1The trial wedgeCoulomb (1776): a rigid wedge on a plane.
Coulomb (1776) treated the soil behind a wall as a rigid wedge that slides on a plane through the heel. Three forces hold it: its weight W, the reaction F on the failure plane, inclined at φ′ to the normal of that plane, and the force Pa from the wall, inclined at the wall friction angle δ′ to the normal of the back. With the back at θ to the vertical, the backfill at α and the trial plane at β to the horizontal, the closed force polygon gives
The wall must hold the most dangerous wedge: the active force is the maximum of Pa(β). θ is measured from the vertical, positive when the heel lies farther into the backfill than the top of the wall (the soil rests on the back), negative when the back leans out over the soil; α is positive when the backfill rises away from the wall.
2The active coefficientThe closed form of the maximum.
Pa acts at H/3 above the heel, inclined at δ′ to the normal of the back, that is at δ′ + θ below the horizontal:
With θ = α = δ′ = 0 the formula is Rankine’s (1 − sin φ′)/(1 + sin φ′). Wall friction lowers Ka a little and turns the thrust downward, which helps the wall against sliding and overturning. The root needs α ≤ φ′. For a vertical back and level ground the coefficients for every degree are on the earth pressure coefficients page.
3The wall friction angleWhat δ′ to use.
δ′ is the friction angle between the wall and the soil, not a property of the soil alone. For concrete or masonry cast against a granular backfill δ′ is commonly taken between φ′/2 and 2φ′/3; smoother faces mobilise less, and δ′ can never exceed φ′. The sign assumes that the backfill moves down relative to the wall, as it does when an active wedge forms; a wall that settles more than the soil behind it reverses the friction, and δ′ is then taken as zero.
Where the pressure is taken not on the wall itself but on a vertical plane through the heel of a cantilever or gravity wall, that plane lies in the soil: no wall friction acts on it, and the thrust is taken parallel to the backfill (δ′ = α), for which Coulomb’s and Rankine’s coefficients are the same (see Rankine with a sloping backfill).
4Tables of Kaδ′ = 2φ′/3 and δ′ = φ′/2.
| φ′ | θ = −10° α = 0° | θ = 0° α = 0° | θ = 0° α = 10° | θ = 0° α = 20° | θ = 10° α = 0° | θ = 10° α = 10° | θ = 10° α = 20° | θ = 20° α = 0° | θ = 20° α = 10° | θ = 20° α = 20° |
|---|---|---|---|---|---|---|---|---|---|---|
| 26° | 0.281 | 0.347 | 0.403 | 0.514 | 0.426 | 0.502 | 0.648 | 0.527 | 0.633 | 0.833 |
| 28° | 0.255 | 0.321 | 0.370 | 0.460 | 0.401 | 0.469 | 0.590 | 0.503 | 0.599 | 0.769 |
| 30° | 0.232 | 0.297 | 0.340 | 0.414 | 0.377 | 0.438 | 0.540 | 0.479 | 0.568 | 0.714 |
| 32° | 0.210 | 0.275 | 0.312 | 0.374 | 0.355 | 0.409 | 0.497 | 0.457 | 0.538 | 0.667 |
| 34° | 0.190 | 0.254 | 0.287 | 0.339 | 0.334 | 0.382 | 0.458 | 0.437 | 0.511 | 0.624 |
| 36° | 0.171 | 0.235 | 0.263 | 0.307 | 0.314 | 0.357 | 0.423 | 0.417 | 0.485 | 0.586 |
| 38° | 0.154 | 0.217 | 0.242 | 0.279 | 0.295 | 0.334 | 0.392 | 0.398 | 0.461 | 0.551 |
| 40° | 0.139 | 0.200 | 0.221 | 0.253 | 0.277 | 0.312 | 0.363 | 0.381 | 0.438 | 0.518 |
| 42° | 0.124 | 0.184 | 0.203 | 0.229 | 0.261 | 0.292 | 0.336 | 0.364 | 0.416 | 0.489 |
θ: inclination of the back from the vertical (+ heel toward the backfill); α: slope of the backfill (+ rising away from the wall). Values computed by GeoTerva with the function its Coulomb module uses.
| φ′ | θ = −10° α = 0° | θ = 0° α = 0° | θ = 0° α = 10° | θ = 0° α = 20° | θ = 10° α = 0° | θ = 10° α = 10° | θ = 10° α = 20° | θ = 20° α = 0° | θ = 20° α = 10° | θ = 20° α = 20° |
|---|---|---|---|---|---|---|---|---|---|---|
| 26° | 0.289 | 0.353 | 0.408 | 0.516 | 0.430 | 0.503 | 0.642 | 0.527 | 0.628 | 0.815 |
| 28° | 0.262 | 0.326 | 0.374 | 0.461 | 0.403 | 0.469 | 0.584 | 0.501 | 0.593 | 0.751 |
| 30° | 0.237 | 0.301 | 0.343 | 0.415 | 0.378 | 0.437 | 0.535 | 0.476 | 0.560 | 0.697 |
| 32° | 0.214 | 0.278 | 0.315 | 0.374 | 0.355 | 0.407 | 0.491 | 0.453 | 0.529 | 0.649 |
| 34° | 0.193 | 0.256 | 0.288 | 0.338 | 0.333 | 0.379 | 0.451 | 0.431 | 0.500 | 0.605 |
| 36° | 0.174 | 0.236 | 0.264 | 0.306 | 0.312 | 0.353 | 0.416 | 0.409 | 0.473 | 0.566 |
| 38° | 0.156 | 0.217 | 0.241 | 0.277 | 0.292 | 0.329 | 0.383 | 0.389 | 0.447 | 0.530 |
| 40° | 0.140 | 0.199 | 0.220 | 0.250 | 0.273 | 0.306 | 0.354 | 0.370 | 0.423 | 0.496 |
| 42° | 0.125 | 0.183 | 0.201 | 0.226 | 0.255 | 0.285 | 0.326 | 0.351 | 0.399 | 0.465 |
Values computed by GeoTerva.
5The passive coefficient and its limitsThe minimum of the wedges.
Pushed into the soil, the wall lifts a wedge; the reactions turn to the other side of their normals, and the passive force is the minimum over the trial wedges:
| φ′ | θ = 0° α = 0° | θ = 0° α = −10° | θ = 0° α = 10° | θ = −10° α = 0° | θ = 10° α = 0° |
|---|---|---|---|---|---|
| 20° | 2.414 | 1.726 | 3.275 | 2.932 | 2.117 |
| 25° | 3.124 | 2.174 | 4.464 | 4.028 | 2.617 |
| 30° | 4.143 | 2.775 | 6.314 | 5.745 | 3.292 |
| 35° | 5.680 | 3.614 | 9.417 | 8.637 | 4.235 |
| 40° | 8.147 | 4.838 | 15.193 | 14.043 | 5.609 |
α > 0: the ground in front of the wall rises away from it. Values computed by GeoTerva.
The limit of the plane wedge. The real passive failure surface is curved near the heel, and the more so the larger δ′. Coulomb’s plane then overestimates Kp, on the unsafe side. Against the log-spiral surface (vertical wall, level ground) Coulomb’s Kp for φ′ = 35° is 5 % higher at δ′ = φ′/3, 13 % at δ′ = φ′/2 and 28 % at δ′ = 2φ′/3; for φ′ = 40° and δ′ = 2φ′/3 it is 18.72 against 12.24, 53 % higher. Beyond about δ′ = φ′/3 the passive coefficient should be taken from a curved surface: see log-spiral passive earth pressure.
6Worked exampleA battered back, a sloping backfill, wall friction.
A concrete wall H = 5 m high has its back battered at θ = 12° (heel toward the fill) and retains a granular backfill sloping at α = 12°, with φ′ = 33°, γ = 18.5 kN/m³ and a wall friction δ′ = 22° (2φ′/3).
- Coefficient: the term under the root is sin 55° · sin 21° / (cos 34° · cos 0°) = 0.3541, and Ka = cos²21° / [cos²12° · cos 34° · (1 + √0.3541)²] = 0.432.
- Thrust: Pa = ½ × 18.5 × 5² × 0.432 = 99.9 kN/m, at H/3 = 1.67 m above the heel.
- Components: inclined at δ′ + θ = 34° below the horizontal, Ph = 82.8 kN/m and Pv = 55.8 kN/m.
- Critical wedge: the trial force Pa(β) is largest for a plane at β = 57.8° to the horizontal.
Without wall friction the same wall would have Ka = 0.445, Pa = 102.9 kN/m inclined at θ = 12° only (Ph = 100.7, Pv = 21.4 kN/m): friction lowers the horizontal push by 18 %. With a vertical back and the same δ′ and α, Ka = 0.308 and Ph = 66.1 kN/m: the battered back carries more of the fill. The Coulomb module of GeoTerva takes layers, a water table and a surcharge, and draws the critical wedge.
7QuestionsShort answers.
How is the inclination θ of the back measured?
From the vertical, positive when the heel lies farther into the backfill than the top of the wall, so that the soil rests on the back; negative when the back leans out over the soil. For φ′ = 30°, δ′ = 20° and a level backfill, Ka = 0.232 at θ = −10°, 0.297 at θ = 0 and 0.377 at θ = 10°.
What wall friction angle should I use?
For concrete or masonry against a granular backfill, usually φ′/2 to 2φ′/3; never more than φ′. On a vertical plane through the soil behind the heel (the usual pressure plane of a cantilever or gravity wall) there is no wall friction, and the thrust is taken parallel to the backfill.
Why should Coulomb’s Kp not be used with large wall friction?
Because the plane failure surface overestimates the passive resistance when δ′ is large: for φ′ = 35° and δ′ = 2φ′/3 Coulomb’s Kp is 28 % above the log-spiral value. A curved surface (log spiral) should be used beyond about δ′ = φ′/3.