi·x̄i. GeoTerva does exactly the same (the component table of the Calculations tab) and, as an independent check, also computes the whole outline as one polygon; the two must agree to 10⁻⁹.

xzC₁C₁x̄₁ = (Wbl + Wdl)/2x̄₁ = (Wbl + Wdl)/2C₂C₂x̄₂ = Wbl + 2Wdl/3x̄₂ = Wbl + 2Wdl/3C₃C₃x̄₃ = Wbl + Wdl + Wu/2x̄₃ = Wbl + Wdl + Wu/2C₄C₄x̄₄ = Wbl + Wdl + Wu + Wdr/3x̄₄ = Wbl + Wdl + Wu + Wdr/3C₅C₅x̄₅ = Wbl + Wdl + Wu + (Wdr + Wbr)/2x̄₅ = Wbl + Wdl + Wu + (Wdr + Wbr)/2core Wu × Hcore Wu × Hfront batterfront batterback batterback batterShape librarybbhhA = b·hx̄ = b/2 from a sidez̄ = h/2bbhhb/3b/3A = ½·b·hx̄ = b/3 from thevertical sidez̄ = h/3 above the baseAny polygon (shoelace formulas):A = ½·Σ(xᵢ·zᵢ₊₁ − xᵢ₊₁·zᵢ)x̄ = Σ(xᵢ + xᵢ₊₁)(xᵢzᵢ₊₁ − xᵢ₊₁zᵢ) / 6Az̄ = Σ(zᵢ + zᵢ₊₁)(xᵢzᵢ₊₁ − xᵢ₊₁zᵢ) / 6A
Figure 3.1 The section split into the front block (C₁: the front footing and the body above it up to Hfl), the front batter (C₂), the core under the top width (C₃, full height), the back batter (C₄) and the back block (C₅: the back footing and the body above it up to Hfr), with the lever arm of every weight measured from the toe. Right: area and centroid of the two basic shapes.

The parts

PartShape and area Ax̄ from the toez̄ from the base underside
C₁ Front blockrectangle, (Wbl + Wdl)·Hfl(Wbl + Wdl)/2Hfl/2
C₂ Front battertriangle, ½·Wdl·(H − Hfl)Wbl + 2Wdl/3Hfl + (H − Hfl)/3
C₃ Corerectangle, Wu·HWbl + Wdl + Wu/2H/2
C₄ Back battertriangle, ½·Wdr·(H − Hfr)Wbl + Wdl + Wu + Wdr/3Hfr + (H − Hfr)/3
C₅ Back blockrectangle, (Wdr + Wbr)·HfrWbl + Wdl + Wu + (Wdr + Wbr)/2Hfr/2
Each batter triangle has its vertical side against the core and its apex at the wall top, so its centroid lies one third of the batter offset from the core and one third of its height above the footing top. With Wdl = 0 or Wdr = 0 the batter vanishes and that face of the body is vertical.

Weights and moments

Wi=γm·Ai
Mi=Wi·x¯i
Wm=ΣWi
x¯m=ΣWi·x¯iΣWi

In the ledger the wall is one entry W_CONCRETE with Fz = −Wm at (x̄m, z̄m), so its moment is M = −Wm·x̄m = −ΣMi. The height z̄m is needed only for the horizontal inertia kh·Wm of Section 13. γm is the unit weight of the wall material: 22 kN/m³ for stone masonry and 24 kN/m³ for plain concrete by default (the value can be changed; a dry-stone wall with open joints is lighter).

Hand-check tip. Sum the areas first and compare with the gross outline: A = (Wbl + Wdl)·Hfl + ½·Wdl·(H − Hfl) + Wu·H + ½·Wdr·(H − Hfr) + (Wdr + Wbr)·Hfr. For the default wall (H = 3.00 m, Wu = 1.00 m, every other dimension 0.50 m): 0.500 + 0.625 + 3.000 + 0.625 + 0.500 = 5.250 m², Wm = 22 × 5.250 = 115.50 kN/m at x̄ = 1.500 m (the section is symmetric).

5The soil moving with the wall: the block behind the wall, zones, moist and saturated weightThe soil block behind the wall, pressure plane, moist and saturated zones.

Why does the earth pressure not act simply on the back batter of the wall? Because the soil standing on the back footing cannot slide relative to it: when the wall moves, that soil moves with it. In the limiting state the backfill behind it reaches failure along planes that start at the back edge of the footing, not on the batter. The mechanically consistent free body is therefore the wall plus this soil block, loaded by the earth pressure on its outer face — the external pressure plane (often called the virtual back).

Vertical plane through the back edge of the footing (all methods)γγsatS_SLOPES_SLOPEstress parallel to thestress parallel to theground (angle β)ground (angle β)GWTx = Bx = B
Figure 4.1 The external pressure plane: the vertical plane through the back edge of the footing, used by Rankine, Coulomb and Mononobe–Okabe. The plane is soil against soil, so the thrust on it is parallel to the ground (δ = β); no wall friction is used. The shaded soil — over the back footing, against the back batter and above wall-top level on a rising slope — moves with the wall and is split at the GWT into moist and saturated zones.

The plane runs from the ground surface above the back edge (x = B, z = zground(B)) down to the base underside. On a sloping backfill it therefore includes the rise of the ground over the block. Above the back footing top (z = Hfr) it is the virtual soil–soil plane; over the footing height (z = 0 … Hfr) it is the end face of the back footing, and the same pressure is applied down to the base underside, as in the standard hand calculation (the source, Bowles). Everything between the plane and the back of the wall is weight. A wall with Wdr = Wbr = 0 has a vertical back face at x = B and no soil block; the plane is then the back of the wall itself, still with δ = β — no wall friction is credited.

The seismic case uses the same plane: the Mononobe–Okabe wedge is solved on the vertical plane at x = B with δ = β; its height is h = zground(B) = H + the rise of the slope over the back of the wall.

Zones

For the component table the soil is clipped into named zones, each split at the water table into a moist part (unit weight γ) and a saturated part (γsat):

Zone idRegion
S_HEELSoil behind the wall: over the back footing and against the back batter, from the back footing top to wall-top level
S_SLOPEThe wedge of sloping ground above wall-top level
S_TOEFill over the front footing: from the front footing top to the front ground, when Df > Hfl
Wsoil=γ·Amoist+γsat·Asat
x¯soil=ΣWj·x¯jΣWj

Why γsat and not γ′ below the water table? The free body is written in total stress: the soil is weighed with its pore water, and the water pressure on the boundary of the free body (U_REAR on the pressure plane, UPLIFT on the base underside) is applied as separate forces. By Archimedes, total weight minus the resultant of the boundary water pressure equals the effective (buoyant) weight, so the two descriptions are identical — but mixing them (γ′ and uplift) would count buoyancy twice.

Excluded vertical load. The surcharge over the soil behind the wall (Q_HEEL) is a favourable vertical load that may be absent when the lateral load acts: it is listed in the ledger as excluded and enters no check, while it still pushes on the plane. The fill over the front footing (W_SOIL_TOE) is different: it rests on the footing and moves with the wall, so its weight is a vertical load — in N, in the resisting moment and in the bearing resultant — and the front soil still provides the passive resistance of Section 8. Enter Df = 0 when the front soil may be removed.

6Effective stress and groundwaterσ′v, pore pressure, γ′ and the porosity of the backfill.

Soil strength and therefore earth pressure are governed by the effective stress — the part of the total stress carried by the grain skeleton. Water has no shear strength: it pushes equally in every direction and is added to the lateral pressure with a coefficient of one. Every lateral pressure in GeoTerva is therefore built in two separate layers: K·σ′v from the soil and u from the water.

GWTγγsatd₁d₁depthσv (total)γ·d₁γ·d₁γ·d₁ + γsat·d₂γ·d₁ + γsat·d₂−u (pore water)γw·d₂γw·d₂=σ′v (effective)γ·d₁γ·d₁γ·d₁ + γ′·d₂γ·d₁ + γ′·d₂pₕ = K·σ′v + uK·σ′vu
Figure 5.1 Vertical stresses in a backfill with a water table at depth d₁. The total stress minus the pore pressure gives the effective stress; the lateral pressure on the wall is the earth-pressure coefficient times the effective stress plus the full pore pressure.

Governing equations

σv=γ·ddry+γsat·dsub
u=γw·dsub
σ′v=σv−u=γ·ddry+γ′·dsub(+q)
γ′=γsat−γw

ddry is the depth above the water table and dsub the depth below it, both measured from the top of the pressure plane, the ground surface above the back edge of the footing. A uniform surcharge adds q to σ′v at every depth.

Porosity of the backfill

The seismic pore-water assumption (Section 12) needs the dry (skeleton) unit weight, which is not an input. It follows from the phase relations with the specific gravity of the solids, Gs = 2.65 — an internal constant of the module, not an input. With void ratio e, γsat = (Gs + e)·γw/(1 + e); with porosity n = e/(1 + e) this becomes γsat = [Gs(1 − n) + n]·γw, and solving for n:

n=Gs·γw−γsat(Gs−1)·γw
γd=Gs(1−n)·γw=γsat−n·γw
(a) Phases of the saturated backfill (Gs = 2.65)watersolidsnn1 − n1 − nn·γw= 3.63 kNγd = Gs(1 − n)γw= 16.37 kNvolume 1 m³ → weight γsat = 20.00 kN(b) The three unit weights (kN/m³)γsat20.00γd16.37γ′10.19γd > γ′ : buoyancy reduces the weight ofthe grains, not their mass.
Figure 5.2 The phase relations for the values the solver prints: γsat = 20 kN/m³, γw = 9.81 kN/m³ and Gs = 2.65 give n = 0.370, γd = 16.37 kN/m³ and γ′ = 10.19 kN/m³. The dry unit weight carries the seismic inertia of the grains (Section 12), the submerged one their weight.

For γsat = 20 kN/m³, γw = 9.81 kN/m³ and Gs = 2.65: n = (2.65·9.81 − 20)/(1.65·9.81) = (25.9965 − 20)/16.1865 = 0.370 and γd = 20 − 0.370·9.81 = 16.37 kN/m³ — the values the solver prints in its assumption note. Note γd > γ′ = 10.19 kN/m³: buoyancy reduces the weight of the grains, not their mass.

Assumptions. The water pressure is hydrostatic on both sides (no seepage flow). If the backfill is drained, switch the retained water off; a steady seepage toward a drain changes both the pore pressure and the effective stress and is not modelled. Different water levels on the two sides imply seepage under the wall — check piping and heave at the toe separately.

7Rankine active and passive earth pressureActive and passive states, sloping backfill.

Imagine a soil element at depth z behind the wall before anything moves. The vertical effective stress is σ′v and the horizontal one is K0·σ′v (Section 8). If the wall moves away from the soil, the horizontal stress falls while the vertical stress stays the same; the Mohr circle grows to the left until it touches the failure envelope. That limiting horizontal stress is the active pressure. If the wall is pushed into the soil the horizontal stress rises past σ′v until the circle touches the envelope on the right: the passive pressure. The active state needs only a small outward movement (in the order of a few tenths of a percent of the height for granular soil); full passive resistance needs a movement roughly an order of magnitude larger.

σ′ττ = σ′·tan φ′τ = σ′·tan φ′σ′vσ′aσ′h0σ′pactiveactivepassivepassiveat restActive: σ′v is the major principalstress, σ′h falls to σ′a;slip planes at 45° + φ′/2.Passive: σ′v is the minor principalstress, σ′h rises to σ′p;slip planes at 45° − φ′/2.
Figure 6.1 Mohr circles for φ′ = 30° and σ′v = 100 kPa: at rest (σ′h = 50 kPa), active (σ′a = 33.3 kPa, Ka = 1/3) and passive (σ′p = 300 kPa, Kp = 3). Both limiting circles touch the Mohr–Coulomb envelope τ = σ′·tan φ′.

Derivation from the Mohr–Coulomb criterion

For a circle touching the envelope τ = σ′·tan φ′ (a line through the origin for a granular soil) the radius equals sin φ′ times the distance of the centre from the origin:

σ′1−σ′32=sinφ′·σ′1+σ′32
⇒σ′1(1−sinφ′)=σ′3(1+sinφ′)
⇒σ′1=σ′3·tan2(45°+φ′/2)

using (1 + sin φ′)/(1 − sin φ′) = tan²(45° + φ′/2). In the active state σ′1 = σ′v and σ′3 = σ′a; in the passive state σ′3 = σ′v and σ′1 = σ′p:

σ′a=Ka·σ′v
σ′p=Kp·σ′v
Ka=tan2(45°−φ′/2)=1−sinφ′1+sinφ′
Kp=tan2(45°+φ′/2)=1/Ka

For a dry, uniform backfill of height h the pressure is a triangle, so the thrust and its height above the bottom are Pa = ½·Ka·γ·h² and h/3. Water and a surcharge change σ′v (Sections 5 and 9), not the coefficient.

Sloping backfill

For a ground surface inclined at β, Rankine's argument for a semi-infinite slope shows that the stress on a vertical plane is parallel to the surface. Its magnitude is σ′a = Kaβ·σ′v with

Kaβ=cosβ·cosβ−cos2β−cos2φ′cosβ+cos2β−cos2φ′
(a) Active state behind a vertical face45° + φ′/245° + φ′/2Pa = ½Kaγh²Pa = ½Kaγh²h/3h/3hhKa·γ·h(b) Kaβ against the backfill slopeβ (°)Kaβ0102030400.30.60.9φ′ = 30°φ′ = 30°φ′ = 35°φ′ = 35°β = 0 : Ka = 1/3β = 0 : Ka = 1/3β < φ′ required
Figure 6.2 (a) The active state behind a vertical face: the soil fails along planes at 45° + φ′/2, the pressure grows linearly to Ka·γ·h and the thrust ½·Ka·γ·h² acts at h/3 above the bottom. (b) The coefficient for a sloping backfill, drawn from the formula above for φ′ = 30° and 35°: Kaβ rises with the slope and reaches cos φ′ when β = φ′, where the slope itself is at its limit of stability.
Sloping ground: the stress on the vertical plane is parallel to the surfaceβσ′ₐ = Kₐβ·σ′vσ′ₐ = Kₐβ·σ′vhorizontal: σ′ₐ·cos βhorizontal: σ′ₐ·cos βvertical: σ′ₐ·sin β (down)vertical: σ′ₐ·sin β (down)soil block side(moves with the wall)vertical plane at x = B
Figure 6.3 Under a sloping ground the Rankine stress on the vertical plane through the back edge of the footing acts parallel to the ground surface; its vertical component is a downward (stabilising) force on the free body.

The horizontal component on the plane is Kaβ·cos β·σ′v and the vertical component Kaβ·sin β·σ′v, downward for a rising slope. For β = 0 the expression reduces to Ka. The square root requires β < φ′; for β ≥ φ′ the slope itself is not stable and the calculation is blocked.

Implementation

01
σ′v(z)

Built from the real ground surface above the point — γ above and γ′ below the GWT — plus q (Section 5).

02
Stress on the plane

σ′a = Kaβ·σ′v, split into its horizontal part Kaβ·cos β·σ′v and its vertical part Kaβ·sin β·σ′v.

03
Integration

Composite Simpson rule along the plane, split at the GWT and the back footing top, so no panel straddles a kink.

04
Ledger

PA_STATIC (soil) and PA_Q (with q minus without q), each with its resultant height z = −Mx/Fx.

Front passive resistance uses the Rankine Kp for a horizontal front ground and a smooth face (no wall friction, which is conservative for passive resistance); see Section 8 for the passive state blend with K0.

Limits of Rankine. The solution assumes a semi-infinite soil mass in a uniform limit state and a plane without shear other than that implied by the slope. On the vertical plane through the back edge of the footing the soil–soil interface makes this realistic, which is why it is the standard design model for walls with a block of soil moving with them. Rankine and Coulomb both use this same vertical plane at x = B; there is no alternative inclined back.

8Coulomb earth pressure on the vertical planeTrial wedge, closed form, on the vertical plane with δ = β.

Coulomb (1776) did not look at stresses at all. He took a rigid wedge of soil bounded by the wall back, the ground surface and a trial plane from the wall bottom, and asked what force the wall must supply to keep that wedge in limiting equilibrium. Three forces act on the wedge: its weight W (known), the reaction R of the soil below the trial plane, inclined at φ′ to the plane normal because the wedge is about to slide down, and the wall reaction P, inclined at the wall friction angle δ to the wall normal. The directions of R and P are known, so the force triangle can be closed.

WWPPRRραδδφ′φ′βABCtrial failure planetrial failure planeForce polygon (closes for equilibrium)WPRP(ρ) is found for every trial ρ;the active thrust is the maximum.
Figure 7.1 Coulomb trial wedge ABC for a failure plane at ρ from the horizontal and its force polygon. P and R make the angles δ and φ′ with the normals of the wall back and the failure plane; α is the angle of the back measured from the horizontal on the wall side.

Derivation for a vertical wall and horizontal ground

With a vertical back (α = 90°) and β = 0, the wedge weight is W = ½·γ·H²·cot ρ. Applying the sine rule to the force triangle (the angle between W and R is ρ − φ′, the angle opposite W is 90° + δ − (ρ − φ′)):

P(ρ)=W·sin(ρ−φ′)cos(ρ−φ′−δ)=12·γ·H2·cotρ·sin(ρ−φ′)cos(ρ−φ′−δ)

The wall must resist the most dangerous wedge, so Pa = max over ρ of P(ρ), from dP/dρ = 0. For δ = 0 this gives ρ = 45° + φ′/2 and Pa = ½·γ·H²·tan²(45° − φ′/2): Coulomb and Rankine coincide.

P(ρ) for γ = 18 kN/m³, H = 5.00 m, φ′ = 30°, δ = 0 — the active thrust is the maximumtrial plane angle ρ (°)P(ρ) (kN/m)30405060708090306090Pa = ½·Ka·γ·H² = 75.0 kN/mPa = ½·Ka·γ·H² = 75.0 kN/mρcr = 45° + φ′/2 = 60°ρcr = 45° + φ′/2 = 60°flat plane:heavy wedge,almost self-supportingsteep plane:light wedge
Figure 7.2 The same function drawn for γ = 18 kN/m³, H = 5.00 m, φ′ = 30° and δ = 0. A flat plane (ρ → φ′) gives a heavy wedge that is almost self-supporting and a steep one (ρ → 90°) a very light wedge; between them the thrust the wall must supply is largest, here at ρ = 60° = 45° + φ′/2 with Pa = 75.0 kN/m — exactly ½·Ka·γ·H² with Ka = 1/3. The static case uses the closed form below; under the earthquake the solver maximises the same function numerically with the inertia forces added (Section 11).

General closed form

Ka=sin2(α+φ′)sin2α·sin(α−δ)·[1+sin(φ′+δ)·sin(φ′−β)sin(α−δ)·sin(α+β)]2
Pa=12·γ·h2·Kaacting at δ to the normal of the back, h/3 above its bottom

The resultant has a horizontal and a vertical component; the vertical one acts downward on the free body and adds to N and to the restoring moment. GeoTerva distributes the thrust as p = Ka·σ′v along the plane, with σ′v built from the ground surface above the back edge of the footing (γ above and γ′ below the groundwater table).

The plane used by GeoTerva. The Coulomb back is the vertical plane through the back edge of the footing (x = B, α = 90°), the same plane as Rankine. That plane is soil against soil, so the real wall friction does not act on it; the thrust is taken parallel to the backfill surface, δ = β. For this plane (α = 90°, δ = β) the Coulomb Ka equals the Rankine Kaβ exactly, for every β, so the two methods give the same pressure on it.

Limits. Coulomb requires β ≤ φ′ (δ = β here). The planar failure surface is accurate for active pressure; it overestimates passive resistance for large δ, which is why front resistance uses the Rankine Kp without wall friction.

9At-rest pressure and passive resistance in front of the wallRankine Kp, Jaky K0, the blend Kmob = w·Kp + (1 − w)·K0, hignore, toe passive.

The at-rest state is the stress state of soil that has not been allowed to strain laterally; for a normally consolidated granular soil K0 = 1 − sin φ′. On the retained side GeoTerva always uses the active state (a gravity wall on a soil foundation slides and rotates enough to reach it). On the front side K0 is the lower end of the passive state blend below.

Passive pressure

The soil in front of the wall is described by a blend of the Rankine passive and the Jaky at-rest coefficients with c′ = 0 and the geostatic effective vertical stress (γ′ below the front water level). The front ground lies at Df above the base underside — Df is the input of the Model tab. The top layer hignore may be excavated, softened or disturbed during the life of the wall, so the depth is measured from the lowered ground:

Kp=tan2(45°+φ′/2)
K0=1−sinφ′Jaky, for a normally consolidated granular soil
Kmob=w·Kp+(1−w)·K0w = 1 (Full Passive), 2/3, 1/3 (default), 0 (Full Rest)
p(z)=Kmob·σ′v(z)z = depth below the front ground lowered by hignore
Kmob = w·Kp + (1 − w)·K0 (φ′ = 30°: K0 = 0.50, Kp = 3.00)0.50Full Rest1.331/3 Passive (default)2.172/3 Passive3.00Full PassivePressure on the front of the wall, Df = 1.20 m, hignore = 0.20 m, γ = 18 kN/m³ (dry)front groundlowered by hignorebase undersidew = 09.0 kPaw = 1/324.0 kPaw = 2/339.0 kPaw = 154.0 kPaztop = 1.00ztop = 1.00
Figure 8.2 Top: the four passive states of the tool are the four points of the blend Kmob = w·Kp + (1 − w)·K0 between the at-rest and the full passive coefficient. Bottom: the pressure each of them gives on the front of the wall in a dry front soil — the top layer hignore is not relied upon, so the depth is measured from the lowered ground and the diagram is a triangle over ztop = Df − hignore. The default 1/3 Passive gives 44 % of the full passive resistance.
PtoePtoeDfDfx = 0 (toe)x = 0 (toe)fill over the front footingfill over the front footing
Figure 8.1 The passive triangle on the vertical plane at the toe (x = 0), from the front ground down to the base underside. It pushes toward the backfill (Fx > 0). When Df > Hfl the soil above the front footing rests on it and moves with the wall (Section 4).

Toe passive resistance (optional, default on)

ztop=max(Df−hignore,0)
Ptoe=∫0ztopKmob·σ′vdzσ′v: γ above and γ′ below the front water level; for a uniform dry soil it is ½·Kmob·γ·ztop², acting ztop/3 above the base underside
credit=Ptoethe whole blended resistance is credited

Full passive resistance needs a displacement far larger than a serviceable wall should have, so the coefficient is interpolated between the at-rest state (no movement, w = 0) and the full Rankine passive state (w = 1); the whole blended resistance is credited. The toe passive can be switched off; the weight of the fill over the front footing is always a vertical load (Section 4).

Used in sliding only

FSs=μb·Neff+PtoeHdrive

PP_FRONT enters the sliding resistance only. It is not used in the overturning moment or the bearing resultant.

Seismic cases

creditE=ηp,E·Ptoe

No seismic passive coefficient is used. A single factor ηp,E (default 0 = no passive credit) multiplies the static blended resistance.

10Surcharge loadsUniform q, its lateral pressure and its vertical load.

A uniform load q spread over the whole backfill surface raises the vertical stress by q at every depth (an infinitely wide load spreads without decay). The lateral pressure therefore gains a constant K·q in the simple case, and the thrust gains K·q·h acting at mid-height of the plane.

Δσ′v=q
Δph=Ka·q
Pq=Ka·q·h
zq=h/2above the bottom of the pressure plane
Rectangle K·q plus triangle K·γ·zqPq = K·q·hat h/2P = ½K·γ·h² at h/3K·qK·γ·h
Figure 9.1 The rectangle K·q adds to the soil triangle; the surcharge thrust acts at mid-height of the plane, the soil thrust at one third.

How GeoTerva separates it. The thrust is computed twice on the same plane, with q and without q; PA_Q is the difference. This definition stays exact under a sloping ground.

Vertical effect. The surcharge over the soil behind the wall (Q_HEEL = q × the horizontal length of ground over that block) is a favourable vertical load and is excluded from every check — an assumption of this module. Its lateral effect is always kept: a load that pushes on the wall when present must be assumed present.

Seismic cases. In the Mononobe–Okabe wedge the surcharge on the wedge top is a force Q with its own inertia kh·Q and (1 ± kv)·Q (Section 11).

Strip and point loads

A strip load q between the distances x1 and x2 from the wall and a point load Q at the distance x press on the wall through the soil, and their effect decays with depth. GeoTerva takes their lateral pressure by the elastic solutions for a rigid wall — the same as the sheet-pile modules and the Surcharge Loads tools: the Boussinesq stress doubled by the wall (the image method). z is the depth below the ground at the top of the wall and x the horizontal distance from the back face of the wall at its top.

ps(z)=2qπ(β−sinβcos2α)strip load, β = atan(x₂/z) − atan(x₁/z), α = atan(x₁/z) + β/2
ps(z)=3Qx2zπR5point load, R² = x² + z², on the section of wall through the load
Fs=2qπD[arctanx2D−arctanx1D]resultant of a strip load over the depth D
Fs=Qπx[1−x3(x2+D2)3/2]resultant of a point load over the depth D

Where it acts. The pressure is carried from the ground at the top of the wall down to the bottom of the pressure plane (D = the height of the plane below the wall top), on the stem back face for the structural actions and on the pressure plane for the stability, and it is added to the soil pressure at its full value in the static and in the seismic cases (no combination factor: the loads are taken as present, as the uniform surcharge is). Its resultant is the ledger entry PA_SP: a horizontal force toward the front at the depth where its moment is balanced, closed forms of the integrals above.

Assumptions. A point load nearer than 0.30 m is taken at 0.30 m (the elastic solution is singular at the wall). The pressure of a point load is that on the section of wall through the load — the most loaded metre of wall — and is used for the whole wall, on the safe side. The loads are taken on the ground at the level of the top of the wall, also where the backfill slopes. Only the lateral pressure is taken: the weight of the loads on the soil over the heel is not (a favourable vertical load that may be absent, excluded as the uniform surcharge over the heel is).

11Hydrostatic water on both sides and upliftWater on both sides, linear uplift under the base.

Water pressure is isotropic and acts normal to every surface it touches. The free body of Section 4 is surrounded by water on three of its boundaries: the pressure plane on the retained side, the front of the wall, and the base underside. Each is one ledger entry.

retained water zwfront waterγw·hwγw·hwfutoe = γw·hwfutoe = γw·hwfuheel = γw·zw,rearuheel = γw·zw,rearhw = zw,rearhw = zw,rearhwfhwfU = B·(utoe + uheel)/2 at x = B·(utoe + 2uheel) / (3(utoe + uheel))U = B·(utoe + uheel)/2 at x = B·(utoe + 2uheel) / (3(utoe + uheel))
Figure 10.1 Hydrostatic pressure on the retained side (on the pressure plane), on the front of the wall and under the base. The uplift varies linearly between the heads at the toe and at the back edge of the base (the heel).

Retained side, U_REAR

u(z)=γw·(zw,rear−z)
Pw=12·γw·hw2
zPw=hw/3
hw=zw,rear=H−zw

zw,rear = H − zw is the elevation of the retained water table above the base underside (zw = the groundwater depth below the wall top, the input); the column stands on the base underside, so hw = zw,rear and Pw acts hw/3 above it. If a falling slope puts the water table above the ground at the plane top, only the part of the column below the plane top loads the plane: Pw = ½·γw·(hw² − h0²), a trapezoid.

Front side, U_FRONT

The front water height hwf is entered above the base underside; the water acts on the front of the wall down to the base underside, so Pwf = ½·γw·hwf² at hwf/3. It pushes toward the backfill (Fx > 0) and reduces the net driving force.

Uplift, UPLIFT

The pore pressure under the base is taken to vary linearly from the head at the toe to the head at the back edge of the base (straight-line head loss along the base):

utoe=γw·hwf0 without front water
uheel=γw·zw,rear0 without retained water
U=B·utoe+uheel2
xU=B·(utoe+2uheel)3(utoe+uheel)
Trapezoid = rectangle + triangleutoeutoeuheeluheelrectangle utoe·Btriangle ½(uheel − utoe)·Btriangle ½(uheel − utoe)·BB/2B/22B/32B/3U upward at xU
Figure 10.2 The uplift trapezoid split the way the hand calculation does it: a rectangle utoe·B whose resultant is at B/2 and a triangle ½(uheel − utoe)·B whose resultant is at 2B/3 from the toe. Taking moments about the toe gives U·xU = B²(utoe + 2uheel)/6, hence the formula above.

Derivation of xU. Split the trapezoid into a rectangle utoe·B at B/2 and a triangle ½·(uheel − utoe)·B at 2B/3 from the toe. Taking moments: U·xU = utoe·B²/2 + (uheel − utoe)·B²/3 = B²(utoe + 2uheel)/6, and dividing by U gives the formula. Uplift acts upward (Fz = +U), so it reduces N — and with it the base friction — and adds an overturning moment U·xU.

Assumptions. The head field is a straight line in x between the two heads, which ignores any drainage under the base. Switch uplift off only when the water table lies below the base underside or a drainage layer prevents pressure under the base. The weight of the soil behind the wall uses γsat below the water table precisely because the uplift and U_REAR are applied (Section 4). A masonry wall with open joints may also carry pore pressure inside its body; that is not modelled — the wall is treated as impervious.

12Mononobe–Okabe seismic earth pressureθ, the active wedge, the seismic passive credit ηp,E, where the increment acts.

An earthquake shakes the wall and the backfill back and forth. The pseudo-static method replaces this transient loading by constant body forces: every mass m receives a horizontal force kh·m·g and a vertical force ±kv·m·g, where kh and kv are the seismic coefficients (fractions of g). For the wall the critical horizontal direction is the one in which the inertia forces push toward the front — the same direction as the earth pressure. The vertical coefficient is uncertain in sign, so GeoTerva runs both: weights multiplied by (1 − kv) and by (1 + kv).

θ=tan−1kh1±kv
gθ=g·(1±kv)2+kh2
(a) Weight + inertia = gravity rotated by θdrawn for kh = 0.30, kv = 0(1 ± kv)·W(1 ± kv)·Wkh·Wkh·WW·√((1 ± kv)² + kh²)θθ(b) KAE against kh (φ′ = 30°)khKAE0.00.20.40.60.51.0Ka = 0.333kh = 0.15 : 0.433kh = tan φ′ :no wedge in equilibrium
Figure 11.1 (a) The weight and the inertia of every mass add up to one force of magnitude W·√((1 ± kv)² + kh²) inclined at θ to the vertical: the earthquake is replaced by a gravity field rotated by θ. (b) What that does to the active coefficient of a vertical plane with a horizontal backfill: KAE grows from Ka = 1/3 and runs away as kh approaches tan φ′, where the rotated gravity is steeper than the friction angle can carry and no wedge is in equilibrium.

Gravity and inertia together act like a gravity field rotated by θ from the vertical. Coulomb's wedge is therefore solved for the seismic case by adding the inertia forces to the force polygon — this is the Mononobe–Okabe method, the only seismic earth-pressure theory used by the tool.

(1 ± kᵥ)·W(1 ± kᵥ)·Wkₕ·Wkₕ·WθPPRRρForce polygon with inertia(1 ± kᵥ)WkₕWPRθThe resultant of weight and inertia isW·√((1 ± kᵥ)² + kₕ²) at θ to the vertical.
Figure 11.2 Trial wedge with pseudo-static forces. Adding kh·W to the force polygon tilts the effective weight by θ; the wall must supply a larger P to close the polygon, and the critical failure plane becomes flatter (smaller ρ).

11.1 Mononobe–Okabe active thrust

Okabe (1926) and Mononobe and Matsuo (1929) applied Coulomb's wedge with the inertia forces added. Maximising P over ρ gives the closed form (ψ = inclination of the back from the vertical, δ = thrust inclination — δ = β on the vertical plane through the back edge of the footing, β = backfill slope):

KAE=cos2(φ′−θ−ψ)cosθ·cos2ψ·cos(δ+ψ+θ)·[1+sin(φ′+δ)·sin(φ′−θ−β)cos(δ+ψ+θ)·cos(β−ψ)]2
PAE=12·γ·h2·(1±kv)·KAE

For θ = 0 it reduces to Coulomb's Ka. The square root needs φ′ − θ − β ≥ 0: when the rotated gravity is steeper than the friction angle allows, no wedge can be in equilibrium: the thrust keeps growing as the failure plane approaches the backfill surface, the load case is reported with “no solution” and its checks count as not satisfied. GeoTerva solves the same wedge numerically on the case's pressure plane: the forces on the wedge are its weight W, the surcharge Q on its top, the horizontal inertia (W + Q)·kh, the vertical force (W + Q)(1 ± kv), the reaction R at φ′ to the failure plane and the thrust P at δ to the plane normal; the wedge is clipped at the GWT (γ above, γ′ below for the weight, Section 12 for the inertia), so a submerged backfill and a surcharge can be included. For a dry, uniform wedge the closed form is reproduced exactly (tested). The static reference PA of a seismic case is the static-case thrust on the same plane (the Rankine or Coulomb closed form of Sections 6–7, soil + surcharge), so ΔPAE = PAE − PA,static. The wedge with kh = kv = 0 can differ slightly from it (for example with a water table under a sloping backfill); it is shown for information only. For every method the plane is the vertical plane through the back edge of the footing (x = B) and the thrust is inclined at δ = β (soil against soil, no wall-friction input).

11.2 Passive resistance under the earthquake

No seismic passive coefficient is used. The front soil accelerates with the ground and its resistance is uncertain, so the passive credit of a seismic case is the static blended resistance in front of the wall (Section 8) multiplied by a single factor ηp,E. The default ηp,E = 0 gives no passive credit; a value above zero is a project acceptance. Base friction uses Neff of each seismic case.

creditE=ηp,E·Ptoeηp,E = 0 by default: no passive credit under the earthquake

11.3 Where the seismic increment acts — an assumption of this module

The wedge gives the magnitude of PAE but not its distribution. Model tests show that the seismic increment acts higher than the static thrust. GeoTerva takes the increment ΔPAE = PAE − PA (PAE from the wedge, PA the static-case thrust on the same plane, Section 11.1) and assumes for it an inverted trapezoid over the plane height he, 1.6·ΔP/he at the top and 0.4·ΔP/he at the bottom, with u the height above the plane bottom; the static part keeps its static shape:

Δp(u)=ΔPAEhe·(0.4+1.2·uhe)
∫0heΔpdu=ΔPAE·(0.4+0.6)=ΔPAE
∫0heu·Δpdu=ΔPAE·he·(0.2+0.4)=0.6·he·ΔPAE
zAE=PA·zA+ΔPAE·0.6hePAE
(a) static PA — triangle, resultant h/3PAh/3h/3(b) ΔPAE — inverted trapezoidΔPAE0.6·hₑ0.6·hₑ1.6·ΔP/hₑ0.4·ΔP/hₑ(c) total pAE = pA + ΔpPAE
Figure 11.3 (a) The static part keeps its own shape. (b) The increment is an inverted trapezoid, 1.6·ΔP/he at the top and 0.4·ΔP/he at the bottom, with its resultant at 0.6·he. (c) The total pressure used for the resultant height of PAE.

A non-positive increment keeps the static shape (the static distribution is then scaled to PAE).

Limits. Pseudo-static coefficients are not peak accelerations: kh is commonly taken as a fraction of PGA/g depending on the allowable displacement, as specified by the governing code. The method assumes a rigid-plastic backfill and gives no displacement. Near θ → φ′ − β the thrust grows very quickly and the result becomes sensitive to small input changes.

13Hydrodynamic waterThe parabolic pressure on the water columns; free pore water in the backfill.

When a wall accelerates against free water, the water cannot follow instantly and an additional pressure develops. GeoTerva assumes the classical parabolic pressure for a rigid vertical face and incompressible water and applies it to the vertical projection of the water column on the retained side (HD_REAR) and to the front water (HD_FRONT). It is always included in the seismic cases when water is present — there is no switch; it enters the stability ledger.

phd(y)=78·kh·γw·hw·y
Phd=712·kh·γw·hw2
zhd=0.4·hwabove the bottom of the water column
y is the depth below the water surface and hw the height of the water column.
(a) Hydrodynamic pressure on a vertical facewater surfacePhd0.4·hw0.4·hwhwhw7/8·kₕ·γw·hwdashed: hydrostatic shape(b) Pore water in the backfill (assumption)free pore water (permeable backfill)the water moves through the pores:inertia on the skeleton γd = γsat − n·γw, weight on γ′,plus the hydrodynamic pressure on the water column
Figure 12.1 (a) The parabolic hydrodynamic pressure and its resultant at 0.4·hw. (b) The pore water of the submerged backfill is assumed free: the horizontal inertia of the active wedge acts on the soil skeleton and the water adds the hydrodynamic pressure.

Derivation of the resultant and its height

Phd=∫0hw78khγwhw·y1/2dy=78khγwhw·23hw3/2=712khγwhw2
Mbottom=∫0hwp(y)·(hw−y)dy=78khγwhw3·(23−25)=730khγwhw3
zhd=MbottomPhd=7/307/12·hw=0.4·hw

The column runs from the water table to the bottom of the pressure plane. If the water table is above the ground at the plane top (h0 of water above it), only the part below the plane top is applied: P = 7/12·kh·γw·√hw·(hw1.5 − h01.5). On the front face the wall moves away from the water during the critical half-cycle, so the pressure drops; the drop acts toward the front, in the same direction as the rear increase.

Pore water under earthquake: free — an assumption of this module

Below the water table the backfill contains water. The module assumes it is free, able to move relative to the grains: the soil skeleton carries the inertia of the grains only, γd = γsat − n·γw (the porosity n from Section 5), while the weight stays on γ′, and the free water adds the hydrodynamic pressure above. In the wedge the horizontal inertia below the water table is therefore kh·γd·Asub with weight γ′·Asub. Some formulations reduce the hydrodynamic pressure by the porosity; GeoTerva keeps the full γw, which is conservative.

The soil moving with the wall is different. The pore water inside the soil block behind the wall is enclosed by the wall and the footing and must move with it, so the horizontal inertia of that block uses its total mass (γ above, γsat below the water table). Buoyancy reduces weight, never mass: the horizontal inertia never uses γ′ (active wedge γd, soil block γsat); the vertical force of the wedge is (1 ± kv)·γ′·A.

14Inertia of the wall and of the soil moving with itkh·W and kv·W at the centroids.

The Mononobe–Okabe wedge of Section 11 describes the soil behind the pressure plane. The free body itself — the wall and the soil block behind it — has mass too, and in the pseudo-static model it receives the same body forces. For a gravity wall they are large: the whole resistance comes from weight, so the same weight, multiplied by kh, pushes the wall toward the front at the height of its centroid.

kₕ·WC₁kₕ·WC₁kₕ·WC₂kₕ·WC₂kₕ·WC₃kₕ·WC₃kₕ·WC₄kₕ·WC₄kₕ·WC₅kₕ·WC₅kₕ·Wsoilkₕ·WsoilIH_W_CONCRETE: Fx = −kₕ·Wmat the wall centroid (x̄m, z̄m)IH_W_SOIL_HEEL: Fx = −kₕ·WsoilIV_…: Fz = ∓kᵥ·W (same point)M = −z̄·Fx + x̄·Fzdashed: vertical inertia ±kᵥ·W
Figure 13.1 Pseudo-static inertia forces at the centroids of the wall parts and of the soil behind the wall. The horizontal forces (solid) act toward the front; the vertical ones (dashed) act upward in the "kv up" case and downward in the "kv down" case.
Fx=−kh·Whapplied at the centroid (x̄, z̄) of the part
Fz=∓kv·W
MH=kh·Wh·z¯overturning
MV=±kv·W·x¯

Wh is the mass-carrying weight: for the wall Wm; for the soil block and the fill over the front footing γ·Amoist + γsat·Asat (Section 12). In the ledger the wall, the soil behind it and the fill over the front footing are one entry each (IH_W_CONCRETE, IH_W_SOIL_HEEL, IH_W_SOIL_TOE, and IV_… when kv > 0). The Calculations tab also lists the inertia of every wall part and soil zone; their sum equals the ledger entries, which is the hand check.

Why the heights matter. The horizontal inertia enters the overturning moment with the lever arm z̄. The centroid of a gravity wall lies at about 0.4 of its height and the centroid of the soil behind it higher still, so these moments are of the same order as that of the seismic thrust increment. The vertical inertia changes both N (sliding) and the restoring moment; the "kv up" case usually governs sliding and overturning, the "kv down" case can govern bearing.

What is not in the free body. Only the surcharge over the soil behind the wall is an excluded vertical load, so it has no inertia entry; the inertia of the surcharge on the sliding wedge is inside PAE. The fill over the front footing (W_SOIL_TOE) is a vertical load and gets IH_W_SOIL_TOE / IV_W_SOIL_TOE.

15Sliding, overturning and bearingDerivations including partial base contact.

14.1 Sliding

At the base underside the wall is held by friction. Summing horizontal forces on the free body, the base must supply the shear T = ΣHdrive − ΣPresist, while the available shear is μb·N (no adhesion is used). Placing all resistance in the numerator gives

FSs=μb·N+ΣPresistΣHdrive
N=Σ(−Fz)weights − uplift ± vertical inertia + the vertical components of the earth thrust
sliding surfaceΣHdriveμb·NPtoeN = Σ(−Fz)N = Σ(−Fz)weights − uplift ± kv·Wweights − uplift ± kv·WFSs = (μb·N + Ptoe) / ΣHdrive — the front resistance is used in sliding only
Figure 14.1 The free body cut along the base underside. The earth pressure, the water and the inertia drive it toward the front; the base friction μb·N and the resistance of the soil in front of the wall hold it back. N is the effective normal force, so the uplift reduces the friction.

μb = tan δb is the base friction coefficient; for masonry laid or concrete cast on the foundation soil δb is commonly taken between 2/3·φ′ and φ′ of that soil. N is an effective normal force because the uplift is part of it. Note that putting the passive resistance in the numerator gives a different number than subtracting it from the driving force; the definition must match the one the required factor of safety was calibrated for.

14.2 Overturning

FSo=ΣMresistingΣMoverturningmoments about the toe

Pivot. The wall overturns about the toe O — the front bottom corner of the footing (x = 0, z = 0). Each ledger entry contributes its two moment parts −z·Fx and x·Fz; positive parts are added to ΣMoverturning, negative parts (in absolute value) to ΣMresisting. Weights and the vertical component of an inclined thrust resist; horizontal thrusts, uplift, horizontal inertia and upward vertical inertia overturn. The front resistance is not included. Because a force may be counted on either side, FSo is not a unique measure of safety; the eccentricity check of the bearing calculation is the more robust indicator of the same mechanism.

14.3 Bearing pressure

The vertical load V = Σ(−Fz) and the total moment ΣM about the toe locate the resultant on the base. Its lever arm from the toe satisfies V·xR = −ΣM:

xR=−ΣMV
e=B/2−xRe > 0: the resultant lies toward the toe

Full contact. For a rigid base with a linear contact pressure, q(x) = V/B + (V·e)·(B/2 − x)/I with I = B³/12 per metre, so

q(x)=VB[1+12e(B/2−x)B2]
qtoe=VB(1+6eB),qheel=VB(1−6eB)

The pressure under the back edge stays compressive while |e| ≤ B/6 — the resultant lies in the middle third of the base.

VxRxReeqmax = V/B·(1 + 6e/B)qmax = V/B·(1 + 6e/B)qmin = V/B·(1 − 6e/B)qmin = V/B·(1 − 6e/B)(a) |e| ≤ B/6: trapezoidB/2VxR = a/3xR = a/3a = 3·xRa = 3·xRthe back of the base lifts offthe back of the base lifts offqmax = 2V/(3·xR)qmax = 2V/(3·xR)(b) |e| > B/6: partial contact
Figure 14.2 Contact pressure. (a) The resultant inside the middle third: trapezoidal pressure. (b) The resultant outside it: the back of the base lifts off and a triangular pressure over a length a = 3·xR carries V.

Partial contact. Soil cannot take tension, so beyond the middle third only part of the base is in contact. A triangular pressure of length a has its resultant at a/3 from the toe, which must coincide with xR; its area must equal V:

a/3=xR⇒a=3xR
12qmaxa=V⇒qmax=2V3xRwith e < 0 (the resultant toward the back edge) use B − xR in place of xR
CheckConditionNote
BEARINGqmax ≤ qallqall is an allowable pressure supplied by the user
ECCENTRICITY|e| ≤ B/6full base contact
QMINV/B·(1 − 6|e|/B) ≥ 0the unclipped linear value; negative means lift-off. The same condition as |e| ≤ B/6, so it is information only, not a separate check
Resultant outside the basexR ≤ 0 or xR ≥ Bthe wall overturns; bearing is not evaluated
About qall. A wall base carries an eccentric and inclined load. When qall is derived from a bearing-capacity formula, use the effective width B′ = B − 2|e| and load-inclination factors (the Bearing Capacity tools of GeoTerva give them) with the factor of safety of the governing code.

16Scope of the checksWhere the module’s checks end and the code checks of the masonry begin.

The checks of Section 14 treat the wall as one rigid block on its foundation: they are the external stability of the wall. A gravity wall of masonry or plain concrete can also fail inside itself, and those checks follow from the actions this module gives. They matter most for a tall or slender section, a dry-stone wall, a wall with weak mortar, and under the earthquake.

CheckWhat it asksWhere it is made
Compression in the bodyThe largest compressive stress on a horizontal section (bed joint) stays below the allowable stress of the masonry or concrete.masonry or concrete code
Tension in a jointThe resultant on every horizontal section stays inside its middle third (no tension in the joint), or inside a limit allowed for the material.masonry or concrete code
Sliding on a joint or a liftThe friction on a bed joint, or on the construction joint at the footing top, carries the horizontal force above it.masonry or concrete code
Stability of the body above the footingOverturning and sliding of the body about the footing top (z = Hfl, Hfr).masonry or concrete code
Global (deep-seated) stabilityA slip surface passing under the wall through the foundation and the backfill.slope stability analysis
Settlement, seepage, frost, drainageServiceability of the foundation, piping at the toe, the drainage of the backfill.foundation and drainage design
The external checks of this tool are necessary, not sufficient: a design must also satisfy the internal checks of the governing masonry or concrete code.
Hand check of a joint. For a horizontal section at height z the same ledger logic applies to the part of the wall above it: the weight of the wall above z, the earth and water pressure on its back face above z, and in a seismic case its inertia. Their resultant gives N, H and the eccentricity on that section; σ = N/b·(1 ± 6e/b) must stay compressive and below the allowable stress, and H ≤ μjoint·N.

17Worked example: a wall calculated step by stepA wall calculated step by step with engine numbers.

The example below is solved by the same engine that runs this tool, each time this page is opened. Every line shows the hand formula, the substituted input values and the result printed by the engine; the green tick confirms that the hand formula, evaluated independently in the page, gives the same number. The wall is the default section in stone masonry with a horizontal dry backfill, a surcharge and soil in front of the wall, so that every step can be followed by hand. The example is in SI units (kN, m, kPa) whatever display units are selected.

InputValueInputValue
Wall height H; top width Wu3.00 m; 1.00 mMoist unit weight γ18.00 kN/m³
Batters Wdl / Wdr0.50 / 0.50 mFriction angle φ′30.0°
Footing Wbl / Wbr; Hfl / Hfr0.50 / 0.50 m; 0.50 / 0.50 mUniform surcharge q10.00 kPa
Front ground Df; w, ηp,E, hignore1.00 m; 1/3, 0.00, 0.00 mBase friction μb0.55
Wall materialstone masonry, γm = 22.00 kN/m³Static methodRankine (vertical plane at x = B)
SeismicMononobe–Okabe, kh = 0.15, kv = 0Required FSstatic 1.50 / 2.00, seismic 1.10 / 1.10 (sliding / overturning)
q = 10.00 kPaq = 10.00 kPaPA = 27.00 kN/m at z = 1.000PA = 27.00 kN/m at z = 1.000Pq = 10.00 kN/m at z = 1.500Pq = 10.00 kN/m at z = 1.500Kₐ(γh + q) = 21.33 kPaKₐ(γh + q) = 21.33 kPaWm = 115.50Wm = 115.50Wsoil = 33.75Wsoil = 33.75Ptoe = 12.00Ptoe = 12.00(Kmob = 1.3333)(Kmob = 1.3333)qtoe = 58.44 kPaqtoe = 58.44 kPaqheel = 44.36 kPaqheel = 44.36 kPaH = 3.00H = 3.00Static case (SI units)
Figure 16.1 The example wall to scale with the static loads and the base pressure, all taken from the engine.

Static case

1
Geometry

Base width and the corners of the body (origin at the toe, base underside).

B = Wbl + Wdl + Wu + Wdr + Wbr = 0.50 + 0.50 + 1.00 + 0.50 + 0.50 = 3.000 m ✓
xFT = Wbl + Wdl = 1.000 m, xBT = xFT + Wu = 2.000 m, xBB = xBT + Wdr = 2.500 m; plane height h = H = 3.000 m ✓
2
Wall parts (Section 3)

Front block, front batter, core, back batter, back block.

A₁ = (Wbl + Wdl)·Hfl = 1.000·0.50 = 0.500 m² ✓; x̄₁ = 0.500 m ✓
A₂ = ½·Wdl·(H − Hfl) = ½·0.50·2.50 = 0.625 m² ✓; x̄₂ = Wbl + 2Wdl/3 = 0.833 m ✓; z̄₂ = 1.333 m ✓
A₃ = Wu·H = 1.00·3.00 = 3.000 m² ✓; x̄₃ = 1.500 m ✓
A₄ = ½·Wdr·(H − Hfr) = 0.625 m² ✓; x̄₄ = xBT + Wdr/3 = 2.167 m ✓; A₅ = (Wdr + Wbr)·Hfr = 0.500 m² ✓; x̄₅ = 2.500 m ✓
Wm = γm·ΣA = 22.00·5.250 = 115.50 kN/m ✓; ΣWix̄i = 173.25 kN·m/m ✓; x̄m = 1.500 m ✓; z̄m = 1.222 m ✓
PartA (m²)W (kN/m)x̄ (m)z̄ (m)W·x̄ (kN·m/m)
Front block (footing and the body above it up to H_fl)0.50011.000.5000.2505.50
Front batter of the body0.62513.750.8331.33311.46
Core of the body (top width W_u, full height)3.00066.001.5001.50099.00
Back batter of the body0.62513.752.1671.33329.79
Back block (footing and the body above it up to H_fr)0.50011.002.5000.25027.50
Total5.250115.501.5001.222173.25
Check against the whole outline as one polygon: ΔA = 0.000000000000 m² ✓
3
Soil moving with the wall (Section 4)

Flat ground: the block behind the wall is a rectangle over the back footing plus the triangle against the back batter, all moist.

Asoil = Wbr·(H − Hfr) + ½·Wdr·(H − Hfr) = 1.250 + 0.625 = 1.875 m²; Wsoil = γ·A = 18.00·1.875 = 33.75 kN/m ✓
x̄ = (1.250·2.750 + 0.625·2.333)/1.875 = 2.611 m ✓; z̄ = 1.889 m ✓
Fill over the front footing (Df = 1.00 m > Hfl): a trapezoid of height Df − Hfl = 0.50 m, widths 0.500 → 0.600 m: Wtoe = 18.00·0.2750 = 4.95 kN/m ✓ at x̄ = 0.276 m ✓, z̄ = 0.758 m ✓
Excluded: Q = q·(B − xBT) = 10.00 kN/m ✓ (removable load — listed in the ledger, used in no check)
4
Earth-pressure coefficients (Sections 6 and 8)

φ′ = 30.0°, sin φ′ = 0.5000.

Ka = (1 − sin φ′)/(1 + sin φ′) = 0.3333 ✓
Kp = tan²(45° + φ′/2) = 3.0000 ✓; K0 = 1 − sin φ′ = 0.5000 ✓
Kmob = w·Kp + (1 − w)·K0 = 1/3·3.0000 + 2/3·0.5000 = 1.3333 ✓
5
Static thrusts

Triangle for the soil, rectangle for the surcharge; lever arms above the base underside.

PA = ½·Ka·γ·h² = ½·0.3333·18.00·3.00² = 27.00 kN/m ✓ at z = h/3 = 1.000 m ✓
Pq = Ka·q·h = 0.3333·10.00·3.00 = 10.00 kN/m ✓ at z = h/2 = 1.500 m ✓
6
Front passive resistance (Section 8)

Kmob, c′ = 0, hignore = 0: a triangle from the front ground to the base underside, credited in full.

Ptoe = ½·Kmob·γ·Df² = ½·1.3333·18.00·1.00² = 12.00 kN/m ✓ at z̄ = Df/3 = 0.333 m ✓
7
Force ledger — static

Every force with its components, point of application and moment about the toe.

ForceFx (kN/m)Fz (kN/m)x (m)z (m)M (kN·m/m)Used
W_CONCRETEWall self-weight (stone masonry, body and footing)0.00−115.501.5001.222−173.25SOB
W_SOIL_HEELSoil moving with the wall (behind the body, to the vertical plane at x = B)0.00−33.752.6111.889−88.13SOB
Q_HEELSurcharge over the soil behind the wall (excluded: variable load)0.00−10.002.5003.000−25.00–
W_SOIL_TOEFront fill over the front footing (moves with the wall)0.00−4.950.2760.758−1.36SOB
PA_STATICStatic active earth pressure — soil (Rankine)−27.000.003.0001.00027.00SOB
PA_QSurcharge lateral pressure−10.000.003.0001.50015.00SOB
PP_FRONTToe passive resistance Ptoe (Kmob = 1.3333, w = 0.333)12.000.000.0000.333−4.00S
S = sliding, O = overturning, B = bearing, – = listed but used in no check. M = x·Fz − z·Fx about the toe; positive = overturning.
8
Sliding (Section 14.1)
N = Wm + Wsoil + Wtoe = 115.50 + 33.75 + 4.95 = 154.20 kN/m ✓; μb·N = 0.55·154.20 = 84.81 kN/m ✓
Hdrive = PA + Pq = 27.00 + 10.00 = 37.00 kN/m ✓; Ptoe = 12.00 kN/m ✓
FSs = (84.81 + 12.00) / 37.00 = 2.616 ✓ ≥ 1.50
9
Overturning (Section 14.2)

Moments about the toe O; the passive resistance is not used.

ΣMoverturning = PA·zA + Pq·zq = 27.00 + 15.00 = 42.00 kN·m/m ✓
ΣMresisting = Wm·x̄m + Wsoil·x̄soil + Wtoe·x̄toe = 173.25 + 88.13 + 1.36 = 262.74 kN·m/m ✓
FSo = 262.74 / 42.00 = 6.256 ✓ ≥ 2.00
10
Bearing (Section 14.3)
V = 154.20 kN/m ✓; ΣM = 42.00 − 262.74 = −220.74 kN·m/m ✓
xR = −ΣM/V = 220.74/154.20 = 1.432 m ✓; e = B/2 − xR = 1.500 − 1.432 = 0.068 m ✓ ≤ B/6 = 0.500 m
qmax = V/B·(1 + 6e/B) = 154.20/3.000·(1 + 6·0.068/3.000) = 58.44 kPa ✓ ≤ qall = 200.00 kPa; qmin = 44.36 kPa ✓
q = 10.00 kPaq = 10.00 kPaPAE = 48.06 kN/m at z = 1.288PAE = 48.06 kN/m at z = 1.2881.6·ΔP/h = 5.90 kPa1.6·ΔP/h = 5.90 kPa0.4·ΔP/h = 1.47 kPa0.4·ΔP/h = 1.47 kPakₕWm = 17.32kₕWm = 17.32kₕWsoil = 5.06kₕWsoil = 5.06qheel = 10.23 kPaqheel = 10.23 kPaqmax = 92.57 kPaqmax = 92.57 kPaSeismic case, kₕ = 0.15, kᵥ = 0 (SI units)
Figure 16.2 The seismic case: the Mononobe–Okabe thrust with its increment (inverted trapezoid, Section 11.3), the inertia of the wall and of the soil behind it, and the resulting base pressure. The seismic passive credit is ηp,E·Ptoe = 0 by default.

Seismic case

1
Seismic angle and KAE (Section 11.1)

Vertical plane, δ = β = ψ = 0, kv = 0, so cos θ·cos(δ + ψ + θ) = cos²θ.

θ = tan⁻¹(kh/(1 − kv)) = tan⁻¹(0.15) = 8.531° ✓
KAE = cos²(φ′ − θ) / (cos²θ·(1 + √(sin φ′·sin(φ′ − θ)/cos θ))²) = 0.8660 / (0.9780·(1 + 0.4302)²) = 0.4329
PAE = (½·γ·h² + q·h)·KAE = (81.00 + 30.00)·0.4329 = 48.06 kN/m ✓
2
Increment and its height (Section 11.3)

The static part keeps its shape; the increment acts at 0.6·h.

ΔPAE = PAE − (PA + Pq) = 48.06 − 37.00 = 11.06 kN/m ✓
zAE = (PA·h/3 + Pq·h/2 + ΔPAE·0.6h)/PAE = 1.288 m ✓
3
Inertia (Section 13)

Horizontal inertia at the centroids; no vertical inertia (kv = 0).

kh·Wm = 0.15·115.50 = 17.32 kN/m ✓ at z̄m = 1.222 m
kh·Wsoil = 0.15·33.75 = 5.06 kN/m ✓ at z̄ = 1.889 m; kh·Wtoe = 0.74 kN/m ✓ at z̄ = 0.758 m
4
Seismic passive credit (Section 11.2)

No seismic passive coefficient.

creditE = ηp,E·Ptoe = 0.00·12.00 = 0.00 kN/m ✓ (no passive credit in the seismic case)
5
Force ledger — seismic
ForceFx (kN/m)Fz (kN/m)x (m)z (m)M (kN·m/m)Used
W_CONCRETEWall self-weight (stone masonry, body and footing)0.00−115.501.5001.222−173.25SOB
W_SOIL_HEELSoil moving with the wall (behind the body, to the vertical plane at x = B)0.00−33.752.6111.889−88.13SOB
Q_HEELSurcharge over the soil behind the wall (excluded: variable load)0.00−10.002.5003.000−25.00–
W_SOIL_TOEFront fill over the front footing (moves with the wall)0.00−4.950.2760.758−1.36SOB
PAE_TOTALTotal seismic active earth pressure incl. surcharge (Mononobe–Okabe)−48.060.003.0001.28861.90SOB
IH_W_CONCRETEHorizontal inertia kₕ·W — wall−17.320.001.5001.22221.18SOB
IH_W_SOIL_HEELHorizontal inertia kₕ·W — soil behind the wall−5.060.002.6111.8899.56SOB
IH_W_SOIL_TOEHorizontal inertia kₕ·W — front fill−0.740.000.2760.7580.56SOB
S = sliding, O = overturning, B = bearing, – = listed but used in no check. M = x·Fz − z·Fx about the toe; positive = overturning.
6
Sliding and overturning
Hdrive = 48.06 + 17.32 + 5.06 + 0.74 = 71.19 kN/m ✓; FSs = (84.81 + 0.00)/71.19 = 1.191 ✓ ≥ 1.10
ΣMoverturning = 61.90 + 21.18 + 9.56 + 0.56 = 93.20 kN·m/m ✓; FSo = 262.74/93.20 = 2.819 ✓ ≥ 1.10
7
Bearing (Section 14.3)

The resultant moves toward the toe but stays in the middle third.

ΣM = 93.20 − 262.74 = −169.54 kN·m/m ✓; xR = 169.54/154.20 = 1.099 m ✓; e = 0.401 m ✓ ≤ B/6 = 0.500 m
qmax = V/B·(1 + 6e/B) = 92.57 kPa ✓ ≤ qall = 200.00 kPa
CheckStaticRequiredSeismicRequired
Sliding FS2.6161.501.1911.10
Overturning FS6.2562.002.8191.10
qmax (kPa)58.44200.0092.57200.00
|e| (m)0.0680.5000.4010.500
Every check is satisfied in both cases. The margin under the earthquake is much smaller than in the static case: the inertia of the heavy wall itself (17.32 kN/m) is as large as the seismic increment of the thrust (11.06 kN/m). A good exercise is to change Wbr or Wu in the Model tab, press Analyze and follow the same steps in the Calculations tab.

18VariablesEvery symbol used in the tool.

HTotal wall height, base underside → wall top
WuTop width of the body
Wdl, WdrFront and back batter offsets of the body
Wbl, WbrFront and back footing projections
Hfl, HfrFront and back footing heights
BBase width, Wbl + Wdl + Wu + Wdr + Wbr
x, zCoordinates from the toe on the base underside; x toward the backfill, z upward
xFB, xFT, xBT, xBBFront face of the body at the footing top and at the wall top; back face at the wall top and at the footing top
Df, hignoreFront ground height above the base underside; unreliable top layer of the front soil
βBackfill surface inclination
γ, γsat, γ′Moist, saturated and submerged unit weight of the soil
γm, γwUnit weight of the wall material (stone masonry 22, plain concrete 24 kN/m³ by default) and of water
n, γdPorosity and dry (skeleton) unit weight of the backfill, from γsat with Gs = 2.65 (internal constant)
φ′Effective friction angle of the backfill
δInclination of the thrust to the plane normal (δ = β on the vertical plane)
α, ρInclination of the back plane (α = 90°) and of a trial failure plane from the horizontal
σ′v, uEffective vertical stress and pore pressure
Kₐ, KₐβRankine active coefficients: horizontal and sloping ground
Kₚ, K₀Passive and at-rest coefficients
w, Kmob, ηₚ,EPassive state weight (1/3 default), Kmob = w·Kₚ + (1 − w)·K₀, seismic passive credit factor (0)
qUniform surcharge on the backfill
kₕ, kᵥHorizontal and vertical pseudo-static coefficients
θSeismic angle tan⁻¹(kₕ/(1 ± kᵥ))
KAEMononobe–Okabe active coefficient
PAE, ΔPAETotal seismic active thrust and its increment over the static-case thrust PA on the same plane
h, hₑHeight of the pressure plane, zground(B); height over which the seismic increment is distributed
zw, zw,rear, hwGroundwater depth below the wall top (input); retained water table elevation H − zw; water column height on the plane
hwfFront water height above the base underside
utoe, uheel, U, xUPore pressure at the toe and at the back edge of the base (heel), uplift resultant and its distance from the toe
PhdHydrodynamic thrust
Wm, Wsoil, WtoeWeight of the wall, of the soil behind it and of the fill over the front footing
FSs, FSoFactors of safety against sliding and overturning
μbBase friction coefficient
xR, eResultant position from the toe; eccentricity B/2 − xR
qmax, qmin, qallContact pressures and the allowable pressure
aContact length with partial contact, 3·xR

19ReferencesThe three theories and the source used.

The three theories of the tool and the source whose presentation of their closed forms (Ka, Kp, KAE) the manual follows. Everything not derived from them is an assumption of this module and is marked so in the text.

  1. Coulomb C.A. (1776) Essai sur une application des règles de maximis et minimis à quelques problèmes de statique relatifs à l'architecture. Mémoires de l'Académie Royale des Sciences 7, Paris.
  2. Das B.M. (2016) Principles of Foundation Engineering, 8th ed. Cengage Learning, Boston.
  3. Mononobe N., Matsuo H. (1929) On the determination of earth pressures during earthquakes. Proceedings of the World Engineering Congress, Tokyo, 9:177–185.
  4. Okabe S. (1926) General theory of earth pressure. Journal of the Japanese Society of Civil Engineers 12(1).
  5. Rankine W.J.M. (1857) On the stability of loose earth. Philosophical Transactions of the Royal Society of London 147:9–27.

From theory to your own design

Check your own gravity wall in minutes

  • The factors of safety for sliding and overturning, the eccentricity and the bearing pressure
  • Static and seismic cases, with water, a surcharge and the passive resistance in front of the footing
  • Every force in a ledger you can follow
  • A clean calculation report, saved as a PDF. Online: nothing to install, no dongle, on a phone, a tablet or a PC