GeoTerva Open the module

Formulas and tables · Bearing capacity

Bearing capacity factors Nc, Nq, Nγ: formulas and tables

The three factors of the bearing-capacity equation for every friction angle from 0° to 50°: Terzaghi’s own factors and those of the general equation, with the Nγ of Meyerhof, Hansen and Vesic side by side.

  • Free to read
  • φ = 0–50°
  • 4 methods
  • Worked example

1What the factors areThe three terms of the bearing-capacity equation.

The bearing-capacity factors Nc, Nq and Nγ are dimensionless numbers that depend only on the friction angle φ of the soil. They weigh the three contributions to the ultimate bearing capacity qu of a strip footing: the cohesion c, the surcharge q = γDf at the base level and the self-weight of the soil below the base:

qu=cNc+qNq+12γBNγ

All three grow quickly with φ: from φ = 30° to φ = 40° Nq roughly triples. A small error in φ therefore matters far more than one in γ or B.

2Terzaghi’s factorsNq and Nc in closed form, Nγ from a table.

Terzaghi (1943) derived Nq and Nc from a logarithmic-spiral failure zone below a rough base:

Nq=e2(3π/4−φ/2)tan⁡φ2cos2(45°+φ/2)
Nc=(Nq−1)cot⁡φ(Nc=5.70 for φ=0)

His Nγ has no closed form; the values in the table below are those of Kumbhojkar (1993), the ones the Terzaghi module of GeoTerva reads. With Terzaghi’s factors, a square footing takes 1.3cNc and 0.4γBNγ, a circular one 1.3cNc and 0.3γBNγ.

3Factors of the general equationReissner, Prandtl, and three forms of Nγ.

The general bearing-capacity equation (Meyerhof, Hansen, Vesic) uses the closed forms of Reissner (1924) and Prandtl (1921):

Nq=eπtan⁡φtan2(45°+φ/2)
Nc=(Nq−1)cot⁡φ(Nc=5.14 for φ=0)

For Nγ the three authors differ:

NγMeyerhof=(Nq−1)tan⁡(1.4φ)
NγHansen=1.5(Nq−1)tan⁡φ
NγVesic=2(Nq+1)tan⁡φ

Each set of factors belongs with its own shape, depth and inclination factors: mixing Terzaghi’s Nγ with the shape factors of the general equation, or Vesic’s Nγ with Terzaghi’s coefficients, gives a capacity that neither method supports.

4Table of the factors, φ = 0–50°Every degree, four methods.

Table 1. Bearing-capacity factors by friction angle
φ (°)Nc TerzaghiNq TerzaghiNγ TerzaghiNc generalNq generalNγ MeyerhofNγ HansenNγ Vesic
05.701.000.005.141.000.000.000.00
16.001.100.015.381.090.000.000.07
26.301.220.045.631.200.010.010.15
36.621.350.065.901.310.020.020.24
46.971.490.106.191.430.040.050.34
57.341.640.146.491.570.070.070.45
67.731.810.206.811.720.110.110.57
78.152.000.277.161.880.150.160.71
88.602.210.357.532.060.210.220.86
99.092.440.447.922.250.280.301.03
109.602.690.568.342.470.370.391.22
1110.162.980.698.802.710.470.501.44
1210.763.290.859.282.970.600.631.69
1311.413.631.049.813.260.740.781.97
1412.114.021.2610.373.590.920.972.29
1512.864.451.5210.983.941.131.182.65
1613.684.921.8211.634.341.371.433.06
1714.565.452.1812.344.771.661.733.53
1815.526.042.5913.105.262.002.084.07
1916.566.703.0713.935.802.402.484.68
2017.697.443.6414.836.402.872.955.39
2118.928.264.3115.817.073.423.506.20
2220.279.195.0916.887.824.074.137.13
2321.7510.236.0018.058.664.824.888.20
2423.3611.407.0819.329.605.725.759.44
2525.1312.728.3420.7210.666.776.7610.88
2627.0914.219.8422.2511.858.007.9412.54
2729.2415.9011.6023.9413.209.469.3214.47
2831.6117.8113.7025.8014.7211.1910.9416.72
2934.2419.9816.1827.8616.4413.2412.8419.34
3037.1622.4619.1330.1418.4015.6715.0722.40
3140.4125.2822.6532.6720.6318.5617.6925.99
3244.0428.5226.8735.4923.1822.0220.7930.21
3348.0932.2331.9438.6426.0926.1724.4435.19
3452.6436.5038.0442.1629.4431.1528.7741.06
3557.7541.4445.4146.1233.3037.1533.9248.03
3663.5347.1654.3650.5937.7544.4340.0556.31
3770.0753.8065.2755.6342.9253.2747.3866.19
3877.5061.5578.6161.3548.9364.0756.1778.02
3985.9770.6195.0367.8755.9677.3366.7692.25
4095.6681.27116.375.3164.2093.6979.54109.4
41106.893.85140.583.8673.90114.095.05130.2
42119.7108.8172.093.7185.37139.3114.0155.5
43134.6126.5211.6105.199.01171.1137.1186.5
44151.9147.7261.6118.4115.3211.4165.6224.6
45172.3173.3325.3133.9134.9262.7200.8271.7
46196.2204.2407.1152.1158.5328.7244.6330.3
47224.5241.8512.8173.6187.2414.3299.5403.7
48258.3287.9650.7199.3222.3526.5368.7496.0
49298.7344.6832.0229.9265.5674.9456.4613.1
50347.5415.11073266.9319.1873.9568.6762.9

Terzaghi: Nc, Nq closed form, Nγ after Kumbhojkar (1993). General: Nq Reissner (1924), Nc Prandtl (1921). Values computed by GeoTerva with the functions its modules use.

5Worked exampleA strip footing on sand, φ = 30°.

A strip footing B = 2.0 m wide is founded at Df = 1.0 m in sand with c = 0, φ = 30° and γ = 18 kN/m³; the water table is deep. The surcharge at the base level is q = γDf = 18 kPa.

  • Terzaghi: Nq = 22.46, Nγ = 19.13 → qu = 18 × 22.46 + ½ × 18 × 2.0 × 19.13 = 749 kPa.
  • General equation (Vesic’s Nγ, no shape or depth factors): Nq = 18.40, Nγ = 22.40 → qu = 18 × 18.40 + ½ × 18 × 2.0 × 22.40 = 734 kPa.

The general equation is then completed with its depth factors (for Df/B = 0.5) and, for a rectangular footing, its shape factors: the GeoTerva modules do this, step by step, for any footing.

6QuestionsShort answers.

What is Nc when φ = 0?

For an undrained clay (φ = 0), Nq = 1 and Nγ = 0. Nc is 5.70 with Terzaghi’s factors and 5.14 (= π + 2, Prandtl) with the general equation.

Why do the Nγ values differ so much?

Nγ depends on the shape of the failure surface below the base and on the roughness assumed for the base; Terzaghi, Meyerhof, Hansen and Vesic each assumed a different mechanism. At φ = 30° they range from 15.07 (Hansen) to 22.40 (Vesic).

Which factors should I use for a square or circular footing?

The same factors, with the shape correction of the same method: Terzaghi’s 1.3cNc and 0.4γBNγ (square) or 0.3γBNγ (circular), or the shape factors of Meyerhof, Hansen or Vesic with their own Nγ.

The theory behind it