1Why a curved surfaceWall friction bends the failure surface.
When a wall is pushed into a granular soil, the soil in front of it is lifted and slides up along the wall. The wall holds it down by friction, so the passive force on the soil is inclined at δ′ below the normal of the wall. That friction bends the failure surface: it is curved near the heel and straight near the ground surface, where the soil is in Rankine’s passive state. Coulomb’s plane cannot follow the curve; it gives a passive force that is too large, and the more so the larger δ′ (see Coulomb earth pressure). With δ′ = 0 the surface is a plane and every method returns Rankine’s
For all the methods on this page the passive force on a vertical wall of height H with a level granular backfill is written
acting at H/3 above the heel and inclined at δ′ to the normal of the wall: its horizontal component is Pp cos δ′.
2The log-spiral trial wedgeTerzaghi and Peck (1967).
The curved part of the surface is taken as a logarithmic spiral about a pole O:
Every radius of this spiral meets the curve at φ′ to its normal. The resultant of the normal and shear forces on a failure surface in a granular soil is also inclined at φ′ to the normal, so on the spiral it passes through O and drops out of a moment equation about O. The trial procedure of Terzaghi and Peck (1967):
- From the top of the wall A, draw a line at 45° − φ′/2 below the ground surface and choose a point C on it.
- Find the pole O on that line such that a spiral through the heel B passes through C.
- Above C the soil is in Rankine’s passive state: the vertical face through C, of depth d, carries Pd = ½γd²tan²(45° + φ′/2), horizontal, at d/3 above C.
- Take moments about O of the weight W of the soil between the wall, the spiral and that face, of Pd, and of the wall force P (at H/3, inclined at δ′):
The procedure is repeated for points C along the line; the smallest P is the passive force. The tables below come from this procedure carried out numerically, C by C, for each φ′ and δ′. Caquot and Kerisel (1948) tabulated passive coefficients on log-spiral surfaces for inclined walls and sloping ground; Shields and Tolunay (1973) analysed the same wedge by the method of slices.
3Lancellotta’s closed formA lower bound (Lancellotta 2002).
Lancellotta (2002) found a closed-form solution for a vertical wall and level backfill by the lower-bound theorem of plasticity:
with 2θ in radians; Kp cos δ′ is the coefficient of the horizontal component. Being a lower bound, it lies a little below the log-spiral wedge, which is an upper-bound type of mechanism; the exact value lies between the two, close to the log spiral.
4Table of the log-spiral Kpφ′ = 20–45°, every degree.
| φ′ | δ′/φ′ = 0 | δ′/φ′ = 1/3 | δ′/φ′ = 1/2 | δ′/φ′ = 2/3 | δ′/φ′ = 1 |
|---|---|---|---|---|---|
| 20° | 2.04 | 2.38 | 2.56 | 2.73 | 3.07 |
| 21° | 2.12 | 2.50 | 2.70 | 2.90 | 3.29 |
| 22° | 2.20 | 2.63 | 2.85 | 3.08 | 3.53 |
| 23° | 2.28 | 2.77 | 3.02 | 3.28 | 3.80 |
| 24° | 2.37 | 2.91 | 3.20 | 3.49 | 4.09 |
| 25° | 2.46 | 3.06 | 3.39 | 3.72 | 4.42 |
| 26° | 2.56 | 3.23 | 3.59 | 3.98 | 4.78 |
| 27° | 2.66 | 3.41 | 3.82 | 4.26 | 5.18 |
| 28° | 2.77 | 3.60 | 4.06 | 4.56 | 5.62 |
| 29° | 2.88 | 3.80 | 4.33 | 4.89 | 6.12 |
| 30° | 3.00 | 4.02 | 4.61 | 5.26 | 6.68 |
| 31° | 3.12 | 4.26 | 4.93 | 5.67 | 7.30 |
| 32° | 3.25 | 4.51 | 5.27 | 6.11 | 8.01 |
| 33° | 3.39 | 4.79 | 5.65 | 6.61 | 8.81 |
| 34° | 3.54 | 5.09 | 6.06 | 7.17 | 9.73 |
| 35° | 3.69 | 5.42 | 6.52 | 7.78 | 10.76 |
| 36° | 3.85 | 5.78 | 7.03 | 8.47 | 11.95 |
| 37° | 4.02 | 6.17 | 7.59 | 9.25 | 13.32 |
| 38° | 4.20 | 6.59 | 8.21 | 10.12 | 14.90 |
| 39° | 4.40 | 7.06 | 8.90 | 11.11 | 16.73 |
| 40° | 4.60 | 7.58 | 9.67 | 12.24 | 18.86 |
| 41° | 4.81 | 8.14 | 10.54 | 13.52 | 21.36 |
| 42° | 5.04 | 8.77 | 11.52 | 14.98 | 24.31 |
| 43° | 5.29 | 9.46 | 12.62 | 16.67 | 27.80 |
| 44° | 5.55 | 10.24 | 13.88 | 18.61 | 31.96 |
| 45° | 5.83 | 11.10 | 15.30 | 20.88 | 36.97 |
Pp = ½KpγH², inclined at δ′ to the normal of the wall. δ′/φ′ = 0 is Rankine’s tan²(45° + φ′/2). Values computed by GeoTerva with the function its log-spiral passive module uses (Terzaghi and Peck 1967).
5Log spiral, Coulomb, Rankine, LancellottaFour solutions side by side.
| φ′ | δ′/φ′ (δ′) | Rankine (δ′ = 0) | Coulomb | Log spiral | Lancellotta | Coulomb / log spiral |
|---|---|---|---|---|---|---|
| 25° | 1/3 (8.3°) | 2.46 | 3.12 | 3.06 | 3.03 | 1.02 |
| 25° | 1/2 (12.5°) | 2.46 | 3.55 | 3.39 | 3.30 | 1.05 |
| 25° | 2/3 (16.7°) | 2.46 | 4.08 | 3.72 | 3.56 | 1.10 |
| 25° | 1 (25°) | 2.46 | 5.60 | 4.42 | 4.00 | 1.27 |
| 30° | 1/3 (10°) | 3.00 | 4.14 | 4.02 | 3.95 | 1.03 |
| 30° | 1/2 (15°) | 3.00 | 4.98 | 4.61 | 4.44 | 1.08 |
| 30° | 2/3 (20°) | 3.00 | 6.11 | 5.26 | 4.93 | 1.16 |
| 30° | 1 (30°) | 3.00 | 10.10 | 6.68 | 5.80 | 1.51 |
| 35° | 1/3 (11.7°) | 3.69 | 5.68 | 5.42 | 5.28 | 1.05 |
| 35° | 1/2 (17.5°) | 3.69 | 7.36 | 6.52 | 6.16 | 1.13 |
| 35° | 2/3 (23.3°) | 3.69 | 9.96 | 7.78 | 7.09 | 1.28 |
| 35° | 1 (35°) | 3.69 | 22.97 | 10.76 | 8.85 | 2.13 |
| 40° | 1/3 (13.3°) | 4.60 | 8.15 | 7.58 | 7.28 | 1.08 |
| 40° | 1/2 (20°) | 4.60 | 11.77 | 9.67 | 8.92 | 1.22 |
| 40° | 2/3 (26.7°) | 4.60 | 18.72 | 12.24 | 10.71 | 1.53 |
| 40° | 1 (40°) | 4.60 | 92.59 | 18.86 | 14.39 | 4.91 |
Coulomb (1776): plane surface. Log spiral: Terzaghi and Peck (1967). Lancellotta (2002): closed-form lower bound. — : φ′ + δ′ ≥ 90°, no Coulomb solution. Values computed by GeoTerva.
At δ′ = φ′/3 the plane and the spiral differ by a few per cent; at δ′ = 2φ′/3 and φ′ = 40° Coulomb’s value is far too high. The curved-surface solutions stay close together.
| φ′ | δ′/φ′ | α = −10°: curved | α = −10°: Coulomb | α = 0: curved | α = 0: Coulomb | α = +10°: curved | α = +10°: Coulomb |
|---|---|---|---|---|---|---|---|
| 30° | 1/2 | 3.14 | 3.16 | 4.61 | 4.98 | 6.40 | 8.14 |
| 30° | 2/3 | 3.53 | 3.65 | 5.26 | 6.11 | 7.38 | 10.90 |
| 35° | 1/2 | 4.26 | 4.34 | 6.52 | 7.36 | 9.51 | 13.63 |
| 35° | 2/3 | 5.00 | 5.36 | 7.78 | 9.96 | 11.50 | 21.54 |
α > 0: the ground rises away from the wall. Curved: the log-spiral wedge of Terzaghi and Peck generalised to a sloping surface, as computed by the GeoTerva module (for α = 0 it is the wedge of Table 1).
6In an earthquakeThe passive resistance drops.
During an earthquake the inertia of the passive wedge helps to push it out, and the passive resistance falls as the horizontal seismic coefficient kh grows, faster still when a vertical acceleration acts as well. Pseudo-static analyses on curved surfaces give the reduced coefficient: Subba Rao and Choudhury (2005) with a log spiral and a planar part, and Lancellotta (2007), who extended his lower-bound solution to the seismic case. The seismic passive earth pressure module of GeoTerva works with the coefficients of Subba Rao and Choudhury; the active side of the same wall is covered by the Mononobe–Okabe coefficient.
7Worked exampleA thrust block pushed into dense sand.
A heavy concrete thrust block has a vertical face H = 2.5 m high, from the ground surface down, and is pushed horizontally into a dense sand with φ′ = 36° and γ = 18.5 kN/m³. The block is heavy enough not to rise, so the sand it lifts slides along its face and a wall friction δ′ = 2φ′/3 = 24° can be mobilised.
- Log spiral: Kp = 8.47, Pp = ½ × 8.47 × 18.5 × 2.5² = 489.9 kN/m.
- Components: horizontal Pp cos 24° = 447.5 kN/m; vertical Pp sin 24° = 199.3 kN/m, acting upward on the block — the block must weigh more than this for the assumed friction to develop.
- The critical surface: the spiral leaves the heel and sweeps ω = 33.9° to the point C, 3.53 m from the face and 1.80 m below the surface; from there the straight Rankine slip line reaches the surface 7.06 m in front of the block.
For the same block, Coulomb’s plane gives Kp = 11.15 (Pp = 644.4 kN/m, 32 % more), Lancellotta’s lower bound 7.67 (443.2 kN/m) and Rankine, with no wall friction, 3.85 (222.7 kN/m). The full passive force needs a large movement; in design it is usually divided by a factor or taken only partly mobilised.
8QuestionsShort answers.
Why does Coulomb’s method overestimate the passive pressure?
Coulomb’s and the log-spiral methods both try failure mechanisms and keep the one with the smallest passive force. With wall friction the real surface is curved, and a plane cannot follow it, so the smallest plane mechanism still gives too large a force: 28 % too large for φ′ = 35° and δ′ = 2φ′/3.
What wall friction can be counted on in passive resistance?
Positive δ′ needs the soil to rise relative to the wall. A heavy wall or block that cannot rise mobilises up to about 2φ′/3 against concrete; a light wall, or one pulled upward, does not, and δ′ should then be taken as zero. With δ′ = 0 the log spiral gives Rankine’s Kp (3.00 for φ′ = 30°, against 4.61 with δ′ = φ′/2).
How much movement mobilises the full passive resistance?
Much more than the active state needs: of the order of 0.5–1 % of the wall height in sand and more in clay, against about 0.1 % for the active state. Where such movement is not acceptable, only part of the passive resistance is relied on.