1The mechanismThe piles and the soil between them move down together.
When piles stand close together in a clay, the soil between them can be carried down with them. The group then fails as one block — the piles and the soil they enclose — sheared along its perimeter and bearing on the clay under its base. Terzaghi and Peck (1967) treat the block as a deep footing of length Lg, width Bg and depth L, the length of the piles, with Lg and Bg measured to the outside of the outer piles:
n1 and n2 are the numbers of piles along the two sides, s1 and s2 their spacings and D their width; Lg is the longer side.
2The capacity of the blockShear on the four faces, bearing at the base.
The first term is the bearing of the base, cu,b the undrained strength of the clay under it; the second is the shear on the four faces, summed over the clay layers along the piles, ΔL the thickness of each layer and cu its undrained strength. On the faces clay shears against clay, not against the pile, so the full cu acts there, not the adhesion αcu of a single pile.
The capacity of the group is the lesser of the block and the piles acting individually:
Terzaghi and Peck compare the block with the sum of the single piles, ΣQu = nQu. The GeoTerva pile group module compares it with the piles reduced by the group efficiency, ηΣQu (see pile group efficiency), and prints the comparison with ΣQu as well when every layer is a clay. In layered ground it sums the shear of the faces layer by layer; on the faces of a sand layer it takes τ = K0σ′v tan φ′ with K0 = 1 − sin φ′ (Jaky, 1944), and a block whose base stands on sand bears as its piles do, nQp.
3The factor Nc*A deep rectangular footing on clay.
The base of the block is a deep rectangular footing on clay. Its bearing-capacity factor Nc* grows with the depth ratio L/Bg and falls as the block gets longer in plan: from 6.24 for a square block at the surface to 9.00 at L/Bg = 5, and from 5.20 to 7.64 for a very long one. Beyond L/Bg = 5 it does not grow further.
| L/Bg | Lg/Bg = 1 | Lg/Bg = 2 | Lg/Bg = 3 | Lg/Bg = ∞ |
|---|---|---|---|---|
| 0.0 | 6.24 | 5.72 | 5.51 | 5.20 |
| 0.5 | 7.04 | 6.52 | 6.26 | 5.86 |
| 1.0 | 7.70 | 7.16 | 6.89 | 6.40 |
| 1.5 | 8.18 | 7.62 | 7.35 | 6.82 |
| 2.0 | 8.50 | 7.92 | 7.65 | 7.11 |
| 2.5 | 8.71 | 8.11 | 7.83 | 7.32 |
| 3.0 | 8.84 | 8.22 | 7.95 | 7.46 |
| 3.5 | 8.92 | 8.29 | 8.02 | 7.55 |
| 4.0 | 8.97 | 8.33 | 8.05 | 7.61 |
| 4.5 | 8.99 | 8.35 | 8.07 | 7.63 |
| 5.0 | 9.00 | 8.36 | 8.08 | 7.64 |
Between the curves Nc* is interpolated linearly in Lg/Bg (from 1 to 3) and in Bg/Lg (beyond 3); the value at L/Bg = 5 holds for deeper blocks. Values from the function the GeoTerva pile group module uses.
4Block or single piles?How the spacing decides.
The block carries more than the piles when they are far apart and less when they are close: the perimeter and the base of the block grow with the spacing, the shafts of the piles do not. Table 2 follows a group of 4 × 4 driven piles (D = 0.40 m, L = 15 m) in a soft clay with cu = 25 kPa as the spacing changes.
| s/D | s (m) | Lg = Bg (m) | Nc* | Qblock (kN) | ΣQu (kN) | Lesser of the two | ηΣQu (kN) |
|---|---|---|---|---|---|---|---|
| 2.00 | 0.80 | 2.80 | 9.00 | 5964 | 7012 | block | 3907 |
| 2.25 | 0.90 | 3.10 | 9.00 | 6812 | 7012 | block | 4212 |
| 2.50 | 1.00 | 3.40 | 8.99 | 7698 | 7012 | single piles | 4464 |
| 3.00 | 1.20 | 4.00 | 8.95 | 9580 | 7012 | single piles | 4858 |
| 4.00 | 1.60 | 5.20 | 8.81 | 13757 | 7012 | single piles | 5372 |
| 5.00 | 2.00 | 6.40 | 8.65 | 18458 | 7012 | single piles | 5690 |
ΣQu: 16 single piles, α method on the shaft and 9cuAb at the base; ηΣQu: the same with the Converse–Labarre efficiency. Values computed by GeoTerva with the functions of its pile group module.
Here the block governs up to s/D = 2.25 and the single piles from s/D = 2.50 on. With the efficiency applied to the piles (last column) the piles stay below the block at every spacing of the table. The block governs over ηΣQu as well in large groups of long, closely spaced piles in a very soft clay: 8 × 8 piles of D = 0.40 m and L = 30 m at 2D in a clay with cu = 10 kPa give Qblock = 10440 kN against ηΣQu = 12015 kN.
5Worked exampleA 4 × 4 group in soft clay at s = 2D.
Sixteen driven piles, D = 0.40 m and L = 15 m, stand in 4 rows of 4 at s = 0.80 m (2D) in a soft clay with cu = 25 kPa.
- The block: Lg = Bg = (4 − 1) × 0.80 + 0.40 = 2.80 m, perimeter 2(Lg + Bg) = 11.20 m. The faces: 25 × 11.20 × 15 = 4200 kN. The base: L/Bg = 5.36 and Lg/Bg = 1.00 give Nc* = 9.00, so 25 × 9.00 × 2.80 × 2.80 = 1764 kN. Qblock = 5964 kN.
- One pile alone: α = 0.87 (cu/pa = 0.25), Qs = 0.87 × 25 × π × 0.40 × 15 = 410.0 kN, Qp = 9 × 25 × 0.1257 = 28.3 kN, Qu = 438.3 kN; ΣQu = 16 × 438.3 = 7012 kN.
- The lesser: Qg(u) = min(7012, 5964) = 5964 kN: the block governs, 15 % below the sum of the piles.
At s = 1.00 m (2.5D) the same block carries 7698 kN and the single piles govern. The GeoTerva module also reduces the piles by the Converse–Labarre efficiency, η = 0.557 at 2D, which gives ηΣQu = 3907 kN, and takes the lesser of that and the block. How a load on the cap is shared among the sixteen piles is the subject of the load on each pile.
6QuestionsShort answers.
When does block failure govern?
When the piles are close together in a soft clay: the block’s perimeter is then short compared with the total perimeter of the shafts. In the example on this page it governs up to s = 2.25D and no longer at 2.50D. A large group of long piles in very soft clay is the case to check with most care.
Why is the full cu used on the faces of the block?
On the faces of the block the clay shears against clay, not against the pile surface, so the undrained strength acts in full; the adhesion factor α of a single pile describes the pile–soil interface and does not apply there.
Is block failure checked in sand?
The classical check is for clay. In layered ground GeoTerva still forms the block: a sand layer contributes τ = K0σ′v tan φ′ on the faces and a base on sand bears as the piles do; in a sand the efficiency of the piles is usually the governing group effect.