GeoTerva Open the module

Formulas and tables · Bearing capacity

Shape, depth and inclination factors: the general bearing-capacity equation

The factors that turn the strip-footing solution into a square, rectangular or embedded footing under an inclined load, with their values for a square footing at Df = B.

  • Free to read
  • φ = 0–45°
  • De Beer · Hansen · Meyerhof
  • Square footing

1The general equationEach term multiplied by its factors.

qu=cFcsFcdFciNc+qFqsFqdFqiNq+12γBFγsFγdFγiNγ

The factors Nc, Nq and Nγ are those of the strip footing (see bearing capacity factors); the F-factors correct for the footing’s shape, its depth and the inclination of the load.

2Shape factorsDe Beer (1970).

Fcs=1+BLNqNc,Fqs=1+BLtan⁡φ,Fγs=1−0.4BL

3Depth factorsHansen (1970).

Fcd=1+0.4DfB,Fqd=1+2tan⁡φ(1−sin⁡φ)2DfB,Fγd=1

for Df/B ≤ 1; for Df/B > 1 the ratio Df/B is replaced by tan−1(Df/B) in radians.

4Inclination factorsMeyerhof (1963).

Fci=Fqi=(1−β90°)2,Fγi=(1−βφ)2

β is the inclination of the load from the vertical; Fγi = 0 when β ≥ φ.

5Table for a square footingB/L = 1, Df/B = 1.

Table 1. Shape and depth factors for a square footing with Df = B
φ (°)Nq/NcFcsFqsFγsFcdFqdFγd
00.191.1951.0000.6001.4001.0001.000
50.241.2421.0870.6001.4031.1461.000
100.301.2961.1760.6001.4041.2411.000
150.361.3591.2680.6001.3941.2941.000
200.431.4311.3640.6001.3741.3151.000
250.511.5151.4660.6001.3431.3111.000
300.611.6111.5770.6001.3051.2891.000
350.721.7221.7000.6001.2631.2551.000
400.851.8521.8390.6001.2181.2141.000
451.012.0072.0000.6001.1731.1721.000

Values computed by GeoTerva with the functions its bearing-capacity modules use.

6QuestionsShort answers.

Why are there different shape factors in different books?

Meyerhof, Hansen, Vesic and De Beer each proposed their own; each set belongs with its own Nγ. This page gives the set the general equation of the GeoTerva modules uses.

Should depth factors always be used?

They add the shear strength of the soil above the base. Many engineers ignore them when that soil may be removed or is weak, which is on the safe side.

What does Fγs = 0.6 mean for a square footing?

The self-weight term of a square footing is 60 % of the strip footing’s: Fγs = 1 − 0.4·B/L.

The theory behind it