Granular fill reinforced by galvanized steel strips, geotextile sheets or geogrids behind a facing. The module gives the tension of every reinforcement level and checks it for rupture (corrosion or the reduction factors taken off), for pullout beyond the failure surface and for the connection to the facing; then the reinforced block for overturning, eccentricity, sliding and bearing on Meyerhof’s effective width; and the same under an earthquake by Mononobe–Okabe and the inertia of the block. Two procedures: the simplified method of FHWA / AASHTO, or Rankine at every depth.
Vous saisissez
- Height, length and spacing of the reinforcement
- Strips (width, thickness, corrosion) or a geosynthetic (strength, reduction factors)
- Reinforced fill, retained fill and foundation soil
- Dead and live surcharges, a strip load, a seismic coefficient
Vous obtenez
- Tension, rupture and pullout of every level
- The thickness, spacing and length the required factors ask for
- Overturning, eccentricity, sliding and bearing of the block
- The same checks under the earthquake

Le dessin et le verdict après le calcul.