1The vertical line loadFlamant (1892).
A line load q (kN/m) acts along an infinite straight line on the surface: a long wall on a narrow footing, a rail, a strip so narrow that its width does not matter. Every cross section is loaded alike, so the stresses depend only on the horizontal distance x from the line and the depth z. Summing Boussinesq’s (1883) point-load solution (see Boussinesq point load) along the line, Flamant (1892) obtained:
None of the three depends on the elastic constants. Divided by q/z, the vertical stress is one curve for every line load:
Directly below the load Δσz = 2q/(πz) = 0.637q/z: it decreases only as 1/z, not as 1/z² as below a point load. At x = z it is 0.159q/z, a quarter of the value on the axis.
In polar co-ordinates about the load, with ρ the distance from it and θ the angle from the vertical, the stress is purely radial:
so the lines of equal radial stress are circles tangent to the surface at the load: a circle of diameter D carries σρ = 2q/(πD) all round. These are the pressure bulbs of the line load.
2The horizontal line loadΔσz = 2qxz²/[π(x² + z²)²].
A line load may also push along the surface: the friction under a long wall base, the braking of a track, the thrust of an arch. For a horizontal line load q acting towards +x, the vertical stress increase is
positive (compression) ahead of the load and negative behind it; its largest value, 0.2067q/z, lies at x/z = 1/√3 = 0.577. It is the same expression as τxz of the vertical load. An inclined line load is split into its components, q cos β vertically and q sin β horizontally, and their stresses are added.
3Table of the stressesDivided by q/z, against x/z.
| x/z | Δσz vertical load | Δσx vertical load | τxz vertical load = Δσz horizontal load |
|---|---|---|---|
| 0.0 | 0.6366 | 0.0000 | 0.0000 |
| 0.1 | 0.6241 | 0.0062 | 0.0624 |
| 0.2 | 0.5886 | 0.0235 | 0.1177 |
| 0.3 | 0.5358 | 0.0482 | 0.1607 |
| 0.4 | 0.4731 | 0.0757 | 0.1892 |
| 0.5 | 0.4074 | 0.1019 | 0.2037 |
| 0.6 | 0.3442 | 0.1239 | 0.2065 |
| 0.7 | 0.2868 | 0.1405 | 0.2007 |
| 0.8 | 0.2367 | 0.1515 | 0.1894 |
| 0.9 | 0.1943 | 0.1574 | 0.1749 |
| 1.0 | 0.1592 | 0.1592 | 0.1592 |
| 1.2 | 0.1069 | 0.1540 | 0.1283 |
| 1.4 | 0.0727 | 0.1424 | 0.1017 |
| 1.6 | 0.0502 | 0.1286 | 0.0804 |
| 1.8 | 0.0354 | 0.1147 | 0.0637 |
| 2.0 | 0.0255 | 0.1019 | 0.0509 |
| 2.5 | 0.0121 | 0.0757 | 0.0303 |
| 3.0 | 0.0064 | 0.0573 | 0.0191 |
| 4.0 | 0.0022 | 0.0352 | 0.0088 |
| 5.0 | 0.0009 | 0.0235 | 0.0047 |
The horizontal load acts towards +x; behind it (x < 0) its Δσz has the opposite sign, and τxz of the vertical load changes sign across the line. Δσx = Δσz(x/z)². Values computed by GeoTerva with the functions its line load modules use.
4Worked exampleA wall beside a buried pipe.
A long masonry wall applies q = 60 kN/m to the ground through a footing 0.6 m wide. A pipe runs parallel to it at a horizontal distance of x = 1.5 m and a depth of z = 2 m. Treating the wall as a line load:
- x/z = 0.75, [(x/z)² + 1]² = 1.5625² = 2.4414, 2/(π × 2.4414) = 0.2608, and q/z = 30.0 kPa: Δσz = 30.0 × 0.2608 = 7.82 kPa. The horizontal stress on the pipe is Δσx = Δσz(x/z)² = 4.40 kPa.
- As a strip of width 0.6 m carrying 100 kPa, the same point receives 7.91 kPa (see stress below a strip load): at this distance the width of the footing hardly matters.
- If the wall also transmits a horizontal force of 8 kN/m towards the pipe, it adds 0.782 kPa; the inclined load gives Δσz = 7.823 + 0.782 = 8.605 kPa.
Directly below the wall the line load is a poor model close to the footing and a good one further down:
| z (m) | z/B | Δσz line load (kPa) | Δσz strip (kPa) | line/strip |
|---|---|---|---|---|
| 0.3 | 0.5 | 127.3 | 81.8 | 1.556 |
| 0.6 | 1.0 | 63.7 | 55.0 | 1.158 |
| 0.9 | 1.5 | 42.4 | 39.6 | 1.072 |
| 1.2 | 2.0 | 31.8 | 30.6 | 1.041 |
| 1.8 | 3.0 | 21.2 | 20.8 | 1.018 |
| 3.0 | 5.0 | 12.7 | 12.6 | 1.007 |
| 4.5 | 7.5 | 8.5 | 8.5 | 1.003 |
q = 60 kN/m; strip B = 0.6 m, 100 kPa. Values computed by GeoTerva with the functions its line load and strip load modules use.
5QuestionsShort answers.
Why does the stress below a line load fall off as 1/z?
A point load spreads over an area that grows as z², so its stress falls as 1/z². A line load spreads only sideways, over a width that grows as z, so Δσz = 2q/(πz) on its axis falls as 1/z: a long load reaches much deeper.
When can a narrow footing be treated as a line load?
When the point is far from it compared with its width. Below the centre of a strip of width B, the line load of the same total force overestimates Δσz by 16 % at z = B, 4 % at z = 2B and 2 % at z = 3B (Table 2 shows the same for the wall of the worked example).
Is this the lateral pressure of a line load on a wall?
Not directly. Δσx here is the horizontal stress in a free half-space. A wall that does not yield restrains the soil, and its elastic pressure is twice that Δσx; the line load surcharge article gives it, with the resultant and its line of action.