GeoTerva Open the module

Formulas and tables · Stress distribution

Stress below a line load: Flamant’s solution

The stresses a load per unit length along a straight line causes in an elastic half-space: Δσz, Δσx and τxz of a vertical line load, the vertical stress below a horizontal one, a table against x/z, and when a narrow footing may be treated as a line.

  • Free to read
  • x/z = 0–5
  • Vertical and horizontal
  • Worked example

1The vertical line loadFlamant (1892).

A line load q (kN/m) acts along an infinite straight line on the surface: a long wall on a narrow footing, a rail, a strip so narrow that its width does not matter. Every cross section is loaded alike, so the stresses depend only on the horizontal distance x from the line and the depth z. Summing Boussinesq’s (1883) point-load solution (see Boussinesq point load) along the line, Flamant (1892) obtained:

Δσz=2qz3π(x2+z2)2,Δσx=2qx2zπ(x2+z2)2,τxz=2qxz2π(x2+z2)2

None of the three depends on the elastic constants. Divided by q/z, the vertical stress is one curve for every line load:

Δσzq/z=2π[(x/z)2+1]2

Directly below the load Δσz = 2q/(πz) = 0.637q/z: it decreases only as 1/z, not as 1/z² as below a point load. At x = z it is 0.159q/z, a quarter of the value on the axis.

In polar co-ordinates about the load, with ρ the distance from it and θ the angle from the vertical, the stress is purely radial:

σρ=2qπcos⁡θρ,σθ=τρθ=0

so the lines of equal radial stress are circles tangent to the surface at the load: a circle of diameter D carries σρ = 2q/(πD) all round. These are the pressure bulbs of the line load.

2The horizontal line loadΔσz = 2qxz²/[π(x² + z²)²].

A line load may also push along the surface: the friction under a long wall base, the braking of a track, the thrust of an arch. For a horizontal line load q acting towards +x, the vertical stress increase is

Δσz=2qxz2π(x2+z2)2

positive (compression) ahead of the load and negative behind it; its largest value, 0.2067q/z, lies at x/z = 1/√3 = 0.577. It is the same expression as τxz of the vertical load. An inclined line load is split into its components, q cos β vertically and q sin β horizontally, and their stresses are added.

3Table of the stressesDivided by q/z, against x/z.

Table 1. Stresses below a line load, divided by q/z, against x/z
x/zΔσz vertical loadΔσx vertical loadτxz vertical load = Δσz horizontal load
0.00.63660.00000.0000
0.10.62410.00620.0624
0.20.58860.02350.1177
0.30.53580.04820.1607
0.40.47310.07570.1892
0.50.40740.10190.2037
0.60.34420.12390.2065
0.70.28680.14050.2007
0.80.23670.15150.1894
0.90.19430.15740.1749
1.00.15920.15920.1592
1.20.10690.15400.1283
1.40.07270.14240.1017
1.60.05020.12860.0804
1.80.03540.11470.0637
2.00.02550.10190.0509
2.50.01210.07570.0303
3.00.00640.05730.0191
4.00.00220.03520.0088
5.00.00090.02350.0047

The horizontal load acts towards +x; behind it (x < 0) its Δσz has the opposite sign, and τxz of the vertical load changes sign across the line. Δσx = Δσz(x/z)². Values computed by GeoTerva with the functions its line load modules use.

4Worked exampleA wall beside a buried pipe.

A long masonry wall applies q = 60 kN/m to the ground through a footing 0.6 m wide. A pipe runs parallel to it at a horizontal distance of x = 1.5 m and a depth of z = 2 m. Treating the wall as a line load:

  • x/z = 0.75, [(x/z)² + 1]² = 1.5625² = 2.4414, 2/(π × 2.4414) = 0.2608, and q/z = 30.0 kPa: Δσz = 30.0 × 0.2608 = 7.82 kPa. The horizontal stress on the pipe is Δσx = Δσz(x/z)² = 4.40 kPa.
  • As a strip of width 0.6 m carrying 100 kPa, the same point receives 7.91 kPa (see stress below a strip load): at this distance the width of the footing hardly matters.
  • If the wall also transmits a horizontal force of 8 kN/m towards the pipe, it adds 0.782 kPa; the inclined load gives Δσz = 7.823 + 0.782 = 8.605 kPa.

Directly below the wall the line load is a poor model close to the footing and a good one further down:

Table 2. Below the centre of the wall: the line load against the strip of the footing
z (m)z/BΔσz line load (kPa)Δσz strip (kPa)line/strip
0.30.5127.381.81.556
0.61.063.755.01.158
0.91.542.439.61.072
1.22.031.830.61.041
1.83.021.220.81.018
3.05.012.712.61.007
4.57.58.58.51.003

q = 60 kN/m; strip B = 0.6 m, 100 kPa. Values computed by GeoTerva with the functions its line load and strip load modules use.

5QuestionsShort answers.

Why does the stress below a line load fall off as 1/z?

A point load spreads over an area that grows as z², so its stress falls as 1/z². A line load spreads only sideways, over a width that grows as z, so Δσz = 2q/(πz) on its axis falls as 1/z: a long load reaches much deeper.

When can a narrow footing be treated as a line load?

When the point is far from it compared with its width. Below the centre of a strip of width B, the line load of the same total force overestimates Δσz by 16 % at z = B, 4 % at z = 2B and 2 % at z = 3B (Table 2 shows the same for the wall of the worked example).

Is this the lateral pressure of a line load on a wall?

Not directly. Δσx here is the horizontal stress in a free half-space. A wall that does not yield restrains the soil, and its elastic pressure is twice that Δσx; the line load surcharge article gives it, with the resultant and its line of action.

The theory behind it